网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
If the electric motor driving an air compressor fails to start, the cause may be a ().
A
leaking unloader
B
tripped circuit breaker
C
control line leak
D
defective pop valve
参考答案
参考解析
解析:
暂无解析
更多 “单选题If the electric motor driving an air compressor fails to start, the cause may be a ().A leaking unloaderB tripped circuit breakerC control line leakD defective pop valve” 相关考题
考题
In an AC.synchronous motor electric propulsion plant,propeller speed is controlled by()
A.prime mover speedB.number of energized main motor polesC.propulsion generator field strengthD.electric coupling field strength
考题
单选题Air blowing from the intake air filter of an operating air compressor indicates ().A
broken inlet valvesB
broken discharge valvesC
pulsations in the air distribution systemD
overloading of the air distribution system
考题
单选题If an electric motor driven air compressor fails to start, it may be due to a ().A
leaking discharge valveB
jammed suction valveC
tripped overload relayD
broken discharge un-loader
考题
单选题On opposite ends of a single shaft of a turboblower are a gas driven ()and a air compressor, which are sealed each other.A
charge air receiverB
scavenging air beltC
turbineD
air cooler
考题
单选题The unloading system on an air compressor will ().A
increase compressor discharge pressure on demandB
increase compressor operating speed as necessaryC
allow the motor to turn the compressor opposed only by frictionD
reduce the compressor frictional load when starting
考题
单选题操作完后,关掉电动机。()A
After operation, start the electric motor.B
Before operation, stop the electric motor.C
Before operation, start the electric motor.D
After operation, stop the electric motor.
考题
单选题()are supplied by main switchboard directly.A
Suez Canal searchlight, air compressor and air conditioning compressorB
Air compressor, boiler blower and refrigeration plantC
Boiler blower, Suez Canal searchlight and refrigeration plantD
Suez canal searchlight, air compressor and boiler blower
考题
单选题Broken valve strips in an operating low pressure, air compressor will cause ().A
an immediate crankcase explosionB
oil contamination in the compressed airC
a decrease in compressor capacityD
no immediate loss of the compressed air capacity
考题
单选题If the electric motor driving an air compressor fails to start, the cause may be a ().A
leaking unloaderB
tripped circuit breakerC
control line leakD
defective pop valve
考题
单选题Any electric motor can be constructed to be().A
short proofB
ground proofC
explosion proofD
overload proof
考题
单选题“A centrifuge consists of an electric motor driving a vertical shaft on the top of which is mounted the bowl assembly”.According to this sentence, we can know that is mounted on the top of the vertical shaft()A
a centrifugeB
an electric motorC
a bowl assemblyD
a driving motor
考题
单选题When there is a fire in a large electric motor, normally the very FIRST step is to ()A
secure the electric supplyB
ventilate area to remove smokeC
start the fire pump and lead out hoseD
apply foam
考题
单选题The air compressor pumps air to the ().A
expansion tankB
combustion chamberC
air receiverD
evaporator
考题
单选题The purpose of an air compressor unloading device is to ()A
drain water from the air receiverB
drain water from the cylindersC
delay the compression process until the motor is up to speedD
check pump alignment
考题
单选题The air compressor pumps air to the ().A
air cylinderB
combustion chamberC
steam drumD
expansion tank
考题
单选题The air compressor pumps air to the().A
engine cylinderB
air bottleC
evaporatorD
condenser
考题
单选题The air filter is fixed in the () of an air compressor.A
inlet pipeB
outlet pipeC
inter coolerD
after cooler
考题
单选题After operation, drop the control levers into stowing hole, and ()the electric motor.A
startB
stopC
moveD
open
考题
单选题If an air compressor is used to supply compressed air to outlets throughout the engine room and on deck of a vessel, the system is known as the ().A
combustion control air systemB
supply air systemC
ships service air systemD
low pressure deck air system
考题
单选题An un-loader is installed on an air compressor to ().A
bypass the high pressure stage to the low pressure stage on 100% of the air compressors in serviceB
prevent excessive inter-stage pressure buildupC
control compressor discharge pressureD
remove all but the frictional load during starting
考题
单选题Starting air for auxiliary engines may be taken directly from the main reservoirs or through ().A
an auxiliary reservoirB
a controlling air bottleC
an emergency air compressorD
a main air compressor
考题
单选题Air compressor cylinder un-loaders enable the compressor to ().A
vary their speed according to temperature and loadB
start and come up to speed before air compression beginsC
change speed according to overload demandsD
reduce compressed air charge density
考题
单选题After operation, drop the control levers into stowing hole, and ()(停止)the electric motor.A
startB
stopC
moveD
shift
考题
单选题What type of electric motor is most commonly used on board ship?()A
non-synchronous electric motorB
synchronous electric motorC
fully enclosed electric motorD
watertight electric motor
考题
单选题The air distributor is conventionally driven by() and distributes into each cylinder by() certain sequence.A
camshaft;fresh airB
camshaft;starting airC
electronic motor which is controlled by a computer;fresh airD
electronic motor which is controlled by a computer;starting air
考题
单选题If an air compressor is used to supply air primarily to the combustion control system and other pneumatic controllers, the entire system is known as the ().A
control air systemB
forced draft air systemC
supply air systemD
ships service air system
考题
单选题When a refrigeration compressor motor fails to start, the FIRST thing that should be checked for is a ().A
loose expansion valve control bulbB
low differential setting on the H-PcutoutC
blown fuse in the motor circuitD
faulty suction pressure regulator