单选题
An AIX 5.3 customer has a Power 780 in a 2-meter (T42) rack. This rack needs to be moved six inches (15cm) to allow under-floor access.   What preparation for moving the rack will result in the least disruption to end-users?()
A

Initiate LPAR fallover to backup systems.

B

Use Live Partition Mobility to move the LPARs to other systems.

C

Use Live Application Mobility to move critical applications to alternate systems.

D

Back up all LPARS to a NIM server and restore them to other LPARs on other systems.


参考答案

参考解析
解析: 暂无解析
更多 “单选题An AIX 5.3 customer has a Power 780 in a 2-meter (T42) rack. This rack needs to be moved six inches (15cm) to allow under-floor access.   What preparation for moving the rack will result in the least disruption to end-users?()A Initiate LPAR fallover to backup systems.B Use Live Partition Mobility to move the LPARs to other systems.C Use Live Application Mobility to move critical applications to alternate systems.D Back up all LPARS to a NIM server and restore them to other LPARs on other systems.” 相关考题
考题 AnAIX5.3customerhasaPower780ina2-meter(T42)rack.Thisrackneedstobemovedsixinches(15cm)toallowunder-flooraccess.Whatpreparationformovingtherackwillresultintheleastdisruptiontoend-users?() A.InitiateLPARfallovertobackupsystems.B.UseLivePartitionMobilitytomovetheLPARstoothersystems.C.UseLiveApplicationMobilitytomovecriticalapplicationstoalternatesystems.D.BackupallLPARStoaNIMserverandrestorethemtootherLPARsonothersystems.

考题 A customer has a p650 on order and plans to put it in a current OEM rack.  They are concerned that the p650 power supply may demand more current than the OEM PDU can provide.  Which planning guide specification would provide the necessary requirements?()A、VoltageB、FrequencyC、Power Source Loading (max)D、Power Source Loading (typical)

考题 An administrator has a single 14U rack.  The administrator needs to install fifteen servers; rack-mounted redundant uninterruptible power supplies (UPSs), a network switch, and a KVM.  Which of the following server types would be BEST suited for this scenario?()A、Blade serversB、Rackmount serversC、Tower serversD、Web servers

考题 Companycom has just purchased a p5 570 with AIX 5.3. The customer would like to add a training LPAR to the system, but no processors are available. All of the partitions are using dedicated resources. The test LPAR is using one processor and has a 90% CPU idle rate. What can be done to setup this training LPAR quickly without disabling their current environment?()A、Use AIX 5.3 which supports micro-partitioning for both the test and training LPARSB、Use DLPAR to move resources from the test LPAR to training when training is activeC、Install Partition Load Manager to share resources between the test and training environmentsD、Install Advanced Power Virtualization and then use micro-partitioning for both the test and training LPARs

考题 A customer is interested in reducing energy consumption and infrastructure consolidation for space. The customer needs a maximum of 14 servers in 7U rack.  Which IBM BladeCenter Chassis should be recommended? ()A、BladeCenter EB、BladeCenter HC、BladeCenter TD、BladeCenter HT

考题 A customer needs to install a rack with six of the x3650 M3 servers with the standard line cords. Each server has redundant power supplies. Which of the following meets this requirement?()A、 Two of DPI C13 Enterprise PDU 39Y8941B、 One of DPI Universal Rack PDU 39Y8951C、 One of DPI C13 Enterprise PDU 39Y8941D、 Two of DPI C19 Enterprise PDU 39Y8948

考题 While installing the equipment for a new two-node cluster, it is discovered that the disk subsystem  Rack has one connection to the power mains. The explanation given was that the disks are to be mirrored between the two disk drawers in the rack and that a failure in either of the disk drawers would simply result in half of the disk being lost.  What can be done to avoid a single point of failure?()   A、 Customize HACMP to overcome quorum issues.B、 Add a second PDU to separate the power connections.C、 Use RAID5 when implementing two IO racks in a HACMP environment.D、 Add another shared disk to each volume group to avoid quorum issues during fallover.

考题 A customer wishes to replace 12 older small UNIX systems.  They are running out of floor space in their data center and any solution must take this into consideration.  Assuming that the applications are supported on all AIX versions, which of the following would best meet the customer’s requirements?()A、A p650 running AIX v5.3B、A p5-550 running AIX v5.3C、A p5-570 running Advanced POWER VirtualizationD、Multiple rack-mounted p615s running dynamic LPAR

考题 A customer is looking for a new file and print server and is considering a 2-socket Intel server with redundant power and hard disk that must fit in the current server rack. With 2U available in the rack, the customer is looking for the best price performance ratio.  Which IBM server will fit the best for this customer?()A、x3200B、x3455C、x3550D、x3650

考题 A customer has requested five rack mounted servers, and a rack. They want redundant power connections. Which of the following is required to meet these requirements?()A、Redundant power supplies on the serversB、Redundant PDUs in the rackC、edundant power supplies in the servers and redundant PDUs in the rackD、Redundant power supplies in the servers, redundant PDUs in the rack, and Active Energy Manager (AEM)

考题 Companycom wants the application server LPAR to communicate with the database LPAR on a p5 590 without using network adapters. What does the customer need to install?()A、VIO ServerB、AIX 5.2 ML4C、Shared Ethernet AdapterD、AIX 5.3 with Advanced Power Virtualization

考题 A customer has several small AIX applications that are expected to grow over the next several years.  The biggest challenge facing the customer is determining the growth rate of the applications and the I/T requirements needed to support the growth.  They are also concerned about the under-utilization of their IT resources.  What should the pSeries technical specialist recommend to address this challenge?()A、Install a p615 per application.B、Install a p650 with AIX 5.2 and dynamic LPAR and CUoD.C、Install the appropriate solution once the requirements are understood.D、Install a POWER5 system with AIX 5.3, Advanced POWER Virtualization, and CoD.

考题 A customer purchased a new IBM xSeries x445.  They already have a non-IBM industry standard rack with 14U of open space that is being considered to house the new server.  The rack houses an existing UPS unit for the entire rack.  Which of the following questions is most important to ensure that the power in the datacenter environment is ready for the initial install?()A、Have optional Fibre Channel and Ethernet switches been installed in the server?B、What is the available kVA value of the UPS?C、Are there sufficient empty socket outlets in the UPS?D、What is the impact on the power consumption of the data center cooling system?

考题 An AIX 5.3 customer has a Power 780 in a 2-meter (T42) rack. This rack needs to be moved six inches (15cm) to allow under-floor access.   What preparation for moving the rack will result in the least disruption to end-users?()A、Initiate LPAR fallover to backup systems.B、Use Live Partition Mobility to move the LPARs to other systems.C、Use Live Application Mobility to move critical applications to alternate systems.D、Back up all LPARS to a NIM server and restore them to other LPARs on other systems.

考题 An IT director needs to deploy 3 partitions, each using dedicated internal boot disk. Which system will support the customer requirement using the least amount of rack space?()A、Power 770 serversB、Power 750 serversC、Power 755 serversD、Power 720 servers

考题 An administrator needs to install a 2U server into a rack. Which of the following shows how much space, in height, needs to be available for the server to fit in the rack?()A、1.75 inches(4.45 cm)B、2.5 inches(6.35 cm)C、3.5 inches(8.89 cm)D、4.25 inches(10.8 cm)

考题 单选题A customer needs to install a rack with six of the x3650 M3 servers with the standard line cords. Each server has redundant power supplies. Which of the following meets this requirement?()A  Two of DPI C13 Enterprise PDU 39Y8941B  One of DPI Universal Rack PDU 39Y8951C  One of DPI C13 Enterprise PDU 39Y8941D  Two of DPI C19 Enterprise PDU 39Y8948

考题 单选题A customer has requested five rack mounted servers, and a rack. They want redundant power connections. Which of the following is required to meet these requirements?()A Redundant power supplies on the serversB Redundant PDUs in the rackC edundant power supplies in the servers and redundant PDUs in the rackD Redundant power supplies in the servers, redundant PDUs in the rack, and Active Energy Manager (AEM)

考题 单选题A customer has a p650 on order and plans to put it in a current OEM rack.  They are concerned that the p650 power supply may demand more current than the OEM PDU can provide.  Which planning guide specification would provide the necessary requirements?()A VoltageB FrequencyC Power Source Loading (max)D Power Source Loading (typical)

考题 单选题A customer wishes to replace 12 older small UNIX systems.  They are running out of floor space in their data center and any solution must take this into consideration.  Assuming that the applications are supported on all AIX versions, which of the following would best meet the customer’s requirements?()A A p650 running AIX v5.3B A p5-550 running AIX v5.3C A p5-570 running Advanced POWER VirtualizationD Multiple rack-mounted p615s running dynamic LPAR

考题 单选题While installing the equipment for a new two-node cluster, it is discovered that the disk subsystem  Rack has one connection to the power mains. The explanation given was that the disks are to be mirrored between the two disk drawers in the rack and that a failure in either of the disk drawers would simply result in half of the disk being lost.  What can be done to avoid a single point of failure?()A  Customize HACMP to overcome quorum issues.B  Add a second PDU to separate the power connections.C  Use RAID5 when implementing two IO racks in a HACMP environment.D  Add another shared disk to each volume group to avoid quorum issues during fallover.

考题 单选题A customer is interested in reducing energy consumption and infrastructure consolidation for space. The customer needs a maximum of 14 servers in 7U rack.  Which IBM BladeCenter Chassis should be recommended? ()A BladeCenter EB BladeCenter HC BladeCenter TD BladeCenter HT

考题 单选题An administrator has a single 14U rack.  The administrator needs to install fifteen servers; rack-mounted redundant uninterruptible power supplies (UPSs), a network switch, and a KVM.  Which of the following server types would be BEST suited for this scenario?()A Blade serversB Rackmount serversC Tower serversD Web servers

考题 单选题A customer is looking for a new file and print server and is considering a 2-socket Intel server with redundant power and hard disk that must fit in the current server rack. With 2U available in the rack, the customer is looking for the best price performance ratio.  Which IBM server will fit the best for this customer?()A x3200B x3455C x3550D x3650

考题 单选题An administrator needs to install a 2U server into a rack. Which of the following shows how much space, in height, needs to be available for the server to fit in the rack?()A 1.75 inches(4.45 cm)B 2.5 inches(6.35 cm)C 3.5 inches(8.89 cm)D 4.25 inches(10.8 cm)

考题 单选题A customer has several small AIX applications that are expected to grow over the next several years.  The biggest challenge facing the customer is determining the growth rate of the applications and the I/T requirements needed to support the growth.  They are also concerned about the under-utilization of their IT resources.  What should the pSeries technical specialist recommend to address this challenge?()A Install a p615 per application.B Install a p650 with AIX 5.2 and dynamic LPAR and CUoD.C Install the appropriate solution once the requirements are understood.D Install a POWER5 system with AIX 5.3, Advanced POWER Virtualization, and CoD.

考题 单选题Companycom has just purchased a p5 570 with AIX 5.3. The customer would like to add a training LPAR to the system, but no processors are available. All of the partitions are using dedicated resources. The test LPAR is using one processor and has a 90% CPU idle rate. What can be done to setup this training LPAR quickly without disabling their current environment?()A Use AIX 5.3 which supports micro-partitioning for both the test and training LPARSB Use DLPAR to move resources from the test LPAR to training when training is activeC Install Partition Load Manager to share resources between the test and training environmentsD Install Advanced Power Virtualization and then use micro-partitioning for both the test and training LPARs