网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
A diesel driven emergency generator is prevented from being paralleled with the ships service generators by ()
A
an electrical interlock system
B
an automatic paralleling trip switch
C
the synchronizing oscilloscope
D
the reverse current relay
参考答案
参考解析
解析:
暂无解析
更多 “单选题A diesel driven emergency generator is prevented from being paralleled with the ships service generators by ()A an electrical interlock systemB an automatic paralleling trip switchC the synchronizing oscilloscopeD the reverse current relay” 相关考题
考题
For most diesel propulsion and generator engines, the over-speed trip device will stop the engine byA.moving the governor control to stopB.shutting off the lubricating oil supplyC.tripping the governor emergency stop leverD.shutting off the fuel supply
考题
When the ships is going to enter into the harborA.change from heavy fuel oil to diesel oil for main engineB.pumping out bilge waterC.change sea chest form high level one to lower level oneD.test emergency generator
考题
When the ship is going to enter into the harbor, ____.A.change from heavy fuel oil to diesel oil for main engineB.pumping out bilge waterC.change sea chest from high level one to lower level oneD.test emergency generator
考题
The emergency generator or emergency battery is connected to _______on most large ships.A.distribution boardsB.section boardsC.emergency switch boardsD.main switch boards
考题
It ______ for an emergency generator to require paralleling.A.is not usualB.is usualC.is necessaryD.is not impossible
考题
A generator is prevented from becoming motorized by the use of a/an ______.A.over-speed tripB.reverse power relayC.back pressure tripD.governor controls
考题
单选题When the ship is going to enter into the harbor,()A
change from heavy fuel oil to diesel oil for mail engineB
pumping oil bilge waterC
change sea chest form high level one to lower oneD
test emergency generator
考题
单选题When can routine communications be resumed on a frequency or channel on which radio silence has been imposed? ()A
After determining that the frequency or channel appears to be no longer in useB
After determining that geographic distance from the distress situation will prohibit any other signal from interfering with emergency communicationsC
After the Rescue Coordination Center transmits a message on the frequency or channel being used for emergency communications stating that such traffic has concludedD
Routine communications can resume if,in the Master's opinion,communications on that frequency or channel will not interfere with emergency communications
考题
单选题When can routine communications be resumed when radio silence has been imposed?()A
After determining that the frequency or channel appears to be no longer in useB
After determining that geographic distance from the distress situation will prohibit any other signal from interfering with emergency communicationsC
Routine communications can resume after the Rescue Coordination Center transmits a message on the frequency or channel being used for emergency communications stating that such traffic has concludedD
If,in the Master's opinion,communications on that frequency will interfere with emergency communications
考题
单选题For most diesel propulsion and generator engines, the over-speed trip device will stop the engine by ()A
moving the governor control to stopB
shutting off the lubricating oil supplyC
tripping the governor emergency stop leverD
shutting off the fuel supply
考题
单选题You have two listener processes, named L1 and L2. Both the listener processes are currently functional. While viewing the listener.ora file on your database server, you find the following entry: PASSWORDS_L1 = (1sanfrjp43) What would be the impact of this setting?()A
The listener process named L1 will disconnect the unauthorized users.B
The listener process named L1 will be prevented from being started by unauthorized users. C
The listener process named L1 will be prevented from being stopped by unauthorized users. D
The listener process named L1 will be prevented from being reloaded by unauthorized users.E
The listener process named L1 will be prevented from accepting connections from unauthorized users.
考题
单选题An emergency diesel generator should automatically shut down in the event of ()A
dangerous over-speedingB
a loss of lube oil pressureC
activation of the fixed CO2 system for the emergency generator spaceD
all of the above
考题
单选题Cooling water pumps driven by direct reversing diesel engines are usually of the straight impeller vane type pump with a concentric housing to()A
facilitate bi-directional operationB
provide the greatest pump efficiencyC
prevent pump clogging from marine growthD
prevent cavitation at the pump outlet
考题
单选题The load limitation of governor should be reduced when ship navigating at sea, the main reason is to()A
prevent the diesel engine surgingB
prevent governor from being damaged because of swingC
reduce the probability of the crank shaft being torsional vibrated and resonatedD
prevent the main engine being overload or overspeed
考题
单选题An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every ()A
weekB
2 weeksC
monthD
3 months
考题
单选题()of the following need not be entered in the official logbook?A
The testing of the internal combustion engine driven emergency generator at least once each month the vessel is navigatedB
The testing of storage betteries for emergency lighting and systems once each 6 months the vessels is navigatedC
The actual draft when the vessel arrives in salt water after department a portD
The testing of the line-throwing appliance once every 3 months
考题
单选题The booster pump, which supplies diesel oil to() , should have a possibility of being powered by compressed air or by emergency power.A
the main enginesB
the auxiliary enginesC
the emergency generator engineD
the auxiliary engines and the main engine(s)
考题
单选题Combustion gases formed in the cylinder of a diesel engine are prevented from blowing past the piston by ()A
cylinder valvesB
compression ringsC
piston skirtsD
oil rings
考题
单选题A diesel generator has just been paralleled with an AC turbo-generator, but the load can not be properly divided.This could be caused by()A
an incorrect diesel generator governor speed droop adjustmentB
a faulty reverse power relay within the main circuit breaker assemblyC
unsynchronized isochronous load distribution adjustmentsD
a different speed setting on each unit
考题
单选题Standby or emergency diesel generator day tanks should always be kept full to reduce the possibility of()A
sediment contaminationB
fuel filter cloggingC
moisture formationD
inadequate transfer pump suction head
考题
单选题The emergency generator or emergency battery is connected to() on most large ships.A
distribution boardsB
section boardsC
emergency switch boardsD
main switch boards
考题
单选题A generator is prevented from becoming motorized by the use of a/an ().A
over-speed tripB
reverse power relayC
back pressure tripD
governor controls
考题
单选题It () for an emergency generator to require paralleling.A
is usualB
is not usualC
is necessaryD
is not impossible
考题
单选题When the ships is going to enter into the harbor,().A
change from diesel oil to heavy fuel oil for mail engineB
pump out bilge waterC
change sea chest form lower level one to high level oneD
test emergency generator
考题
单选题On a ship,each emergency generator must be tested at least once each().A
weekB
monthC
three monthsD
six months