网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
Portable fire extinguishers must be provided for the cargo tank area of an unmanned tank barge().
A

only when fully loaded

B

if one or more tanks are full

C

when transferring cargo

D

only when the barge is being towed


参考答案

参考解析
解析: 暂无解析
更多 “单选题Portable fire extinguishers must be provided for the cargo tank area of an unmanned tank barge().A only when fully loadedB if one or more tanks are fullC when transferring cargoD only when the barge is being towed” 相关考题
考题 Portable carbon dioxide fire extinguishers should be sent ashore to be rechargedA.when the remaining charge volume is less than 90 percent of the required volumeB.at each inspection for certificationC.at each annual inspectionD.when the weight loss exceeds 10% of weight of charge

考题 If the Shipowner has agreed to receive deck cargo, ________ must contribute to the loss, provided the owner of the jettisoned goods is the sole cargo owner.A.the shipB.the ship and the freightC.the freightD.neither the ship nor the freight

考题 The required number and type of hand portable fire extinguishers for staterooms on cargo vessels is ______.A.one A-IB.one B-IC.one C-ID.none required

考题 You are on a cargo vessel carrying toluol in bulk in portable tanks. Which is a requirement for pumping the toluol?A.Hose connections to the tank must be made with a minimum of three boltsB.There must be water pressure on the fire mainC.You must shut down if another vessel comes alongsideD.If transferring at anchor,you must display a red flag by day and a red light at night

考题 To determine the number of portable fire extinguishers required on an inspected vessel,you should check the ______.A.hot work permitB.Certificate of InspectionC.Safety of Life at Sea CertificateD.station bill

考题 Oceangoing dry bulk cargo vessels over 1000 GT must have approved combination-type fire nozzles at all ______.A.Fire stations aboard the vessel,except for those in open deck areas weatherdeck and cargo hold fire stationsB.Interior fire stationsC.Engine room fire stationsD.All of the above

考题 You are on a tanker designed to carry molten sulfur.Which statement is TRUE ________.A.There must be two portable toxic vapor detectors on boardB.The cargo tank ventilation system must maintain the H2S vapor concentration at 1.85% or more by volumeC.Cargo temperature may be taken by portable thermometersD.The pressure in the heating coils in the tanks must be less than that of the cargo exerted on them

考题 Your tanker is carrying a cargo of styrene.Which of the following is NOT a requirement for carriage of this cargo ________.A.P/V valves with galvanized parts must be replacedB.Authorization to carry styrene must be endorsed on the Certificate of InspectionC.You must have a Certificate of Inhibition provided by the shipperD.The cargo tank heating coils must be blanked off

考题 A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the ______.A.Fire hose might be damaged by cargo operationsB.Vessel is in portC.Fire-main system is not chargedD.Fire pumps are used for purposes other than supplying water to the fire main

考题 All portable fire extinguishers must be capable of being ______.A.carried by hand to a fireB.carried or rolled to a fireC.recharged in the fieldD.used on class “B” fire

考题 Each hand portable fire extinguisher on M/V Utopia must be marked with______.A.the date that it was installed on the unitB.the names of the individuals qualified to use itC.the name of the unit on which it is locatedD.an identification number different from other extinguishers on the unit

考题 Carry ()(手提灭火器)to the fire place.A、extinguishersB、portable extinguishersC、dry foam extinguishersD、CO2 extinguishers

考题 单选题You are on a cargo vessel carrying toluol in bulk in portable tanks. Which is a requirement for pumping the toluol? ()A Hose connections to the tank must be made with a minimum of three boltsB There must be water pressure on the fire mainC You must shut down if another vessel comes alongsideD If transferring at anchor,you must display a red flag by day and a red light at night

考题 单选题Oceangoing dry bulk cargo vessels over 1000 GT must have approved combination-type fire nozzles at all().A fire stations aboard the vessel,except for those in open deck areas weatherdeck and cargo hold fire stationsB interior fire stationsC engine room fire stationsD all of the above

考题 单选题Foam-type portable fire extinguishers are more usefull in combating fires involving().A solid materials such as wood or bales of fiberB inflammable liquidsC electrical equipmentD metallic solids

考题 单选题Portable foam type fire extinguishers are most effective on().A mattress firesB oil firesC wood firesD All of the above

考题 单选题Each hand portable,semi-portable and fixed fire extinguishing unit on a ship must be tested and inspected at least once every().A six weeksB six monthsC twelve monthsD two years

考题 单选题You are on a container vessel. What concerning the handling and stowage of containerized hazardous materials is TRUE?().A Open-bed containers may be used to transport hazardous materials if the cargo is properly securedB A portable cargo tank of a flammable,cryogenic liquid may not be in transit for a period exceeding its marked rated holding time unless the liquid is inhibitedC A portable cargo tank containing a cryogenic liquid must be shipped on deck unless forced ventilation is provided to the tween-decksD A container loaded with packages of tear gas would display a placard reading Irritant

考题 单选题The FIRST course of action in fighting a fire in a cargo or fuel oil tank is to ().A secure all openings to the tankB discharge an initial charge of CO2 with a hand portable extinguisherC direct a fire hose into the tank and energize the fire mainD spray the tank boundaries with a fire hose to promote cooling

考题 单选题Portable carbon dioxide fire extinguishers should be sent ashore to be recharged ().A when the remaining charge volume is less than 90 percent of the required VOLUMEB at each inspection for certificationC at each annual inspectionD when the weight loss exceeds 10% of weight of charge

考题 单选题The required number and type of hand portable fire extinguishers for staterooms on cargo vessels is().A one A-IB one B-IC one C-ID none required

考题 单选题The soda-acid portable extinguishers must be discharged and refilled ().A every six monthsB every yearC every one and half yearD every two years

考题 单选题All portable fire extinguishers must be capable of being().A carried by hand to a fireB carried or rolled to a fireC recharged in the fieldD used on class 'B' fires

考题 单选题Which types of portable fire extinguishers are designed for use on electrical fires?()A Dry chemical and carbon dioxideB Foam (stored pressure) and soda-acidC Carbon dioxide and foam (stored pressure)D Dry chemical and soda-acid

考题 单选题Each hand portable fire extinguisher on a ship must be marked with().A the name of the unit on which it is locatedB the date that it was installed on the unitC the names of the individuals qualified to use itD an identification number different from other extinguishers on the unit

考题 单选题Portable CO2 fire extinguishers should NOT be used to inert a space containing flammable liquids due to the danger of().A the CO2 being inhaled by personnelB reflash of burning liquidsC vapor condensation on the extinguisherD the discharge causing a static spark

考题 单选题All portable fine extinguishers must be capable of being().A carried by hand to a fireB carried or rolled to a fireC recharged in the fieldD used on class B fires