网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
Where are SAN Port Channel is created in UCS Manager?()
A

 Under the Admin tab on the FI

B

 Under the Server tab in the service profile

C

 Under the SAN tab on each VSAN

D

 Under the Admin tab on the chassis

E

 Under the SAN tab on the Fabric Interconnect


参考答案

参考解析
解析: 暂无解析
更多 “单选题Where are SAN Port Channel is created in UCS Manager?()A  Under the Admin tab on the FIB  Under the Server tab in the service profileC  Under the SAN tab on each VSAND  Under the Admin tab on the chassisE  Under the SAN tab on the Fabric Interconnect” 相关考题
考题 WhatinterfaceiscreatedwhenanFCPortChanneliscreatedonaCiscoUnifiedComputingSystem?() A.Aninterface’san-port-channel’inNXOSB.Aninterface’port-channel’inNXOSC.Aninterface’port-channel’with’modefc’configuredD.Aninterface’fc-port-channel’inNXOS

考题 In a Cisco Unified Computing System, where are SAN port channels connected to?()A、 Only to Cisco Fibre Channel switchesB、 Only to Cisco Fibre Channel switches in NPIV modeC、 To any Fibre Channel switchD、 Directly to storage arraysE、 Only to Nexus Switches

考题 What is the use of NPV in Cisco Unified Computing Systems? ()    A、 Compatibility with third-party Fibre Channel switchesB、 Faster throughputC、 Reduce domain IDs in a Fibre Channel environmentD、 Support for increased number of VSANsE、 Support for SAN port channels

考题 What is the appliance port used to connect to in a Cisco Unified Computing System?()A、 Fibre Channel storageB、 UCS C-Series serversC、 NFS storageD、 UCS chassisE、 Other fabric interconnect

考题 Which protocol does the UCS Fabric Interconnect support on port channel uplinks?()A、LACPB、PAgPC、MCPC

考题 What interface is created when an FC Port Channel is created on a Cisco Unified Computing System?()A、 An interface ’san-port-channel’ in NXOSB、 An interface ’port-channel’ in NXOSC、 An interface ’port-channel’ with ’mode fc’ configuredD、 An interface ’fc-port-channel’ in NXOS

考题 Which two statements about SAN port channels configured on Cisco Nexus 5000 Series switches are true? ()  A、 The bring up protocol automatically detects and overrides any misconfiguration.B、 You can manually configure channel groups, or they can be automatically created.C、 Changes in configuration to the SAN port channel interface must also be made to all members of the channel group.D、 The port channel protocol uses the exchange fabric parameters command to communicate across peer ports in an ISL.E、 The port channel protocol ensures that a set of ports is eligible to be part of the same SAN port channel.

考题 Which three are valid methods to monitor and trend SAN port channels with DCNM?()A、 use summary view in the device managerB、 from the DCNM-SAN client, view ISLs in real time from the Performance drop-down listC、 for each port channel, select Monitor ContinuallyD、 configure traps for each port channel to utilize RMONE、 set up flows with the DCNM-SAN client and use the Performance Manager web client for performance collections

考题 Where are Cisco UCS vNICs created?()   A、 In the blade BIOSB、 In the operating systemC、 In the service profileD、 In the card option ROM

考题 Given the following output:  san-port-channel 12 is up   Hardware is Fibre Channel  Port WWN is 24:0c:00:0d:ec:d3:5c:00   Admin port mode is NP, trunk mode is on   Port mode is NP Port vsan is 1  Speed is 8 Gbps   Member[1] : fc2/3  Member[2] : fc2/4  What does "Speed is 8 Gbps" indicate?()A、 The speed of the slowest interface in the port channelB、 The combined speed of all interfaces configured in the port channelC、 The combined speed of all interfaces in the port channel that are upD、 The speed that can be achieved if all buffers are used

考题 Which port channel command is recommended for N1KV on Cisco UCS?()A、 channel-group auto mode onB、 channel-group auto mode activeC、 channel-group auto mode on sub-group cdpD、 channel-group auto mode on sub-group manualE、 channel-group auto mode on mac-pinning

考题 Which two statements about end-host mode in SAN connectivity in a Cisco UCS environment are true? ()A、 End-host mode is synonymous with NPV mode.B、 In end-host mode, only hard pinning of vHBAs to Fibre Channel uplink ports is allowed.C、 Making configuration changes between Fibre Channel switching mode and end-host mode is nondisruptive.D、 End-host mode is the default Fibre Channel switching mode.

考题 Where are SAN Port Channel is created in UCS Manager?()A、 Under the Admin tab on the FIB、 Under the Server tab in the service profileC、 Under the SAN tab on each VSAND、 Under the Admin tab on the chassisE、 Under the SAN tab on the Fabric Interconnect

考题 Your company wants Server 1/eth0 (vNIC 1) configured so that it always uses Fabric Interconnect A Port Channel 1 (Po1) when it communicates with anything outside of the Cisco UCS domain. However, if vNIC 1 fails over to Fabric Interconnect B using fabric failover, then vNIC 1 can any uplink port on Fabric Interconnect B. Which statements are true? ()A、 The fabric interconnects must be in end-host mode.B、 A pin group must be configured on the server tab in Cisco UCS Manager.C、 In the service profile for Server 1, vNIC 1 must be explicitly assigned to a pin group.D、 Server 1 cannot be configured to meet the requirement. A server can only be manually pinned to a single physical interface and not a port channel because of the LACP load-balancing algorithm.E、 Server 1 cannot be configured to meet the requirement. A server is either manually pinned to an uplink on both fabric interconnects or the server is automatically pinned, but not both.

考题 Which statement about SAN port channels configured on Cisco Nexus 5000 Series Switches is true?()  A、 A single SAN port channel can have both Fibre Channel and virtual Fibre Channel interfaces. B、 SAN port channels can include up to 16 interfaces.C、 SAN port channels distribute traffic across all links in the port channel when source ID and destination ID load balancing are used.D、 The links in SAN port channels can be connected to different sets of switches.E、 The On mode of operation means ports only operate as part of a SAN port channel or remain inactive.

考题 A system administrator has been instructed to attach storage in their client LPARs, in a Power 770, with fibre channel adapters using N_port ID virtualization (NPIV). Which of the following partitions has the minimum requirements to utilize virtual fibre channel?()A、LPAR-A with 1Gb FC HBA and SAN connectionB、LPAR-B with 2Gb FC HBA and SAN connectionC、LPAR-C with 4Gb FC HBA and SAN connectionD、LPAR-D with 8Gb FC HBA and SAN connection

考题 A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()A、Configure 2CFFh combination fibre channel / gigabit Ethernet adaptersB、Configure 1CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterC、Configure 1CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterD、Configure 1CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

考题 A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()A、Configure 2 CFFh combination fibre channel / gigabit Ethernet adaptersB、Configure 1 CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapterC、Configure 1 CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapterD、Configure 1 CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

考题 单选题Where are SAN Port Channel is created in UCS Manager?()A  Under the Admin tab on the FIB  Under the Server tab in the service profileC  Under the SAN tab on each VSAND  Under the Admin tab on the chassisE  Under the SAN tab on the Fabric Interconnect

考题 单选题In a Cisco Unified Computing System, where are SAN port channels connected to?()A  Only to Cisco Fibre Channel switchesB  Only to Cisco Fibre Channel switches in NPIV modeC  To any Fibre Channel switchD  Directly to storage arraysE  Only to Nexus Switches

考题 单选题Where are Cisco UCS vNICs created?()A  In the blade BIOSB  In the operating systemC  In the service profileD  In the card option ROM

考题 单选题Which protocol does the UCS Fabric Interconnect support on port channel uplinks?()A LACPB PAgPC MCPC

考题 多选题What is the use of NPV in Cisco Unified Computing Systems? ()ACompatibility with third-party Fibre Channel switchesBFaster throughputCReduce domain IDs in a Fibre Channel environmentDSupport for increased number of VSANsESupport for SAN port channels

考题 多选题Which two statements about SAN port channels configured on Cisco Nexus 5000 Series switches are true? ()AThe bring up protocol automatically detects and overrides any misconfiguration.BYou can manually configure channel groups, or they can be automatically created.CChanges in configuration to the SAN port channel interface must also be made to all members of the channel group.DThe port channel protocol uses the exchange fabric parameters command to communicate across peer ports in an ISL.EThe port channel protocol ensures that a set of ports is eligible to be part of the same SAN port channel.

考题 单选题Which port channel command is recommended for N1KV on Cisco UCS?()A  channel-group auto mode onB  channel-group auto mode activeC  channel-group auto mode on sub-group cdpD  channel-group auto mode on sub-group manualE  channel-group auto mode on mac-pinning

考题 单选题What interface is created when an FC Port Channel is created on a Cisco Unified Computing System?()A  An interface ’san-port-channel’ in NXOSB  An interface ’port-channel’ in NXOSC  An interface ’port-channel’ with ’mode fc’ configuredD  An interface ’fc-port-channel’ in NXOS

考题 单选题Which statement about SAN port channels configured on Cisco Nexus 5000 Series Switches is true?()A  A single SAN port channel can have both Fibre Channel and virtual Fibre Channel interfaces. B  SAN port channels can include up to 16 interfaces.C  SAN port channels distribute traffic across all links in the port channel when source ID and destination ID load balancing are used.D  The links in SAN port channels can be connected to different sets of switches.E  The On mode of operation means ports only operate as part of a SAN port channel or remain inactive.

考题 单选题What is the appliance port used to connect to in a Cisco Unified Computing System?()A  Fibre Channel storageB  UCS C-Series serversC  NFS storageD  UCS chassisE  Other fabric interconnect