With reference to the requirements under IMO MODU CODE,Space in which an explosive gas/air mixture is likely to occur in normal operation of Drilling Units is considered as().

  • A、Zone0
  • B、Zone1
  • C、Zone2
  • D、Zone3

参考答案

更多 “With reference to the requirements under IMO MODU CODE,Space in which an explosive gas/air mixture is likely to occur in normal operation of Drilling Units is considered as().A、Zone0B、Zone1C、Zone2D、Zone3” 相关考题
考题 Which of the following problems can occur if you continually fail to drain off condensate from a starting air receiver?A.Corrosion and eventual failure of the tankB.Gumming of the tank relief valvesC.Immediate failure of components downstream of the compressed air systemD.Boiling of the water oil mixture as pressure is reduced

考题 One of the disadvantages of using carbon dioxide to extinguish a fire in an enclosed space isA.the 'snow' which is sometimes discharged along with the gas is toxicB.prolonged exposure to high concentrations of CO2 gas causes suffocationC.rapid dissipation of the CO2 vaporD.the CO2 gas is lighter than air and a large amount is required to extinguish a fire near the deck

考题 Which of the following conditions is true concerning a flammable liquid with a concentration above the upper explosive limit?A.The mixture is too lean to burnB.The mixture is too rich to burnC.The vapor is about to explodeD.Conditions are perfect for combustion

考题 The(auto)ignition temperature is that temperature at which ______.A.No spark or flame is required to ignite gas or vaporB.A fuel begins to give off explosive vaporsC.A fuel if ignited will continue to burnD.A 1% mixture of the fuel with air will explode

考题 A fuel-air mixture below the lower explosive limit is too ______.A.Rich to burnB.Lean to burnC.Cool to burnD.Dense to burn

考题 Due to the large amount of heat picked up by the air in boiler and engine rooms, it would be impracticable to maintain ambient conditions within the comfort zone by air conditioning or any other means. The normal practice is to provide copious mechanical ventilation; in boiler rooms, the quantity is equated to the combustion requirements, while in a motor ship engine room the supply may be 25-50% in excess of the requirements of the engines.The axial flow fan is particularly suited to handle these large air volumes at the moderate pressures required, while of course the “straight-through” flow feature places it at an advantage over the centrifugal fan.The increasing adoption of automation, with the provision of a separate control room makes less significant the fact that comfort conditions cannot be maintained in the engine room all the time. Which of the following devices should be taken to maintain ambient conditions of the boiler and machinery space?A.air compressorB.air coolerC.air-conditioning plantD.mechanical ventilation plant

考题 The emergency source of power for Mobile Offshore Drilling Units should be capable, having regard to starting currents and the transitory nature of certain loads, of supplying simultaneously at least the services specified in 5.3.6 of the 1989 MODU Code. Which one of the following service is not required to be supplied from the emergency power for a period of 18 hours?()A、Emergency lighting at every embarkation station on deck and over sidesB、Emergency lighting at the storage positions for firemen’s outfitsC、Fire and gas detection and their alarm systemD、Power to operate the watertight doors and their indicators

考题 单选题A diesel engine is turned at normal cranking speed, but fails to fireThis can occur from ()A low lube oil temperatureB low starting air temperatureC air in the fuel injectionD water in the starting air system

考题 单选题A fuel-air mixture below the lower explosive limit is too().A rich to burnB lean to burnC cool to burnD dense to burn

考题 单选题How does an inert gas system on a tanker function to prevent explosions in cargo tanks? ()A De-energizes the charged mist effectB Maintains a positive pressure on the vent header to cool the flammable vaporsC Inert gas filters out the flammable vapors from the cargo tank spacesD Inert gas dilutes the flammable vapor and air concentrations to keep them below the lower explosive limit

考题 单选题On opposite ends of a single shaft of a turboblower are a gas driven ()and a air compressor, which are sealed each other.A charge air receiverB scavenging air beltC turbineD air cooler

考题 单选题The (auto)ignition temperature is that temperature atwhich().A no spark or flame is required to ignite gas or vaporB a fuel begins to give off explosive vaporsC a fuel if ignited will continue to burnD a 1% mixture of the fuel with air will explode

考题 单选题Air conditioning is the process of treating air to control () its temperature, humidity, cleanliness and distribution to meet the comfort requirements of the occupants of the conditioned space.A instantaneousB instantaneouslyC simultaneousD simultaneously

考题 单选题Under the regulations implementing MARPOL, a mobile offshore drilling unit is required to have an International Oil Pollution Prevention (IOPP) certificate when the unit ().A is drilling on the Outer Continental ShelfB moves to a new drilling location in U-SwatersC engages in a voyage to a port of another country which is a party of MARPOLD All of the above

考题 单选题The International Regulations for Preventing Collisions at Sea contain the requirements for ().A lights that must be displayed on anchor buoysB the display of load line markingsC minimum horsepower for tugs involved in rig movesD lighting of mobile offshore drilling units being towed

考题 单选题Which mooring line is likely to undergo the most strain when docking a ship under normal conditions?()A Bow lineB Breast lineC Spring lineD Stern line

考题 单选题Gas exchange, which is a basic part of the cycle of an internal combustion engine, is()A the supply of normal air and removal of compressed airB the supply of fuel oil and combustion of the atomized oilC the supply of fresh air and removal of exhaust gasesD the supply of fresh air and removal of the extra heat

考题 单选题Which of the following problems can occur if you continually fail to drain off condensate from a starting air receiver?()A Corrosion and eventual failure of the tankB Gumming of the tank relief valvesC Immediate failure of components downstream of the compressed air systemD Boiling of the water oil mixture as pressure is reduced

考题 单选题Combustible gas indicators measure the presence of combustible gas as a percentage of the().A flash pointB upper explosive limitC lower explosive limitD fire point

考题 单选题If the diesel fuel vapors present are within the flammable range ().A the vapor air mixture is too rich to burnB an explosion may occur if a source of ignition is presentC the vapor air mixture is too lean to bum the upper explosiveD limit has been exceeded

考题 单选题Which condition is necessary for a substance to burn?()A The temperature of the substance must be equal to or above its fire pointB The air must contain oxygen in sufficient quantityC The mixture of vapors with air must be within the explosive rangeD All of the above

考题 单选题Which of the following is wrong about operation of oily water separator?()A filled with clean water before operationB keep air cushion in oil collecting space during runningC check oil level during runningD clean inner separator with low pressure stream

考题 单选题One of the disadvantages of using carbon dioxide to extinguish a fire in an enclosed space is ().A the snow which is sometimes discharged along with the gas is toxicB prolonged exposure to high concentrations of C02 gas causes suffocationC rapid dissipation of theC02 vaporD the C02 gas is lighter than air and a large amount is required to extinguisha fire near the deck

考题 单选题Which of the following conditions is true concerning a flammable liquid with a concentration above the upper explosive limit?()A The mixture is too lean to burnB The mixture is too rich to burnC The vapor is about to explodeD Conditions are perfect for combustion

考题 单选题With reference to the requirements under IMO MODU CODE,Operating manuals containing guidance for the safe operation of the MODU unit for both normal and envisaged emergency conditions, to the satisfaction of the Administration should be provided on board and be readily available to all concerned. The manuals should, in addition to providing the necessary general information about the unit, contain guidance on and procedures for the operations that are vital to the safety of personnel and the unit.The operating manual for normal operations should include the following general descriptive information()A a description and particulars of the unitB a capacity plan showing the capacities and the vertical, longitudinal and transverse centers of gravity of tanks and bulk material stowage spacesC Fuel oil storage and transfer proceduresD All of above

考题 单选题With reference to the requirements under IMO MODU CODE,Space in which an explosive gas/air mixture is likely to occur in normal operation of Drilling Units is considered as().A Zone0B Zone1C Zone2D Zone3

考题 单选题The minimum concentration of a vapor in air which can form an explosive mixture is called the().A auto-ignition pointB flash pointC lower explosive limit (LEL)D threshold limit value (TLV)