You are deploying two core switches, one in each building, 50 km away from each other. The cross-connection between them will be a Layer 2 2-gigabit EtherChannel with an 802.1Q trunk. You configured it correctly but the link does not come up. The port is in the "admin up" state, and the line protocol is in the "down" state. The fiber link is OK. What would be the most likely reason for the link not to come up?()
A
The switches are not the same model.
B
You are not using the correct SFP.
C
You are not using correct optical media converters.
D
Configuration should be modified, because the distance is longer.
参考答案
参考解析
解析:
暂无解析
更多 “单选题You are deploying two core switches, one in each building, 50 km away from each other. The cross-connection between them will be a Layer 2 2-gigabit EtherChannel with an 802.1Q trunk. You configured it correctly but the link does not come up. The port is in the "admin up" state, and the line protocol is in the "down" state. The fiber link is OK. What would be the most likely reason for the link not to come up?()A The switches are not the same model.B You are not using the correct SFP.C You are not using correct optical media converters.D Configuration should be modified, because the distance is longer.” 相关考题
考题
To which switch or switches should you provide redundant links in order to achieve high availability with reliable fast convergence in the enterprise campus?()
A. to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 2 linkB. to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 3 linkC. to two core switches from redundant distribution switches connected with a Layer 2 linkD. to two core switches from redundant distribution switches connected with a Layer 3 linkE. to two core switches running Cisco NSF and SSO from two redundant distribution switches running Cisco NSF and SSO
考题
You have just created a new VLAN on your network for inter-VLAN routing. What is one step that you should include in your VLAN-based implementation and verification plan?()A、Verify that different native VLANs exist between two switches for security purposes.B、Verify that the switch is configured to allow for trunking on the switch ports.C、Verify that each switch port has the proper IP address space assigned to it for the new VLAN. D、Verify that the VLAN virtual interface has been correctly created and enabled.
考题
You enabled CDP on two Cisco Routers which are connected to each other. The Line and Protocol statusfor the interfaces on both routers show as UP but the routers do not see each other a CDP neighbors.Which layer of the OSI model does the problem most likely exist?()A、PhysicalB、SessionC、ApplicationD、Data-LinkE、Network
考题
You are deploying two core switches, one in each building, 50 km away from each other. The cross-connection between them will be a Layer 2 2-gigabit EtherChannel with an 802.1Q trunk. You configured it correctly but the link does not come up. The port is in the "admin up" state, and the line protocol is in the "down" state. The fiber link is OK. What would be the most likely reason for the link not to come up? ()A、 The switches are not the same modelB、 You are not using the correct SFPC、 You are not using correct optical media convertersD、 Configuration should be modified, because the distance is longer
考题
To which switch or switches should you provide redundant links in order to achieve high availability with reliable fast convergence in the enterprise campus?()A、 to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 2 linkB、 to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 3 linkC、 to two core switches from redundant distribution switches connected with Layer 2 linkD、 to two core switches from redundant distribution switches connected with Layer 3 linkE、 to two core switches running Cisco NSF and SSO from two redundant distribution switches running Cisco NSF and SSO
考题
You have just created a new VLAN on your network. What is one step that you should include in your VLAN based implementation and verification plan? ()A、Verify that different native VLANs exist between two switches for security purposes.B、Verify that the VLAN was added on all switches with the use of the show vlan command. C、Verify that the switch is configured to allow for trunking on the switch ports.D、Verify that each switch port has the correct IP address space assigned to it for the new VLAN.
考题
You need to connect two Company core switches via an ISL trunk. Which statement is true regarding the configuration of ISL trunks? ()A、 A Catalyst switch cannot have ISL and IEEE 802.1q trunks enabled.B、 All Catalyst switches support ISL trunking.C、 A Catalyst switch will report giants if one side is configured for ISL while the other side is not.D、 ISL trunking requires that native VLANs match.E、 None of the other alternatives apply
考题
You have a trunk link operating between two switches and you’re experiencing problems withframes leaking between the two VLANs. Each switch has identical modules, software revisionsand VLAN configuration information. Spanning tree protocol is disabled on all VLANs. What isprobably causing this problem?()A、The link is using IEEE 802.1Q protocolB、The link is using IEEE 802.1E protocolC、Spanning tree is disabledD、Not enough information to determineE、The native VLAN information is identical at each end of the linkF、The native VLAN information is different at each end of the link
考题
You are configuring an 802.1Q trunk between a Layer 2 switch and a firewall. You read in the documentation that the best way to set up a trunk is to set the port as dynamic desirable. The trunk is not coming up. Which one of these options would be a valid explanation? ()A、The firewall does not support Cisco Discovery Protocol. You should set the switchport trunk mode ONB、The firewall does not support Cisco Discovery Protocol. You should set the switchport trunk mode to OFFC、The firewall does not support Cisco Discovery Protocol. You should set the switchport trunk mode asauto.D、The firewall does not support DTP. You should set the switchport trunk mode to ON
考题
You are deploying two core switches, one in each building, 50 km away from each other. The cross-connection between them will be a Layer 2 2-gigabit EtherChannel with an 802.1Q trunk. You configured it correctly but the link does not come up. The port is in the "admin up" state, and the line protocol is in the "down" state. The fiber link is OK. What would be the most likely reason for the link not to come up?()A、The switches are not the same model.B、You are not using the correct SFP.C、You are not using correct optical media converters.D、Configuration should be modified, because the distance is longer.
考题
You have just created a new VLAN on your network. What is one step that you should include in your VLAN-based implementation and verification plan? ()A、Verify that trunked links are configured to allow the VLAN traffic.B、Verify that the switch is configured to allow for trunking on the switch ports.C、Verify that each switch port has the correct IP address space assigned to it for the new VLAN.D、Verify that different native VLANs exist between two switches for security purposes.
考题
The Company core switches use 802.1Q trunks to connect to each other. How does 802.1Q trunking keep track of multiple VLANs? ()A、 It tags the data frame with VLAN information and recalculates the CRC valueB、 It encapsulates the data frame with a new header and frame check sequenceC、 It modifies the port index of a data frame to indicate the VLAND、 It adds a new header containing the VLAN ID to the data frameE、 None of the other alternatives apply
考题
Your company has 10 offices. The offices connect to the Internet by using a WAN link. The offices connect to each other by using a VPN connection. An Active Directory site exists for each office. You plan to deploy Exchange Server 2010. Each site will contain two Exchange Server 2010 servers. You need to recommend the placement of domain controllers and global catalog servers to meet thefollowing requirements: .Minimize the number of domain controllers .Must be able to deliver e-mail messages between users of the same office, if a domain controller and aWAN link fail simultaneously What should you recommend?()A、In each site, install two global catalog servers.B、In each site, install two domain controllers. Enable Universal Group Membership caching for each site.C、In each site, install two domain controllers. Create a publishing point for an offline address list on one Exchange server in each site.D、In each site, install one domain controller that is configured as a global catalog server.Enable Universal Group Membership caching for each site.
考题
Your company has a main office and 10 branch offices. Each office has a direct link to the Internet. Each branch office has a WAN link that connects to the main office. Your network consists of an Active Directory forest. Each office is configured as an Active Directory site. You plan to deploy an Exchange Server 2010 Hub Transport server in each site. You need to design a message routing solution to meet the following requirements: .Branch office connections to the Internet must be used to deliver e-mail .Branch office servers must use the WAN link to the main office to deliver e-mail to other branch offices.Branch office servers must be prevented from sending e-mail to the Internet by using the WAN link to themain office .The solution must minimize administrative overhead What should you include in the solution?()A、one Send connector for each siteB、one SMTP site link for each siteC、two Send connectors for each siteD、10 Send connectors for each site
考题
You have a main office and five branch offices. The offices connect to each other by using a WAN link. An Active Directory site exists for each office. Each site has a separate IP site link to all other sites. The main office site is configured as a hub site. You have an Exchange Server 2010 organization. You discover that messages sent between offices are not routed through the Hub Transport servers in themain office. You need to ensure that all messages sent between offices are routed through the Hub Transport serversin the main office. What should you do?()A、Change all IP site links to SMTP site links.B、Modify the Exchange-specific cost for each site link.C、From the Hub Transport servers in each site, create a journal rule.D、From the Hub Transport servers in each site, create a transport rule.
考题
单选题You are deploying two core switches, one in each building, 50 km away from each other. The cross-connection between them will be a Layer 2 2-gigabit EtherChannel with an 802.1Q trunk. You configured it correctly but the link does not come up. The port is in the "admin up" state, and the line protocol is in the "down" state. The fiber link is OK. What would be the most likely reason for the link not to come up? ()A
The switches are not the same modelB
You are not using the correct SFPC
You are not using correct optical media convertersD
Configuration should be modified, because the distance is longer
考题
单选题You have just created a new VLAN on your network. What is one step that you should include in your VLAN-based implementation and verification plan? ()A
Verify that trunked links are configured to allow the VLAN traffic.B
Verify that the switch is configured to allow for trunking on the switch ports.C
Verify that each switch port has the correct IP address space assigned to it for the new VLAN.D
Verify that different native VLANs exist between two switches for security purposes.
考题
单选题You have just created a new VLAN on your network. What is one step that you should include in your VLAN based implementation and verification plan? ()A
Verify that different native VLANs exist between two switches for security purposes.B
Verify that the VLAN was added on all switches with the use of the show vlan command. C
Verify that the switch is configured to allow for trunking on the switch ports.D
Verify that each switch port has the correct IP address space assigned to it for the new VLAN.
考题
单选题You enabled CDP on two Cisco Routers which are connected to each other. The Line and Protocol statusfor the interfaces on both routers show as UP but the routers do not see each other a CDP neighbors.Which layer of the OSI model does the problem most likely exist?()A
PhysicalB
SessionC
ApplicationD
Data-LinkE
Network
考题
单选题You are configuring an 802.1Q trunk between a Layer 2 switch and a firewall. You read in the documentation that the best way to set up a trunk is to set the port as dynamic desirable. The trunk is not coming up. Which one of these options would be a valid explanation? ()A
The firewall does not support Cisco Discovery Protocol. You should set the switchport trunk mode ONB
The firewall does not support Cisco Discovery Protocol. You should set the switchport trunk mode to OFFC
The firewall does not support Cisco Discovery Protocol. You should set the switchport trunk mode asauto.D
The firewall does not support DTP. You should set the switchport trunk mode to ON
考题
单选题You have just created a new VLAN on your network for inter-VLAN routing. What is one step that you should include in your VLAN-based implementation and verification plan?()A
Verify that different native VLANs exist between two switches for security purposes.B
Verify that the switch is configured to allow for trunking on the switch ports.C
Verify that each switch port has the proper IP address space assigned to it for the new VLAN. D
Verify that the VLAN virtual interface has been correctly created and enabled.
考题
单选题To which switch or switches should you provide redundant links in order to achieve high availability with reliable fast convergence in the enterprise campus?()A
to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 2 linkB
to a core switch running Cisco NSF and SSO from redundant distribution switches connected with a Layer 3 linkC
to two core switches from redundant distribution switches connected with a Layer 2 linkD
to two core switches from redundant distribution switches connected with a Layer 3 linkE
to two core switches running Cisco NSF and SSO from two redundant distribution switches running Cisco NSF and SSO
考题
单选题The Company core switches use 802.1Q trunks to connect to each other. How does 802.1Q trunking keep track of multiple VLANs? ()A
It tags the data frame with VLAN information and recalculates the CRC valueB
It encapsulates the data frame with a new header and frame check sequenceC
It modifies the port index of a data frame to indicate the VLAND
It adds a new header containing the VLAN ID to the data frameE
None of the other alternatives apply
考题
单选题Your company has 10 offices. The offices connect to the Internet by using a WAN link. The offices connect to each other by using a VPN connection. An Active Directory site exists for each office. You plan to deploy Exchange Server 2010. Each site will contain two Exchange Server 2010 servers. You need to recommend the placement of domain controllers and global catalog servers to meet thefollowing requirements: .Minimize the number of domain controllers .Must be able to deliver e-mail messages between users of the same office, if a domain controller and aWAN link fail simultaneously What should you recommend?()A
In each site, install two global catalog servers.B
In each site, install two domain controllers. Enable Universal Group Membership caching for each site.C
In each site, install two domain controllers. Create a publishing point for an offline address list on one Exchange server in each site.D
In each site, install one domain controller that is configured as a global catalog server.Enable Universal Group Membership caching for each site.
考题
单选题You need to connect two Company core switches via an ISL trunk. Which statement is true regarding the configuration of ISL trunks? ()A
A Catalyst switch cannot have ISL and IEEE 802.1q trunks enabled.B
All Catalyst switches support ISL trunking.C
A Catalyst switch will report giants if one side is configured for ISL while the other side is not.D
ISL trunking requires that native VLANs match.E
None of the other alternatives apply
考题
单选题Which of the following is true concerning best design practices at the switched Access layer of thetraditional layer2 Enterprise Campus Network?()A
Cisco NSF with SSO and redundant supervisors has the most impact on the campus in theAccess layerB
Provides host-level redundancy by connecting each end device to 2 separate Access switches C
Offer default gateway redundancy by using dual connections from Access switches toredundant Distribution layer switches using a FHRPD
Include a link between two Access switches to support summarization of routing information
考题
多选题You have a trunk link operating between two switches and you’re experiencing problems withframes leaking between the two VLANs. Each switch has identical modules, software revisionsand VLAN configuration information. Spanning tree protocol is disabled on all VLANs. What isprobably causing this problem?()AThe link is using IEEE 802.1Q protocolBThe link is using IEEE 802.1E protocolCSpanning tree is disabledDNot enough information to determineEThe native VLAN information is identical at each end of the linkFThe native VLAN information is different at each end of the link