Water level controllers of the boiler must be kept operable to protect external steam-using plant from water “()” danger.
A
carry off
B
carry down
C
carry on
D
carry over
参考答案
参考解析
解析:
暂无解析
更多 “单选题Water level controllers of the boiler must be kept operable to protect external steam-using plant from water “()” danger.A carry offB carry downC carry onD carry over” 相关考题
考题
The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure
考题
The water level in the gauge glass when a boiler is operating is _____ when the boiler is shut down.A.lower thanB.higher thanC.belowD.equal to
考题
The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler()
A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low
考题
The water level showing in a boiler water gauge glass is usually ( ) duringworking.A.higher than the actual drum water levelB.equal to the actual drum water levelC.increasing due to steam condensation in the glassD.lower than actual drum wafer level
考题
what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .
考题
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity
考题
If the sump ______were to rise this would indicate water leakage into the oil and an investigation into the cause must be made.A.temperatureB.viscosityC.leverD.level
考题
单选题You should frequently compare drum-mounted and remote-reading water level indicators() between these have contributed to failures because of overheating through shortage of water, when a boiler was being oil-fired.A
descriptionsB
discrepanciesC
differentD
deflections
考题
单选题The water level of an exhaust gas boiler which is independent of the auxiliary boiler and just as the extra heating surface of it ()A
will be modulated in proportionB
will be modulated in proportion and integralC
will be modulated in proportion and differentialD
will not be modulated at all
考题
单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()A
natural circulation of the water in the water tube boiler is better than that in the fire tube boilerB
for the same output the water tube boiler will carry less mass of water compared with the fire tube boilerC
the water tube boiler will cost shorter time for steam raisingD
the water tube boiler require lower skill in operating and maintaining
考题
单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().A
operating the boiler at less than normal water levelB
installing fins on the firesides of water-tubesC
increasing the amount of excess air to the burnersD
treating the boiler water with chemical oxygen scavengers
考题
单选题The correct procedure for giving an auxiliary boiler a bottom blow, is to begin()A
when the boiler has been secured long enough for most solids to settleB
when the boiler has been cooled to ambient temperatureC
only after raising the water level to within 0~5 inch of the high water cutout onlyD
after bypassing the low pressure
考题
单选题When the boiler load returns to normal, the drum pressure will rise and steam bubble formation will reduce, causing a fall in water level This is known as ().A
swellB
shrinkageC
flash offD
lack of water
考题
单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()A
firing for extended periods in the low fire modeB
overheating, due to waterside depositsC
varying the water level above the crown sheetD
carrying excessive alkalinity in the boiler water
考题
单选题During the diesel engine running, the water level of FW expansion tank should normally kept in the () level of glass tube.A
the highestB
above 3/4C
1/2-3/4D
the lowest
考题
单选题When preparing an engine for water temperature()A
should be kept at a proper level by a coolerB
should be raised to about 80℃ by a heaterC
should be raised graduallyD
should be lowered to about 60℃
考题
单选题A feed pump for an auxiliary boiler might lose suction if the ().A
boiler water level is lowB
feedwater is too hotC
boiler steam demand is lowD
feedwater is too cold
考题
单选题For proper operation, auxiliary boiler feed water must have which of the following characteristics?()A
High oxygen concentrationB
Low pHC
Proper alkalinityD
All of the above
考题
单选题Water level controllers of the boiler must be kept operable to protect external steam-using plant from water “()” danger.A
carry offB
carry downC
carry onD
carry over
考题
单选题The water level in a steaming auxiliary boiler will always ()A
rise when the steam pressure is increasedB
remain constant as long as the feed pump operatesC
fall when the steam pressure is decreasedD
vary as the steam demand changes
考题
单选题The water level showing in a boiler water gauge glass is usually () during working.A
higher than the actual drum water levelB
equal to the actual drum water levelC
increasing due to steam condensation in the glassD
lower than actual drum water level
考题
单选题During the diesel engine running, the water level of F.W expansion tank should normally kept in the () level of glass tube.A
the highestB
above 3/4C
1/2 -3/4D
the lowest
考题
单选题If in doubt as to the true water level when a boiler is being oil-fired, you should ().A
take no measuresB
extinguish the fire as soon as possibleC
feed water to the boilerD
open the blow down valve
考题
单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()A
precipitate silica from solutionB
reduce corrosion in the heating coilC
prevent clogging and erosion in the coilD
maintain zero water hardness
考题
单选题When steam is being raised on a boiler, the water level will normally ().A
drop as the boiler warms upB
rise as the boiler warms upC
remain unchanged until the boiler is hot enoughD
rise and fall with the steam demand
考题
单选题The water level in the gauge glass when a boiler is operating is () when the boiler is shut down.A
lower thanB
higher thanC
belowD
equal to
考题
单选题When a boiler is operating, the water level in the gauge glass reads () when the boiler is shut down.A
lower thanB
higher thanC
as much asD
the same as
考题
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A
high steam pressure in the boilerB
abnormally high feed water temperatureC
abnormally high boiler water temperatureD
steam demand exceeding feed pump capacity
热门标签