单选题
A System z customer is planning to deploy the IBM System Storage DS6800 in each of threesmall data centers located around a large city. A backup data center with an IBM System StorageDS8100 will serve as the disaster recovery facility. Which advanced function can the customerimplement to meet disaster recovery requirements?()
A
Global Mirror for zSeries
B
Metro Mirror
C
Global Copy
D
Metro/Global Mirror
参考答案
参考解析
解析:
暂无解析
更多 “单选题A System z customer is planning to deploy the IBM System Storage DS6800 in each of threesmall data centers located around a large city. A backup data center with an IBM System StorageDS8100 will serve as the disaster recovery facility. Which advanced function can the customerimplement to meet disaster recovery requirements?()A Global Mirror for zSeriesB Metro MirrorC Global CopyD Metro/Global Mirror” 相关考题
考题
Using the following information: Performance data from an existing system that a new system will replace; Performance estimates that anticipate future workloads; Micro-partitioning and logical partitioning implementations. Which of the following allows a technical sales representative to create a system design which can be imported into an HMC?()A、IBMeConfigB、IBM Performance MonitorC、IBM Workload Estimator (WLE)D、IBM System Planning Tool (SPT)
考题
A bank has requested proposals for a storage solution to upgrade their disaster recoveryprocesses for their System z, UNIX, and Microsoft Windows environment. The solution mustsimulate a multi-site environment and provide the customer the ability to explore Metro Mirror,Global Mirror, Global Mirror for z/OS, and FlashCopy. Floor space is limited. Which solution bestmeets the specified requirements?()A、Two IBM System Storage DS8100 systemsB、One IBM System Storage DS8300 with two LPARsC、Two IBM System Storage DS6800 systems in a single rackD、One IBM System Storage DS6800 for System z, and SVC for UNIX and Windows
考题
A bank has requested proposals for a storage solution to implement disaster recovery processes for their IBM System z configured with Linux, IBM System p configured with AIX, and Microsoft Windows environments. The solution must simulate a multi-site environment and provide the customer the ability to evaluate Metro Mirror, Global Mirror, and FlashCopy. Floor space is limited. What hardware platform provides this native support?()A、IBM XIV Storage SystemB、IBM System Storage DS5300C、IBM System Storage DS8800D、IBM System Storage DS5020 with SVC
考题
A customer has an EMC Symmetrix DMX3000 that is at the end of lease. The environment consists of IBM System p, IBM System i, and IBM System z. The customer is evaluating EMC, HDS, and IBM storage as possible replacements. They are interested in comparing the performance of all three disk subsystems. Which tool compares performance()A、Capacity MagicB、eConfigC、TPC for DiskD、Disk Magic
考题
A customer wants to consolidate storage from four IBM System p servers and one large IBM System i server. The customer does not have a SAN installed. The customer will require approximately 4 TB for System p and 3 TB for System i. The customer states that performance and isolation of the System i system is most important. Capacity, multi-path access, and replication functions are important for the System p servers. Which solution best satisfies the customer requirements()A、IBM System Storage DS8100 with 300 GB drives for the System p, 73 GB/15k drives for System i, and advanced functions for System p capacityB、IBM System Storage DS8300 with LPAR, 73 GB/15k drives for System i, and 300 GB drives and advanced functions for System p capacityC、IBM System Storage DS6800 with direct attach, 73 GB/15k drives for System i performance, and 300 GB drives and advanced functions for System pD、IBM System Storage DS6800 with LPAR, 146 GB/15k drives for System i, 500 GB FATA drives for System p
考题
A customer wants to consolidate storage from four IBM System p servers and one large IBM System i server on a high end disk subsystem. The customer does not have a SAN installed. The customer will require approximately 24 TB of capacity for System p and 20 TB of capacity for System i. The customer states that performance of the System i system is most important. Capacity, multi-path access, and replication functions are important for the System p servers. Which solution best satisfies the customer requirements()A、IBM DS8700 with 600 GB drives for the System p, 300 GB/15k drives for Systemi; and advanced functions for System p capacityB、IBM DS8700 with LPAR, 300 GB/15k drives and RAID 10 for Systemi; and 600GB drives with RAID 5 and advanced functions for System p capacityC、IBM DS8700 with advanced functions, 300 GB/15k drives and RAID 10 for Systemi performance; and 600 GB drives and RAID 5 for System p capacityD、IBM DS5100 with Enhanced Remote Mirror, 600GB/15k drives and RAID 5 for System p; and 300GB/15k drives and RAID 10 for Systemi
考题
A customer wants to install a pSeries system into an OEM rack. What critical information is provided in the Site and Hardware Planning Information manual?()A、System dimensions and weight, system power and cooling requirements, and list of supported OEM racksB、System dimensions and weight, list of supported OEM racks, and requirements for installing IBM systems into OEM racksC、System performance specs, system power and cooling requirements, and requirements for installing IBM systems into OEM racksD、System dimensions and weight, system power and cooling requirements, and requirements for installingIBM systems into OEM racks
考题
A customer has a storage requirement for a mixed IBM System p and System z environment. They require approximately 2 TB of high performance disk for their System z environment. They require approximately 25 TB of low-performance disk for their System p environment. The storage specialist is using Capacity Magic to configure an IBM System Storage DS8300. Which configuration is most appropriate for this customer()A、4 x 73 GB 15k rpm disk drive sets for System z; and 4 x 500 GB 7.2k rpm disk drive sets for System pB、4 x 146 GB 15k rpm disk drive sets for System z; and 2 x 500 GB 7.2k rpm disk drive sets for System pC、2 x 300 GB 10k rpm disk drive sets for System z; and 4 x 300 GB 10k rpm disk drive sets for System pD、2 x 73 GB 15k rpm disk drive sets for System z; and 2 x 500 GB 7.2k rpm disk drive sets for System p
考题
An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN that is now configured with an EMC Symmetrix subsystem disk. The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A、IBM System Storage DS8000: Host Systems Attachment GuideB、DS8000 Interoperability MatrixC、IBM System Storage DS8000: Introduction and Planning GuideD、IBM System Storage Solution Handbook
考题
During a review of environmental requirements before ordering an IBM System z9 server and IBM System Storage DS8700, the customer states that the available power is 220 volts AC. Which feature should be included with the DS8700 order() A、Low VoltageB、High VoltageC、Remote System z Power ControlD、Battery Assembly
考题
Which of the following can deploy system plans generated by the IBM System Planning Tool (SPT)?()A、 The Hardware Management Console (HMC) and Integrated Virtualization Manager (IVM).B、 The Hardware Management Console (HMC) and Advanced System Manager Interface (ASMI).C、 Integrated Virtualization Manager (IVM) and Advanced System Manager Interface (ASMI).D、 Integrated Virtualization Manager (IVM) and BladeCenter Advanced Management Module (AMM).
考题
A sales team has proposed an IBM System Storage DS8100 configured with 10 TB, split equallybetween IBM System z and IBM System p. The System z environment requires point-in-time copyand the System p environment does not. For the System z environment, 3 TB have beenconfigured with an additional 2 TB for point-in-time copy. What is the least expensive licensescope for point-in-time copy?()A、All and 10 TBB、CKD and 2 TBC、CKD and 5 TBD、CKD and 10 TB
考题
A customer has a POWER6 520 system with 6 partitions. They plan to upgrade their system and need to determine the current hardware configuration of the partitions before making any upgrade decisions. What is needed to read the exported system plan and design the new system?()A、e-ConfigB、System Planning Tool (SPT)C、IBM Workload Estimator (WLE)D、IBM Performance Monitor (PM)
考题
A customer asks for the thermal load (BTU/hr) to determine whether their existing cooling system will support the IBM System Storage DS8000. Where can the sales representative find this information()A、IBM System Storage DS8000: Introduction and Planning GuideB、IBM DS8000 Interoperability Matrix on the support page on the webC、IBM System Storage DS8000: User’s GuideD、IBM System Storage DS8000: Solution Assurance Guide
考题
A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers. What is the best document the Business Partner can suggest to accomplish this requirement()A、the IBM System Storage DS8000 Interoperability MatrixB、the IBM System Storage DS8000 Introduction and Planning GuideC、the IBM System Storage DS8000 Host System Attachment GuideD、the IBM System Storage DS8000 User’s Guide
考题
A customer wants to purchase an IBM System Storage DS8000. The proposed location is in a data center on the third floor of an office building. Which document should the storage specialist consult to ensure that the DS8000 can be installed in the proposed location()A、IBM Announcement LettersB、IBM DS8000 Installation GuideC、IBM DS8000 Introduction and Planning GuideD、IBM Systems Storage Solutions Handbook
考题
A customer plans to order several new pSeries systems and is concerned that the additional heat load may overwhelm the current air-handling system. How might the pSeries technical specialist aid the customer in addressing their concern?()A、Direct the customer to the Installation Guide for each system to identify the power requirements.B、Direct the customer to engage their site personnel to ensure the proper power connectors are provided to support the systems.C、Direct the customer to the Site and Hardware Planning Information and review the system requirements for each new pSeries system.D、Direct the customer to the Site and Hardware Planning Information to confirm that enough space is available in the rack to allow for proper airflow.
考题
A bank has requested proposals for a storage solution to upgrade their disaster recovery processes for their IBM System z, UNIX, and Microsoft Windows environment. The solution must simulate a multi-site environment and provide the customer the ability to evaluate Metro Mirror, Global Mirror, Global Mirror for z/OS, and FlashCopy. Floor space is limited. Which solution best meets the specified requirements()A、two IBM System Storage DS8100 systemsB、one IBM System Storage DS8300 with LPARC、two IBM System Storage DS6800 systems in a single rackD、one IBM System Storage DS6800
考题
A customer has a storage requirement for a mixed IBM Power AIX and System z environment. They require approximately 3 TB of high performance disk for their System z environment. They require approximately 32 TB of low-performance disk for their System p environment. The storage specialist is using Capacity Magic to configure an IBM DS8700. Which configuration is most appropriate for this customer()A、2 x 300 GB 15k rpm disk drive sets for System z; and 4 x 2 TB 7.2k rpm disk drive sets for Power AIXB、4 x 146 GB 15k rpm disk drive sets for System z; and 4 x 2 TB 7.2k rpm disk drive sets for Power AIXC、2 x 300 GB 10k rpm disk drive sets for System z; and 4 x 300 GB 15k rpm disk drive sets for Power AIXD、2 x 300 GB 15k rpm disk drive sets for System z; and 2 x 1 TB 7.2k rpm disk drive sets for Power AIX
考题
A UNIX customer has a Symmetrix DMX that has crashed three times in the past six months, causing data loss. The customer is shopping for an enterprise storage solution to provide point-in- time copy functionality without a fixed relationship to its primaries. Which IBM solution best meets this customer’s requirements()A、IBM System Storage DS8700 andVolumeCopyB、IBM System Storage DS8700 andFlashCopyC、IBM System Storage DS8700 andFlashCopy with the NoCopy optionD、IBM System Storage DS8700 andFlashCopy with the Persistent option
考题
单选题A customer asks for the thermal load (BTU/hr) to determine whether their existing cooling system will support the IBM System Storage DS8000. Where can the sales representative find this information()A
IBM System Storage DS8000: Introduction and Planning GuideB
IBM DS8000 Interoperability Matrix on the support page on the webC
IBM System Storage DS8000: User’s GuideD
IBM System Storage DS8000: Solution Assurance Guide
考题
单选题A customer wants to install a pSeries system into an OEM rack. What critical information is provided in the Site and Hardware Planning Information manual?()A
System dimensions and weight, system power and cooling requirements, and list of supported OEM racksB
System dimensions and weight, list of supported OEM racks, and requirements for installing IBM systems into OEM racksC
System performance specs, system power and cooling requirements, and requirements for installing IBM systems into OEM racksD
System dimensions and weight, system power and cooling requirements, and requirements for installingIBM systems into OEM racks
考题
单选题A customer wants to consolidate storage from four IBM System p servers and one large IBM System i server. The customer does not have a SAN installed. The customer will require approximately 4 TB for System p and 3 TB for System i. The customer states that performance and isolation of the System i system is most important. Capacity, multi-path access, and replication functions are important for the System p servers. Which solution best satisfies the customer requirements()A
IBM System Storage DS8100 with 300 GB drives for the System p, 73 GB/15k drives for System i, and advanced functions for System p capacityB
IBM System Storage DS8300 with LPAR, 73 GB/15k drives for System i, and 300 GB drives and advanced functions for System p capacityC
IBM System Storage DS6800 with direct attach, 73 GB/15k drives for System i performance, and 300 GB drives and advanced functions for System pD
IBM System Storage DS6800 with LPAR, 146 GB/15k drives for System i, 500 GB FATA drives for System p
考题
单选题A customer is sharing an IBM System Storage DS8300 for both IBM System z and Systemapplications. They need to provide data recovery capability between the primary and the remotedata center, which is 60 kilometers away. Which copy service keeps all data synchronized at theremote data center?()A
Concurrent CopyB
FlashCopyC
Metro MirrorD
Global Mirror
考题
单选题An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN that is now configured with an EMC Symmetrix subsystem disk. The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A
IBM System Storage DS8000: Host Systems Attachment GuideB
DS8000 Interoperability MatrixC
IBM System Storage DS8000: Introduction and Planning GuideD
IBM System Storage Solution Handbook
考题
单选题A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers. What is the best document the Business Partner can suggest to accomplish this requirement()A
the IBM System Storage DS8000 Interoperability MatrixB
the IBM System Storage DS8000 Introduction and Planning GuideC
the IBM System Storage DS8000 Host System Attachment GuideD
the IBM System Storage DS8000 User’s Guide
考题
单选题Which of the following can deploy system plans generated by the IBM System Planning Tool (SPT)?()A
The Hardware Management Console (HMC) and Integrated Virtualization Manager (IVM).B
The Hardware Management Console (HMC) and Advanced System Manager Interface (ASMI).C
Integrated Virtualization Manager (IVM) and Advanced System Manager Interface (ASMI).D
Integrated Virtualization Manager (IVM) and BladeCenter Advanced Management Module (AMM).