An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1.  If this change is made what is the maximum number of logical ports, across both port groups,  that the IVE adapter can provide? ()
A

 4

B

 16

C

 20

D

 32


参考答案

参考解析
解析: 暂无解析
更多 “单选题An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1.  If this change is made what is the maximum number of logical ports, across both port groups,  that the IVE adapter can provide? ()A  4B  16C  20D  32” 相关考题
考题 AnadministratorhasaPower570indefaultconfigurationwitha4port1GbpsIntegratedVirtualEthernet(IVE)adapter.AnewapplicationrequiresthattheMCSvalueforthefirstportgroupoftheIVEadapterbesetto1.Ifthischangeismadewhatisthemaximumnumberoflogicalports,acrossbothportgroups,thattheIVEadaptercanprovide?()A.4B.16C.20D.32

考题 Acustomerhasa4-corePOWER6570with4partitionsanda2-port1GbpsIntegratedVirtualEthernet(IVE) Adapter.TheyarehavingproblemswiththroughputontheEthernetadapterandwanttoimprove performance.Whichofthefollowingsolutionswillhelpthecustomerwiththisissuefortheleastcostandwith theleastinterruption?()A.Ordera2-port1GbpsEthernetLANadapter.B.Ordera2-port10GbpsEthernetLANadapter.C.UpgradetheIVEadaptertoa4-port1GbpsIVEadapter.D.UpgradetheIVEadaptertoa2-port10GbpsIVEadapter.

考题 Acustomerhasa4-corePOWER6570with4partitionsanda2-port1GbpsIntegratedVirtualEthernet(IVE)Adapter.TheyarehavingproblemswiththroughputontheEthernetadapterandwanttoimproveperformance.Whichofthefollowingsolutionswillhelpthecustomerwiththisissuefortheleastcostandwiththeleastinterruption?()A.Ordera2-port1GbpsEthernetLANadapter.B.Ordera2-port10GbpsEthernetLANadapter.C.UpgradetheIVEadaptertoa4-port1GbpsIVEadapter.D.UpgradetheIVEadaptertoa2-port10GbpsIVEadapter.

考题 A customer has a Power 750 with the following: One processor card with 8 cores enabled, and 64GB RAM installed One GX+ adapter with one I/O drawer attached One 4-port 1Gbps IVE adapter PowerVM Standard Edition. They need to add a GX++ adapter and cable it to an I/O drawer. Which of the following must also be ordered?()A、A second IVE adapterB、A second processor cardC、PowerVM Enterprise EditionD、An additional cable-management arm

考题 An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1.  If this change is made what is the maximum number of logical ports, across both port groups,  that the IVE adapter can provide? ()A、 4B、 16C、 20D、 32

考题 A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A、1B、7C、15D、31

考题 A customer is planning to buy a two enclosure Power 770, and will implement 4 LPARs with the following requirements:Each LPAR must have a private, dedicated connection to the network.The adapter for this network connection must be hot-swappable.The customer wants to minimize the number of I/O slots used. Which of the following fulfills the customer requirements?()A、Two dual-port PCIe adaptersB、A four-port PCIe Ethernet adapterC、Four separate PCIe Ethernet adaptersD、Two embedded Integrated Virtual Ethernet adapters (IVE)

考题 When configuring a dual port gigabit Integrated Virtual Ethernet adapter (IVE), what value must be assigned to Multiple Core Scaling (MCS) to enable 8 logical ports in total? ()A、2B、4C、8D、16

考题 A customer has just purchased an 8-core POWER 570 which has two dual port 1 Gbps  Integrated Virtual Ethernet (IVE) adapters. The customer wants to implement queue pairs (QPs) to take advantage of parallel processing of network traffic to its client logical partitions. Assuming that the system is to utilize the IVEs in both CECs,  which configuration will allow a logical partition to utilize the entire eight cores for network traffic processing?()A、 Set Multiple Core Scaling (MCS) value of the port group to 8 and set multiple core parameter of the client Ethernet adapters to yes.B、 Set Multiple Core Scaling (MCS) value of the port group to 4 and set multiple core parameter of the client Ethernet adapters to yes.C、 Set Multiple Core Scaling (MCS) value of one of the physical port groups to 4 and set multiple core parameter of the client Ethernet adapters to yes.D、 Set Multiple Core Scaling (MCS) value of one of the physical port groups to 8 and set the multiple core parameter of the client Ethernet adapters to yes.

考题 A customer has a 4-core POWER6 570 with 4 partitions and a 2-port 1Gbps Integrated Virtual Ethernet (IVE) Adapter. They are having problems with throughput on the Ethernet adapter and want to improve performance. Which of the following solutions will help the customer with this issue for the least cost and with the least interruption?()A、Order a 2-port 1Gbps Ethernet LAN adapter.B、Order a 2-port 10Gbps Ethernet LAN adapter.C、Upgrade the IVE adapter to a 4-port 1Gbps IVE adapter.D、Upgrade the IVE adapter to a 2-port 10Gbps IVE adapter.

考题 A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()A、Configure 2CFFh combination fibre channel / gigabit Ethernet adaptersB、Configure 1CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterC、Configure 1CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterD、Configure 1CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

考题 A customer has a Power 750 with the following: One processor card with 8 cores enabled, and 64GB RAM installed One GX+ adapter with one I/O drawer attached; One 4-port 1Gbps IVE adapterPowerVM Standard Edition; They need to add a GX++ adapter and cable it to an I/O drawer. Which of the following must also be ordered?()A、A second IVE adapterB、A second processor cardC、PowerVM Enterprise EditionD、An additional cable-management arm

考题 A system administrator is deploying a new POWER5 server. The application requires AIX 5L V5.2.  Which of the following virtualization technologies can be used?()A、DLPARB、Micro-PartitioningC、Virtual StorageD、Virtual Ethernet

考题 An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1. If this change is made, what is the maximum number of logical ports, across both port groups, that the IVE adapter can provide?()A、 4 B、 16 C、 20 D、 32

考题 A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()A、Configure 2 CFFh combination fibre channel / gigabit Ethernet adaptersB、Configure 1 CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterC、Configure 1 CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterD、Configure 1 CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

考题 Which of the following is a true statement when promiscuous mode is enabled on an Integrated Virtual Ethernet?()A、 The physical port can be used as part of a Shared Ethernet Adapter (SEA).B、 All physical ports on the Host Ethernet Adapter (HEA) default to promiscuous mode.C、 Multiple logical ports can be assigned to a physical port if that logical port is in promiscuous mode.D、 All physical ports that belong to the same port group will be set to promiscuous mode on the Host Ethernet Adapter (HEA).

考题 单选题A customer is planning to buy a two enclosure Power 770, and will implement 4 LPARs with the following requirements:Each LPAR must have a private, dedicated connection to the network.The adapter for this network connection must be hot-swappable.The customer wants to minimize the number of I/O slots used. Which of the following fulfills the customer requirements?()A Two dual-port PCIe adaptersB A four-port PCIe Ethernet adapterC Four separate PCIe Ethernet adaptersD Two embedded Integrated Virtual Ethernet adapters (IVE)

考题 单选题A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()A Configure 2 CFFh combination fibre channel / gigabit Ethernet adaptersB Configure 1 CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterC Configure 1 CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterD Configure 1 CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

考题 单选题A customer has a 4-core POWER6 570 with 4 partitions and a 2-port 1Gbps Integrated Virtual Ethernet (IVE) Adapter. They are having problems with throughput on the Ethernet adapter and want to improve performance.  Which of the following solutions will help the customer with this issue for the least cost and with the least interruption?()A Order a 2-port 1Gbps Ethernet LAN adapter.B Order a 2-port 10Gbps Ethernet LAN adapter.C Upgrade the IVE adapter to a 4-port 1Gbps IVE adapter.D Upgrade the IVE adapter to a 2-port 10Gbps IVE adapter.

考题 单选题A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A 1B 7C 15D 31

考题 单选题A customer has a Power 750 with the following: One processor card with 8 cores enabled, and 64GB RAM installed One GX+ adapter with one I/O drawer attached One 4-port 1Gbps IVE adapter PowerVM Standard Edition. They need to add a GX++ adapter and cable it to an I/O drawer. Which of the following must also be ordered?()A A second IVE adapterB A second processor cardC PowerVM Enterprise EditionD An additional cable-management arm

考题 单选题A customer has a Power 750 with the following: One processor card with 8 cores enabled, and 64GB RAM installed One GX+ adapter with one I/O drawer attached; One 4-port 1Gbps IVE adapterPowerVM Standard Edition; They need to add a GX++ adapter and cable it to an I/O drawer. Which of the following must also be ordered?()A A second IVE adapterB A second processor cardC PowerVM Enterprise EditionD An additional cable-management arm

考题 单选题When configuring a dual port gigabit Integrated Virtual Ethernet adapter (IVE), what value must be assigned to Multiple Core Scaling (MCS) to enable 8 logical ports in total? ()A 2B 4C 8D 16

考题 单选题An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1.  If this change is made what is the maximum number of logical ports, across both port groups,  that the IVE adapter can provide? ()A  4B  16C  20D  32

考题 单选题An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1. If this change is made, what is the maximum number of logical ports, across both port groups, that the IVE adapter can provide?()A  4 B  16 C  20 D  32

考题 单选题A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()A Configure 2CFFh combination fibre channel / gigabit Ethernet adaptersB Configure 1CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterC Configure 1CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterD Configure 1CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

考题 单选题Which of the following is a true statement when promiscuous mode is enabled on an Integrated Virtual Ethernet?()A  The physical port can be used as part of a Shared Ethernet Adapter (SEA).B  All physical ports on the Host Ethernet Adapter (HEA) default to promiscuous mode.C  Multiple logical ports can be assigned to a physical port if that logical port is in promiscuous mode.D  All physical ports that belong to the same port group will be set to promiscuous mode on the Host Ethernet Adapter (HEA).

考题 单选题A customer has just purchased an 8-core POWER 570 which has two dual port 1 Gbps  Integrated Virtual Ethernet (IVE) adapters. The customer wants to implement queue pairs (QPs) to take advantage of parallel processing of network traffic to its client logical partitions. Assuming that the system is to utilize the IVEs in both CECs,  which configuration will allow a logical partition to utilize the entire eight cores for network traffic processing?()A  Set Multiple Core Scaling (MCS) value of the port group to 8 and set multiple core parameter of the client Ethernet adapters to yes.B  Set Multiple Core Scaling (MCS) value of the port group to 4 and set multiple core parameter of the client Ethernet adapters to yes.C  Set Multiple Core Scaling (MCS) value of one of the physical port groups to 4 and set multiple core parameter of the client Ethernet adapters to yes.D  Set Multiple Core Scaling (MCS) value of one of the physical port groups to 8 and set the multiple core parameter of the client Ethernet adapters to yes.