网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()
- A、 Cisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXes
- B、 Cisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXes
- C、 Two Cisco UCS 6100 Series or 6200 Series fabric interconnects
- D、 Two RJ45 Ethernet cables
- E、 The fabric interconnects must be in end-host mode
参考答案
更多 “What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()A、 Cisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesB、 Cisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesC、 Two Cisco UCS 6100 Series or 6200 Series fabric interconnectsD、 Two RJ45 Ethernet cablesE、 The fabric interconnects must be in end-host mode” 相关考题
考题
What is the appliance port used to connect to in a Cisco Unified Computing System?()A、 Fibre Channel storageB、 UCS C-Series serversC、 NFS storageD、 UCS chassisE、 Other fabric interconnect
考题
Which two Cisco UCS features facilitate easy deployment of server farms?()A、cloningB、CMCsC、IOMsD、Templates
考题
Which two steps are the result of associating a blade server?()A、The compute node reboots and is then connected to the CMCB、A compute node is assigned to a service profileC、if the association is successful the cisco UCS manager boots the cisco UUOS to configure the compute nodeD、The compute node reboots to reload and then loads NX OS and establishes connections to both the CMC and the IOMs
考题
Which component of the Cisco Nexus 1000v m0nitors the migration of a Vinual machine during Vmotionevents?()A、UCS ManagerB、Viltual Supervisor ModuleC、ViItuaI Ethernet ModuleD、Distributed Viltual Switch
考题
From the Cisco UCS CLI, how do you verify which uplink ports a blade server is using for its network connectivity?()A、 UCS-A# show pinning border-interfacesB、 UCS-B# show service-profile circuitC、 UCS-B(nxos)# show pinning server-interfacesD、 You must statically configure which uplink the blades should use, or you will not have connectivity.
考题
Cisco UCS Manager provides the ability to manage power utilization to the blades. Which two statements about UCS Manager power policies are true? ()A、 Power capping helps mainly in reducing data center footprint.B、 Power capping helps reduce data center cooling.C、 A single power cap group policy allows you to set power limits across multiple UCS domains. D、 You can have multiple power cap groups per UCS domain.E、 Each blade within a UCS 5108 chassis can belong to a separate power cap group.
考题
Which statement ab0ut VLANs in a Cisco UCS is true?()A、Fabric interconnect can never participate in VTPB、Fabric interconnect supports ISL and 802.1Q trunkingC、The supported range of VLANs is auto-configured by UCSD、VLANs are configured through the Cisco UCS manager. (fabric interconnect may be set up in switch mode)
考题
Due to the internal Fiber Channel over Ethernet architecture of the Cisco UCS ,what does each VSANrequire?()A、it is carried on only 1 vhba per ucs systemB、it has a qos policy in order to maintain traffic priorityC、there is a supporting vsan to carry the fcoe trafficD、there is a dedicated VLAN to carry the FCoEtraffic
考题
Which three Server Pool Qualifications are used in the Cisco UCS manager?()A、firmwareB、CPUC、memoryD、adapter card
考题
Which three roles are predefined in the Cisco UCS system?()A、Server AdminB、Network AdminC、Storage AdminD、Security Admin
考题
Where are Cisco UCS vNICs created?() A、 In the blade BIOSB、 In the operating systemC、 In the service profileD、 In the card option ROM
考题
Which component of the Cisco nexus 1000v monitors the migration of virtual machine during vmotion events?()A、UCS MangerB、virtual supervisor moduleC、virtual ethernet moduleD、distributed virtual switch
考题
Which three objects represent pools used in Mobile Service Profiles in the Cisco UCS?()A、WWNB、VSANC、UUIDD、MACE、VU/N
考题
Cisco UCS provides integration interfaces and protocols to support heterogeneous data center environments and supports standard monitoring and event notification systems, providing data to standard enterprise-management tools. Which two of these list the primary Cisco UCS interfaces and industry standard-based read-only interfaces? ()A、 UCS Manager XML API and UCS CLIB、 SNMP, SMASH CLP, and CIM-XMLC、 UCS Manager, DCOS, and Local-mgmtD、 SoL and NX-OSE、 debug-plugin and UCS Manager GUI
考题
Which Cisco product is a storage comp0nent of the Cisco data center Unified Computing Solution?()A、Nexus 1000B、UCS5 5100C、Catalyst 6500D、MDS 9000
考题
Which two statements regarding SNMP monitoring of a UCS system are correct?()A、SNMP v3 is supportedB、includes same MIBs as the Cisco Nexus7000C、does not provides MIBs downstream of the fabric interconnectD、includes same MIBs as the Cisco Nexus2000
考题
When will an "all configuration" backup be imported into the Cisco UCS Manager?()A、 During the initial configuration from the consoleB、 Once the basic configuration has been appliedC、 To restore the configuration on a secondary fabric interconnectD、 To upgrade the firmware on a replacement fabric interconnect
考题
单选题When will an "all configuration" backup be imported into the Cisco UCS Manager?()A
During the initial configuration from the consoleB
Once the basic configuration has been appliedC
To restore the configuration on a secondary fabric interconnectD
To upgrade the firmware on a replacement fabric interconnect
考题
多选题Which two steps are the result of associating a blade server?()AThe compute node reboots and is then connected to the CMCBA compute node is assigned to a service profileCif the association is successful the cisco UCS manager boots the cisco UUOS to configure the compute nodeDThe compute node reboots to reload and then loads NX OS and establishes connections to both the CMC and the IOMs
考题
多选题Which three objects represent pools used in Mobile Service Profiles in the Cisco UCS?()AWWNBVSANCUUIDDMACEVU/N
考题
多选题Which three roles are predefined in the Cisco UCS system?()AServer AdminBNetwork AdminCStorage AdminDSecurity Admin
考题
单选题Due to the internal Fiber Channel over Ethernet architecture of the Cisco UCS ,what does each VSANrequire?()A
it is carried on only 1 vhba per ucs systemB
it has a qos policy in order to maintain traffic priorityC
there is a supporting vsan to carry the fcoe trafficD
there is a dedicated VLAN to carry the FCoEtraffic
考题
单选题What is the appliance port used to connect to in a Cisco Unified Computing System?()A
Fibre Channel storageB
UCS C-Series serversC
NFS storageD
UCS chassisE
Other fabric interconnect
考题
多选题Cisco UCS provides integration interfaces and protocols to support heterogeneous data center environments and supports standard monitoring and event notification systems, providing data to standard enterprise-management tools. Which two of these list the primary Cisco UCS interfaces and industry standard-based read-only interfaces? ()AUCS Manager XML API and UCS CLIBSNMP, SMASH CLP, and CIM-XMLCUCS Manager, DCOS, and Local-mgmtDSoL and NX-OSEdebug-plugin and UCS Manager GUI
考题
多选题What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()ACisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesBCisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesCTwo Cisco UCS 6100 Series or 6200 Series fabric interconnectsDTwo RJ45 Ethernet cablesEThe fabric interconnects must be in end-host mode
考题
单选题Which statement ab0ut VLANs in a Cisco UCS is true?()A
Fabric interconnect can never participate in VTPB
Fabric interconnect supports ISL and 802.1Q trunkingC
The supported range of VLANs is auto-configured by UCSD
VLANs are configured through the Cisco UCS manager. (fabric interconnect may be set up in switch mode)
考题
单选题From the Cisco UCS CLI, how do you verify which uplink ports a blade server is using for its network connectivity?()A
UCS-A# show pinning border-interfacesB
UCS-B# show service-profile circuitC
UCS-B(nxos)# show pinning server-interfacesD
You must statically configure which uplink the blades should use, or you will not have connectivity.