网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)

Which of the following is MOST likely causing an intermittent flashing LED on an IR receiver when the remote control is not being used?()

  • A、The power supply is faulty and should be replaced.
  • B、The heat from a heating, ventilation, and air conditioning (HVAC) register is being received as infrared noise.
  • C、The radio frequency interference (RFI) is being received as noise.
  • D、A plasma display is emitting infrared noise.

参考答案

更多 “Which of the following is MOST likely causing an intermittent flashing LED on an IR receiver when the remote control is not being used?()A、The power supply is faulty and should be replaced.B、The heat from a heating, ventilation, and air conditioning (HVAC) register is being received as infrared noise.C、The radio frequency interference (RFI) is being received as noise.D、A plasma display is emitting infrared noise.” 相关考题
考题 Which of the processes listed would be the most satisfactory method to use to lower the humidity of the air being circulated by an air conditioning system?A.Cooling the air to a temperature just above dew pointB.Heating the air to a point at which moisture will boil off ,then re-cooling itC.Cooling the air to a point below dew point, then reheating itD.Heating the air and then cooling it to a point below dew point

考题 The main propulsion diesel engine jacket water temperature rises above normal, with the raw sea suction and the expansion tank water level being normal. Which of the following problems is most likely the cause?A.Faulty thermostatic bypass valveB.Eroded zinc pencils in the heat exchangerC.Steam formation in the expansion tankD.Excessive leakage from jacket water pump seals

考题 A user reports it takes a long time to load all applications and the hard drive LED is showing constant activity. Which of the following is MOST likely the issue?() A. The processor is faulty.B. The file system is fragmented.C. The modem drivers are corrupt.D. The power supply is faulty.

考题 A technician suspects the AC voltage into a PC power supply is bad. Which of the following toolswould MOST likely be used to confirm the diagnosis?() A. MultimeterB. OscilloscopeC. Cable testerD. Power supply tester

考题 A technician has had several support requests for one PC. The technician has reseated the PCIcards and replaced the hard drive in the PC located in a school cafeteria kitchen. PCs located in the business office or the classrooms have not had this issue.Which of the following is MOST likely causing this PC’s issue?()A. Faulty RAMB. 240 volt Kitchen outletsC. Power BrownoutsD. Excessive Heat

考题 Due to the large amount of heat picked up by the air in boiler and engine rooms, it would be impracticable to maintain ambient conditions within the comfort zone by air conditioning or any other means. The normal practice is to provide copious mechanical ventilation; in boiler rooms, the quantity is equated to the combustion requirements, while in a motor ship engine room the supply may be 25-50% in excess of the requirements of the engines.The axial flow fan is particularly suited to handle these large air volumes at the moderate pressures required, while of course the “straight-through” flow feature places it at an advantage over the centrifugal fan.The increasing adoption of automation, with the provision of a separate control room makes less significant the fact that comfort conditions cannot be maintained in the engine room all the time. Which of the following devices should be taken to maintain ambient conditions of the boiler and machinery space?A.air compressorB.air coolerC.air-conditioning plantD.mechanical ventilation plant

考题 Heating,ventilating,and air conditioning(HVAC) systems are______in most of underground subway stations to provide comfortable and fresh air to underground subway stations。A.assembled B.installing C.equipped D.installed

考题 If a technician suspects that the voltage being delivered to a desktop computer’s power supply is insufficient or incorrect, which device should be used to determine the correct voltage?()A、A power supply testerB、A multimeterC、A loopback adapterD、A cable tester

考题 Which of the following will help dissipate heat through the heat sink when upgrading a CPU? ()A、Case fanB、Thermal compoundC、Motherboard riserD、Power supply

考题 Which of the following tools is BEST used to measure voltage and amperage from a power source?()A、Loopback PlugB、MultimeterC、Power Supply TesterD、Extension Magnet

考题 A user is reporting that their computer is making strange noises and randomly powers off. Which of the following tools would MOST likely be used to troubleshoot this problem?()A、POST diagnostic cardB、Power supply testerC、Loop back plugD、Cable tester

考题 Which of the following is the MOST likely to cause a server power supply fan to fail but allows the power supply to still be functional?()A、DustB、Power SurgeC、Excessive humidityD、High temperatures

考题 A technician suspects the AC voltage into a PC power supply is bad. Which of the following toolswould MOST likely be used to confirm the diagnosis?()A、MultimeterB、OscilloscopeC、Cable testerD、Power supply tester

考题 A user reports it takes a long time to load all applications and the hard drive LED is showing constant activity. Which of the following is MOST likely the issue?()A、The processor is faulty.B、The file system is fragmented.C、The modem drivers are corrupt.D、The power supply is faulty.

考题 The user turns on the computer and hears a popping sound and detects a burning smell. Thesystem will not power on. Which of the following is the MOST likely problem?()A、Power supply has blown.B、CPU fan is faulty.C、Motherboard has overheated and shutdown.D、UPS has been tripped.

考题 A technician has had several support requests for one PC. The technician has reseated the PCIcards and replaced the hard drive in the PC located in a school cafeteria kitchen. PCs located in the business office or the classrooms have not had this issue. Which of the following is MOST likely causing this PC’s issue?()A、Faulty RAMB、240 volt Kitchen outletsC、Power BrownoutsD、Excessive Heat

考题 Which of the following is MOST useful in HVAC planning? ()A、 Uninterruptible Power Supply (UPS) loadB、 HumidityC、 AmperageD、 VoltageE、 Temperature

考题 Which of the following factors is the MOST likely cause of a power supply fan failure?()A、 Extreme temperature variancesB、 Extreme humidity variancesC、 Power stability fluctuationsD、 Excessive dust accumulation

考题 Which of the following should a technician MOST likely use to test a RS-232 port?()A、Loopback adapterB、Power supply testerC、The ping commandD、Multimeter

考题 单选题Which of the following factors is the MOST likely cause of a power supply fan failure?()A  Extreme temperature variancesB  Extreme humidity variancesC  Power stability fluctuationsD  Excessive dust accumulation

考题 单选题Which of the following is MOST likely causing an intermittent flashing LED on an IR receiver when the remote control is not being used?()A The power supply is faulty and should be replaced.B The heat from a heating, ventilation, and air conditioning (HVAC) register is being received as infrared noise.C The radio frequency interference (RFI) is being received as noise.D A plasma display is emitting infrared noise.

考题 单选题A user reports it takes a long time to load all applications and the hard drive LED is showing constant activity. Which of the following is MOST likely the issue?()A The processor is faulty.B The file system is fragmented.C The modem drivers are corrupt.D The power supply is faulty.

考题 多选题Which of the following is MOST useful in HVAC planning? ()AUninterruptible Power Supply (UPS) loadBHumidityCAmperageDVoltageETemperature

考题 单选题The user turns on the computer and hears a popping sound and detects a burning smell. Thesystem will not power on. Which of the following is the MOST likely problem?()A Power supply has blown.B CPU fan is faulty.C Motherboard has overheated and shutdown.D UPS has been tripped.

考题 单选题Which of the following methods is normally used to control the temperature of air distributed from individual cooling coils in an air conditioning system using a chilled water circulation system?()A A room thermostat activates an electric heater at each individual chilled air outlet when necessaryB Varying the number of passes the air makes across the coilsC Varying the temperature of the water through the coilsD Varying the quantity of water flowing through the coils

考题 单选题Which of the following is the MOST likely to cause a server power supply fan to fail but allows the power supply to still be functional?()A DustB Power SurgeC Excessive humidityD High temperatures

考题 单选题A technician suspects the AC voltage into a PC power supply is bad. Which of the following toolswould MOST likely be used to confirm the diagnosis?()A MultimeterB OscilloscopeC Cable testerD Power supply tester