When configuring dual VIO servers to connect to SAN based disk in failover mode, what setting must be applied? ()
A

 algorithm = failover

B

 algorithm = round_robin

C

 reserve_policy = no_reserve

D

 reserve_policy = single_path


参考答案

参考解析
解析: 暂无解析
更多 “单选题When configuring dual VIO servers to connect to SAN based disk in failover mode, what setting must be applied? ()A  algorithm = failoverB  algorithm = round_robinC  reserve_policy = no_reserveD  reserve_policy = single_path” 相关考题
考题 Which RADIUS configuration command implements a primary/backup scenario for multiple servers?() A.radius algorithm directB.radius algorithm backupC.radius algorithm primaryD.radius algorithm round-robin

考题 WhenconfiguringdualVIOserverstoconnecttoSANbaseddiskinfailovermode,whatsettingmustbeapplied?() A.algorithm=failoverB.algorithm=round_robinC.reserve_policy=no_reserveD.reserve_policy=single_path

考题 A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()A、ImplementPowerHA SystemMirror on both VIO servers.B、ConfigureEtherchannel between the client LPARs and the two VIO serversC、Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.D、Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

考题 What restrictions apply to using virtual Ethernet within a cluster containing VIO clients?()A、IPAT via Aliasing must be usedB、IPAT via Replacement must be usedC、Resilience must be provided by the use of dual VIO serversD、Hardware Address Takeover (HWAT) must be used to ensure a consistent virtual MAC address

考题 After rebooting one Virtual IO (VIO) server in a redundant environment, the following command output from the client partition shows that the path to the shared disk from the rebooted VIO server remains in a failed state.  Vio_client1# lspath Failed hdisk0 vscsi0 Enabled hdisk0 vscsi1 What must the administrator do to ensure that the path is automatically restored when a VIO server is brought back into service? ()A、 On both VIO servers, modify the inittab making chdev the last command, so that they will start during VIO server reboot.B、 On both VIO servers, change the following parameters and reboot each of them in turn    hcheck_interval =60 hcheck_mode=interactiveC、 On client logical partition, modify the inittab making chdev the last command, so that they will start during client partition reboot.D、 On the client logical partition, change the following parameters and reboot the client    hcheck_interval =60hcheck_mode=interactive

考题 When configuring a dual port gigabit Integrated Virtual Ethernet adapter (IVE), what value must be assigned to Multiple Core Scaling (MCS) to enable 8 logical ports in total? ()A、2B、4C、8D、16

考题 A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()A、Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAsB、Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.C、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.D、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.

考题 A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down.  Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()A、Implement PowerHA SystemMirror on both VIO servers.B、Configure Etherchannel between the client LPARs and the two VIO serversC、Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.D、Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

考题 A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()A、Implement PowerHA SystemMirror on both VIO servers.B、Configure Etherchannel between the client LPARs and the two VIO servers.C、Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.D、Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

考题 A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()A、An HMC is required for dual VIO servers.B、Dual VIO servers require a split backplane.C、A dual VIO enablement code must be entered from the ASMI interface.D、The second VIO server must be created using the IVM command line interface.

考题 Which RADIUS configuration command implements a primary/backup scenario for multiple servers?()A、radius algorithm directB、radius algorithm backupC、radius algorithm primaryD、radius algorithm round-robin

考题 You want to use RMAN to create compressed backups.Which statement is true about the compression algorithms that RMAN can use?()A、The BZIP2 compression algorithm consumes more CPU resources than the ZLIB compression algorithm.B、The ZLIB compression algorithm consumes more CPU resources than the BZIP2 compression algorithm.C、The ZLIB compression algorithm provides maximum compression and produces smaller backups than the BZIP2 compression algorithm.D、Only the BZIP2 compression algorithm can be used to make compressed backups to disk.

考题 You need to recommend a solution for configuring the Web servers. The solution must meet the  company’s technical requirements.What should you include in the recommendations?()A、Active Directory Lightweight Directory Services (AD LDS)B、Failover ClusteringC、HTTP redirectionD、IIS Shared Configuration

考题 When configuring Shared Ethernet Adapter (SEA) failover between two VIO servers,  which of the following attributes must have a different value on both VIO servers?()A、 HA ModeB、 Trunk priorityC、 Control ChannelD、 Default VLAN ID

考题 When configuring dual VIO servers to connect to SAN based disk in failover mode, what setting must be applied? ()A、 algorithm = failoverB、 algorithm = round_robinC、 reserve_policy = no_reserveD、 reserve_policy = single_path

考题 单选题What restrictions apply to using virtual Ethernet within a cluster containing VIO clients?()A IPAT via Aliasing must be usedB IPAT via Replacement must be usedC Resilience must be provided by the use of dual VIO serversD Hardware Address Takeover (HWAT) must be used to ensure a consistent virtual MAC address

考题 单选题After rebooting one Virtual IO (VIO) server in a redundant environment, the following command output from the client partition shows that the path to the shared disk from the rebooted VIO server remains in a failed state.  Vio_client1# lspath Failed hdisk0 vscsi0 Enabled hdisk0 vscsi1 What must the administrator do to ensure that the path is automatically restored when a VIO server is brought back into service? ()A  On both VIO servers, modify the inittab making chdev the last command, so that they will start during VIO server reboot.B  On both VIO servers, change the following parameters and reboot each of them in turn    hcheck_interval =60 hcheck_mode=interactiveC  On client logical partition, modify the inittab making chdev the last command, so that they will start during client partition reboot.D  On the client logical partition, change the following parameters and reboot the client    hcheck_interval =60hcheck_mode=interactive

考题 单选题You want to use RMAN to create compressed backups.Which statement is true about the compression algorithms that RMAN can use?()A The BZIP2 compression algorithm consumes more CPU resources than the ZLIB compression algorithm.B The ZLIB compression algorithm consumes more CPU resources than the BZIP2 compression algorithm.C The ZLIB compression algorithm provides maximum compression and produces smaller backups than the BZIP2 compression algorithm.D Only the BZIP2 compression algorithm can be used to make compressed backups to disk.

考题 单选题When configuring a dual port gigabit Integrated Virtual Ethernet adapter (IVE), what value must be assigned to Multiple Core Scaling (MCS) to enable 8 logical ports in total? ()A 2B 4C 8D 16

考题 单选题A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()A Implement PowerHA SystemMirror on both VIO servers.B Configure Etherchannel between the client LPARs and the two VIO servers.C Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.D Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

考题 单选题A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()A ImplementPowerHA SystemMirror on both VIO servers.B ConfigureEtherchannel between the client LPARs and the two VIO serversC Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.D Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

考题 单选题A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down.  Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()A Implement PowerHA SystemMirror on both VIO servers.B Configure Etherchannel between the client LPARs and the two VIO serversC Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.D Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

考题 单选题Which RADIUS configuration command implements a primary/backup scenario for multiple servers?()A radius algorithm directB radius algorithm backupC radius algorithm primaryD radius algorithm round-robin

考题 单选题When configuring Shared Ethernet Adapter (SEA) failover between two VIO servers,  which of the following attributes must have a different value on both VIO servers?()A  HA ModeB  Trunk priorityC  Control ChannelD  Default VLAN ID

考题 单选题A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()A Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAsB Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.C Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.D Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.

考题 单选题You are evaluating the use of failover clusters with Cluster Shared Volumes (CSV) for the database servers. You need to recommend which hardware must be purchased. What should you include in the recommendation?()A a WAN acceleratorB a hardware load balancerC Network Attached Storage (NAS)D a Storage Area Network (SAN)

考题 单选题When configuring dual VIO servers to connect to SAN based disk in failover mode, what setting must be applied? ()A  algorithm = failoverB  algorithm = round_robinC  reserve_policy = no_reserveD  reserve_policy = single_path

考题 单选题A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()A An HMC is required for dual VIO servers.B Dual VIO servers require a split backplane.C A dual VIO enablement code must be entered from the ASMI interface.D The second VIO server must be created using the IVM command line interface.