网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)

A System p administrator in a manufacturing customer plans to migrate an AIX 5.2 system to a new LPAR on an existing System p using VIOS.  Which of the following must be completed prior to this migration ()

  • A、Upgrade system firmware to latest level
  • B、Upgrade to AIX 5.3
  • C、Upgrade HMC to version 6.1
  • D、Convert rootvg filesystems to JFS2

参考答案

更多 “ A System p administrator in a manufacturing customer plans to migrate an AIX 5.2 system to a new LPAR on an existing System p using VIOS.  Which of the following must be completed prior to this migration ()A、Upgrade system firmware to latest levelB、Upgrade to AIX 5.3C、Upgrade HMC to version 6.1D、Convert rootvg filesystems to JFS2” 相关考题
考题 A System p administrator plans to install a new system with AIX 5.3 TL5 using a NIM server.  Which of the following provide post install diagnostics()A、SPOTB、lpp_sourceC、mksysbD、install CD

考题 A system must be upgraded from AIX 5.1 to 5.2.  Which of the following scheduling processes should be performed? ()A、 Schedule enough down time to backup, upgrade and reboot. B、 Backup, upgrade, then schedule enough down time to reboot the system. C、 Backup, then schedule enough down time to upgrade and reboot the system. D、 No scheduling processes are necessary because no down time is required.

考题 A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

考题 A system administrator completed an upgrade of the maintenance level of their AIX system. Which of the following commands should be run to verify that the operating system is in a consistent state?()A、instfix -iB、lslpp -lC、lppchk -vD、oslevel -r

考题 A Power Systems customer would like to upgrade their HMC to the latest version of software tosupport a new hardware feature. What resource will help identify dependencies for firmware and system software for their upgrade?()A、ITSO RedbooksB、Facts and FeaturesC、System Planning ToolD、Fix Level Recommendation Tool

考题 Company.com has ordered an 8-way p5-570 and plans to deploy four AIX 5L v5.3 LPARs. The pre-installation system design has all eight processors being placed in the shared processor pool, and four Micro-Partitions being assigned resources from the pool. Prior to the implementation of the system, the customer informs the technical specialist that one of the applications is only supported on AIX 5L 5.2. Which of the following changes to the system design should the technical specialist make to accommodate this change?()A、Create all the partitions as AIX 5.2, each having two dedicated processors.B、Purchase a system with two additional processors that can be assigned to the AIX 5.2 Partition.C、Specify an AIX 5.2 partition using dedicated processors, reducing the number of processors in the shared pool.D、Use the virtual I/O server to manage the disks and network connections removing the need for different levels of device drivers.

考题 Prior to implementing an LPAR system, which of the following needs to be done?()A、A graphics monitor must be attached to the serverB、Cluster System Management (CSM) software must be installedC、The LPAR system must have an Hardware Management Console (HMC) connectedD、Each LPAR must be configured with a CDROM for operating system installation

考题 A customer is planning to migrate a financial application to a 12-way p5-570 system with 96GB of memory.  The application data is stored on an ESS Model 800 attached to a p670 server with AIX 5.2.  They will have a short outage window to perform the data migration.  What is the quickest way to move all the data stored on the attached ESS from the p670 to the new p5-570?()A、Use rsync to synchronize the data across servers.B、Use exportvg and importvg to move the data to the target system.C、Use NFS to copy the data from the source system to the target system.D、Backup the data from the source system and restore to the target system.

考题 A production system needs to be upgraded from AIX V5.2 to AIX V5.3. All system logs and users need to be saved.  Which installation method will accomplish the upgrade()A、Update InstallationB、Migration InstallationC、Preservation InstallationD、Mirror rootvg prior to a Preservation Installation

考题 A system administrator has just finished upgrading a system to AIX 5.2. If there are future problems, the system administrator would like to add an entry to the AIX errorlog to record this event. Which of the following commands can be issued for this purpose?()A、/usr/bin/errmsg "System upgraded to AIX 5.2"B、/usr/bin/errlog "System upgraded to AIX 5.2"C、/usr/bin/errupdate "System upgraded to AIX 5.2"D、/usr/bin/errlogger "System upgraded to AIX 5.2"

考题 An administrator issued a command to update thefirmware of an Ethernet adapter on a partitioned system, but received an error. What is the most likely cause of the problem?()A、The adapter must be taken offline prior to the firmware update.B、The system has not been rebooted since the adapter was added to the LPAR.C、The adapter must be assigned to the service partition prior to updating the firmware.D、The adapter must be dynamically removed from the LPAR prior to updating thefirmware.

考题 A customer needs a system supporting four partitions, each with the following requirements: ? 0.6 1.65GHz processors ? 2GB memory ? AIX 5.2 They also need the ability to grow the system in the future.  Which pSeries system would be positioned best to meet this customer’s requirements?()A、p5-550 with the Advanced POWER Virtualization feature and AIX 5.2B、p5-550 with the POWER5 processor technology and AIX 5.2C、p5-570 with the Advanced POWER Virtualization feature and AIX 5.3D、p5-570 with the POWER5 processor technology and AIX 5.2

考题 An administrator issued a command to update the firmware of an Ethernet adapter on a partitioned system, but received an error. What is the most likely cause of the problem?()A、The adapter must be taken offline prior to the firmware update.B、The system has not been rebooted since the adapter was added to the LPAR.C、The adapter must be assigned to the service partition prior to updating the firmware.D、The adapter must be dynamically removed from the LPAR prior to updating the firmware.

考题 A System p distribution customer is very concerned about Reliability, Availability and  Serviceability (RAS). They are planning to install several p6 servers in their facilities and want to be able to move an LPAR from one System p to another.  Which of the following would accomplish this()A、System p servers using similar SAN storageB、System p servers must share an HMCC、System p servers must have the same level HMCD、System p servers with VIOS

考题 A customer currently has five partitioned POWER4 systems and is adding new systems.  When the pSeries technical specialist introduces the first p5 system with CoD into this environment, how should the HMC be handled?()A、Order a new HMC to support the p5 system.B、Attach the new p5 system to the existing HMC.C、Upgrade the existing HMC to accommodate both the POWER4 and p5 systems.D、Do nothing.  This system does not require an HMC.

考题 A System p administrator needs to upgrade a system from AIX 5.2 to AIX 5.3.  Which of the following installation methods would minimize downtime()A、Migration installationB、Partition MobilityC、alt_disk_installD、update_all smit fastpath and reboot during the next scheduled outage

考题 A client tried to upgrade the system firmware on a p5 590, but it failed. What is the minimum requirement to update the system firmware from the HMC if inventory scout is already installed?()A、A public internet connectionB、All of the Logical Partitions need to be activeC、One partition must be configured with Service AuthorityD、A local Repository must be configured prior to the update

考题 单选题A System p administrator needs to upgrade a system from AIX 5.2 to AIX 5.3.  Which of the following installation methods would minimize downtime()A Migration installationB Partition MobilityC alt_disk_installD update_all smit fastpath and reboot during the next scheduled outage

考题 单选题Prior to implementing an LPAR system, which of the following needs to be done?()A A graphics monitor must be attached to the serverB Cluster System Management (CSM) software must be installedC The LPAR system must have an Hardware Management Console (HMC) connectedD Each LPAR must be configured with a CDROM for operating system installation

考题 单选题A system administrator has just finished upgrading a system to AIX 5.2. If there are future problems, the system administrator would like to add an entry to the AIX errorlog to record this event. Which of the following commands can be issued for this purpose?()A /usr/bin/errmsg System upgraded to AIX 5.2B /usr/bin/errlog System upgraded to AIX 5.2C /usr/bin/errupdate System upgraded to AIX 5.2D /usr/bin/errlogger System upgraded to AIX 5.2

考题 单选题A System p distribution customer is very concerned about Reliability, Availability and  Serviceability (RAS). They are planning to install several p6 servers in their facilities and want to be able to move an LPAR from one System p to another.  Which of the following would accomplish this()A System p servers using similar SAN storageB System p servers must share an HMCC System p servers must have the same level HMCD System p servers with VIOS

考题 单选题An administrator issued a command to update thefirmware of an Ethernet adapter on a partitioned system, but received an error. What is the most likely cause of the problem?()A The adapter must be taken offline prior to the firmware update.B The system has not been rebooted since the adapter was added to the LPAR.C The adapter must be assigned to the service partition prior to updating the firmware.D The adapter must be dynamically removed from the LPAR prior to updating thefirmware.

考题 单选题A System p administrator in a manufacturing customer plans to migrate an AIX 5.2 system to a new LPAR on an existing System p using VIOS.  Which of the following must be completed prior to this migration ()A Upgrade system firmware to latest levelB Upgrade to AIX 5.3C Upgrade HMC to version 6.1D Convert rootvg filesystems to JFS2

考题 单选题A system administrator has a pSeries p5-520 2-way with AIX 5L V5.2 with a peak utilization of 50%. There is a request to add a new Web server for a small department. Which of the following solutions is the best fit for this environment?()A Create a dedicated LPAR for the existing workload and a Micro-Partition for the Web server. B Create a dedicated LPAR for the existing workload and a dedicated LPAR for the Web server.C Create a Micro-Partition for the existing workload and a dedicated LPAR for the Web server.D Create a Micro-Partition for the existing workload and a Micro-Partition for the Web server.

考题 单选题An administrator issued a command to update the firmware of an Ethernet adapter on a partitioned system, but received an error. What is the most likely cause of the problem?()A The adapter must be taken offline prior to the firmware update.B The system has not been rebooted since the adapter was added to the LPAR.C The adapter must be assigned to the service partition prior to updating the firmware.D The adapter must be dynamically removed from the LPAR prior to updating the firmware.

考题 单选题A client tried to upgrade the system firmware on a p5 590, but it failed. What is the minimum requirement to update the system firmware from the HMC if inventory scout is already installed?()A A public internet connectionB All of the Logical Partitions need to be activeC One partition must be configured with Service AuthorityD A local Repository must be configured prior to the update

考题 单选题A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A  Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B  Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C  Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D  Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.