单选题
A fire must be ventilated().
A
when using an indirect attack on the fire such as flooding with water
B
to prevent the gases of combustion from surrounding the firefighters
C
to minimize heat buildup in adjacent compartments
D
if compressed gas cylinders are stowed in the compartment on fire
参考答案
参考解析
解析:
暂无解析
更多 “单选题A fire must be ventilated().A when using an indirect attack on the fire such as flooding with waterB to prevent the gases of combustion from surrounding the firefightersC to minimize heat buildup in adjacent compartmentsD if compressed gas cylinders are stowed in the compartment on fire” 相关考题
考题
At the earliest indication of fire aboard your vessel, you must FIRST ______.A.locate the fireB.determine which type of fire is burningC.sound the alarmD.fight the fire
考题
The ventilation system of your ship has fire dampers restrained by fusible links. Which statement is TRUE?A.Fusible links must be replaced if a damper is activatedB.Fusible links are tested by applying a source of heat to themC.Fusible links must be replaced at every inspection for certificationD.A fusible link will automatically open after a fire is extinguished and reset the damper
考题
All oil spills must be reported to the ______.A.MOCB.MSA OF CHINAC.local policeD.local fire department
考题
Oceangoing dry bulk cargo vessels over 1000 GT must have approved combination-type fire nozzles at all ______.A.Fire stations aboard the vessel,except for those in open deck areas weatherdeck and cargo hold fire stationsB.Interior fire stationsC.Engine room fire stationsD.All of the above
考题
A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the ______.A.Fire hose might be damaged by cargo operationsB.Vessel is in portC.Fire-main system is not chargedD.Fire pumps are used for purposes other than supplying water to the fire main
考题
A cabinet or space containing the controls or valves for the fixed firefighting system must beA.posted with instructions on the operation of the systemB.ventilated and equipped with explosion-proof switchesC.painted with red and black diagonal stripesD.equipped with a battery powered source of emergency lighting
考题
All portable fire extinguishers must be capable of being ______.A.carried by hand to a fireB.carried or rolled to a fireC.recharged in the fieldD.used on class “B” fire
考题
Fire axes required on MV MODU’s must be stored in the enclosure for fire hoses with the location marked ______.A.Fire Axe LocationB.Hose Station No. …C.Fire Station No. …D.Firefighting Equipment
考题
There is a smell of gas in the hold. You must wear your ()(氧气面罩).A、fire maskB、breathing apparatusC、life-jacketD、fire drill
考题
Wires that are installed in air returns above a ceiling must be()A、fire proofB、fiberglass coatedC、plenum ratedD、teflon coated
考题
单选题The ventilation system of your ship has fire dampers restrained by fusible links. Which statement is TRUE?()A
A fusible link will automatically open after a fire is extinguished and reset the damperB
Fusible links must be replaced at every inspection for certificationC
Fusible links are tested by applying a source of heat to themD
Fusible links must be replaced if a damper is activated
考题
单选题In the event of a fire, the doors to a stair tower must be closed to prevent the spread of fire by ().A
convectionB
conductionC
radiationD
ventilation
考题
单选题If a scavenge fire starts, the engine must be put to “()” and the fuel must be taken off the cylinders affected by the fire.A
stop engineB
finished with engineC
dead slow aheadD
dead slow astern
考题
单选题Oceangoing dry bulk cargo vessels over 1000 GT must have approved combination-type fire nozzles at all().A
fire stations aboard the vessel,except for those in open deck areas weatherdeck and cargo hold fire stationsB
interior fire stationsC
engine room fire stationsD
all of the above
考题
单选题When should a fire be ventilated?()A
When attacking the fire directlyB
When using a steam smothering systemC
When using the fixed CO2 systemD
All of the above
考题
单选题If you must enter a room or compartment to combat the fire, keep an escape path ().A
openB
closeC
opensD
closes
考题
单选题All oil spills must be reported to the().A
MOCB
MSA OF CHINAC
local policeD
local fire department
考题
单选题The four basic components of a fire are fuel, heat, oxygen and a chain reactionWhich of the following statements best describes what must be eliminated to extinguish a fire?()A
Any one component can be eliminated to extinguish a fireB
Any two components must be eliminated to properly extinguish a fireC
Any three components must be eliminated to properly extinguish a fireD
Ali four components must be eliminated to extinguish any fire
考题
单选题Which condition is necessary for a substance to burn?()A
The temperature of the substance must be equal to or above its fire pointB
The air must contain oxygen in sufficient quantityC
The mixture of vapors with air must be within the explosive rangeD
All of the above
考题
单选题The air reservoirs must have () fitted to prevent rupture in the event of fire.A
high pressure alarmB
fire alarmC
extinguishersD
fusible plugs
考题
单选题At the earliest indication of fire aboard your vessel, you must FIRST().A
locate the fireB
determine which type of fire is burningC
sound the alarmD
fight the fire
考题
单选题Each fire hose coupling on a ship must have threads that meet the specifications of the().A
American Petroleum InstituteB
National Standard Fire hose CouplingC
American Society of Mechanical EngineersD
Underwriter's Laboratories,Inc
考题
单选题All portable fire extinguishers must be capable of being().A
carried by hand to a fireB
carried or rolled to a fireC
recharged in the fieldD
used on class 'B' fires
考题
单选题Each fire pump on a ship must have a pressure gauge located at().A
the pump dischargeB
the manifold connectionC
each fire station dischargeD
the pump station
考题
单选题______ fire, all exits must be kept clear.A
In place ofB
Instead ofC
In case ofD
In spite of
考题
单选题The lubrication to the cylinders affected by the fire must be ()to prevent seizure and all scavenge drains must be ()to prevent the discharge of sparks and burning oil from the drains into the engine room.A
decreased;openedB
decreased;shutC
increased;openedD
increased;shut
考题
单选题If not attached to the nozzle,each low-velocity spray applicator on a vessel must be stowed().A
in a protected area on the main deckB
inside a machinery space near the entranceC
next to the fire hydrant to which the fire hose is attachedD
on a rack inside the quarters near the entrance