单选题
A thermostatic expansion valve is properly controlling evaporator superheatAdjusting this valve to lower the superheat will result in a/an ().
A

evaporator pressure decrease

B

evaporator coil over-feed

C

evaporator capacity increase

D

expansion valve diaphragm rupture


参考答案

参考解析
解析: 暂无解析
更多 “单选题A thermostatic expansion valve is properly controlling evaporator superheatAdjusting this valve to lower the superheat will result in a/an ().A evaporator pressure decreaseB evaporator coil over-feedC evaporator capacity increaseD expansion valve diaphragm rupture” 相关考题
考题 When replacing a thermostatic expansion valve sensing bulb, it is necessary toA.apply a light film of oil to increase heat transferB.apply a light film of oil to prevent oxidationC.apply a heavy coating of grease to function as a heat sinkD.carefully coat the device with silicone sealant to reduce the effects of convective cooling

考题 A thermostatic expansion valve is properly controlling evaporator superheat. Adjusting this valve to lower the superheat will result in a/anA.evaporator pressure decreaseB.evaporator coil over-feedC.evaporator capacity increaseD.expansion valve diaphragm rupture

考题 单选题During working, thermostatic expansion valve should be ().A either all the way open or all the way closedB normally fully openC throttled depending on loadD controlled by liquefied pressure

考题 单选题The thermal expansion valve controls the amount of refrigerant that is allowed to flow to the ().A compressorB cooling coilsC condenserD receiver

考题 单选题If a refrigeration system compressor crankcase is sweating, you should ().A add refrigerant to the systemB adjust the thermal expansion valve to the proper settingC adjust the float valve to the proper holding pressureD open the hand expansion valve

考题 单选题Which one of following statement is not true concerning the suitable sites of the direct acting relief valve and the pilot operated relieve valve?()A the direct acting relief valve is used for controlling lower flows and pressureB the pilot operated relief valve is used for controlling higher flows and pressureC the pilot operated relief valve is used for controlling lower flows and pressureD the controlling accuracy of direct acting relief valve is worse than that of the pilot operated relief valve

考题 单选题A three-way thermostatic control valve regulates the diesel engine cooling water temperature by passing a portion of the water ().A around the engineB around the coolerC to the expansion tankD overboard

考题 单选题If the operating element of a thermostatic valve installed in a diesel engine cooling system malfunctions, it may result in ()A a low level in the engine expansion tankB excessively high coolant pressureC improper temperaturesD malfunctioning of the jacket water heater

考题 单选题A ruptured diaphragm in a thermostatic expansion valve will cause the valve to ().A openB closeC remain in its positionD flood the evaporator with refrigerant

考题 单选题The scale trap is located between the ()A king valve and the expansion valveB solenoid valve and expansion valveC evaporator and receiverD compressor and evaporator

考题 单选题What is the function of thermostatic expansion valve in a compression refrigeration system?()A nonexistentB for controlling pressureC for controlling superheatD for controlling the solenoid valve

考题 单选题Thermostatic expansion valve are ().A either all the way open or all the way closedB normally openC throttled depending on loadD controlled by suction pressure

考题 单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()A The liquid receiver functions to collect and remove non-condensable gasesB A thermostatic expansion valve is used to control refrigerated space temperatureC Refrigerant temperature in an evaporator is directly related to refrigerant pressureD Dehydrators must be used continuously in a refrigeration system

考题 单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A Condenser and thermal expansion valveB King and solenoid valvesC Compressor and thermal expansion valveD Condenser and solenoid valve

考题 单选题Which of the following would not cause high suction pressure?()A insufficient refrigerationB leaky suction valvesC expansion valve stuck openD suction valve not adjusted properly

考题 单选题When the heat load begins to increase, the needle valve of an expansion valve will()A move in an opening directionB move in a closing directionC either open or closeD not move at all

考题 单选题A solenoid valve used in a refrigeration system should be installed ().A with the axis of the solenoid horizontal, sensing temperature of the box, and upstream of the thermal expansion valveB upright, sensing temperature of the box, and upstream of the thermal expansion valveC upright, sensing temperature of the box, and downstream of the thermal expansion valveD upright, sensing heat of the tail coil, and upstream of the thermal expansion valve

考题 单选题A cracked diaphragm in a thermostatic expansion valve will cause the valve to ().A return to a neutral positionB flood the evaporatorC openD close

考题 单选题Which of the listed statements is correct concerning refrigeration systems?()A Dehydrators must be used continuously in a refrigeration systemB A 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hoursC A thermostatic expansion valve is used to control refrigerated space temperatureD The liquid receiver functions to collect and remove non- condensable gases

考题 单选题The thermostatic valve has a throttling action, that is to say the valve can()A stop the refrigerant from flowingB force the refrigerant to flowC cause the refrigerant pressure to riseD cause the refrigerant pressure to fall

考题 单选题Which of the listed statements is a characteristic of the liquid charged power element used with thermostatic expansion valves?()A At the designed operating temperature, the liquid refrigerant charge has changed to a vaporB The liquid refrigerant tends to collect at the bellows or diaphragm and reduces the valve sensitivityC The sensing bulb is empty of liquid refrigerant charge at the designed operating temperatureD The sensing bulb is never emptied of liquid refrigerant under normal operating conditions

考题 单选题When the refrigeration demand is small,()A the expansion valve will move toward the wide open positionB the expansion valve will move toward the closing positionC the feeler bulb will conveys the high temperatureD the superheat degree will raise

考题 单选题Thermostatic expansion valves can be adjusted for ().A suction pressure onlyB head pressure onlyC superheat onlyD suction pressure and box temperature

考题 单选题To correct the condition of slugging and flooding back in a refrigeration system, it may be necessary to ().A re-adjust the discharge pressureB clean the expansion valve screenC add refrigerantD adjust the expansion valve

考题 单选题The low pressure side of a refrigeration system is considered to exist from the ().A expansion valve to the compressorB receiver to the expansion coilC expansion valve to the evaporatorD condenser to the expansion valve

考题 单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A The condenser and the expansion valveB The king valve and the solenoid valveC The compressor and the expansion valveD The condenser and the solenoid valve

考题 单选题The jacket water temperature in a diesel engine closed freshwater cooling system is normally controlled by ()A regulating the level of corrosion inhibitor in the primary cooling systemB the level of the freshwater expansion tankC varying the engine load to meet temperature requirementsD the operation of the thermostatic valve