If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().
A

system was overcharged with refrigerant

B

system was low on refrigerant

C

suction valves were leaking slightly

D

relief valve was leaking slightly


参考答案

参考解析
解析: 暂无解析
更多 “单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A system was overcharged with refrigerantB system was low on refrigerantC suction valves were leaking slightlyD relief valve was leaking slightly” 相关考题
考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow

考题 Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur when the compressorA.has run continuously for a long periodB.suction pressure is below normalC.oil level is below normalD.starts after a long idle period

考题 If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch

考题 If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress

考题 Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

考题 If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

考题 单选题The sudden reduction of pressure occurring within the crankcase of a refrigeration compressor during starting causes the ().A sudden evaporation of wax crystals in the lubricantB sudden evaporation of entrapped air in the lubricantC release of refrigerant from the oil/refrigerant mixtureD release of dissolved lubricant from the refrigerant

考题 单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().A a shortage of refrigerant in the systemB air in the systemC an accumulation of liquid refrigerant in the crankcaseD a shortage of oil in the crankcase

考题 单选题If a refrigeration system compressor crankcase is sweating, you should ().A add refrigerant to the systemB adjust the thermal expansion valve to the proper settingC adjust the float valve to the proper holding pressureD open the hand expansion valve

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().A overheated compressor bearingsB excess lube oil viscosityC carbon deposits on the compressor piston ringsD wax crystals forming in the lubricant

考题 单选题Short cycling of a refrigeration compressor refers to ().A frequently grounding outB frequently starting and stoppingC running too fastD running too slow

考题 单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A purge the condenser if the waterside is dirtyB check for proper water flow through the condenserC increase the high pressure cutout settingD reduce the cooling water flow

考题 单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A system was overcharged with refrigerantB high pressure switch was improperly adjustedC expansion valve strainers were fouledD suction valves were leaking slightly

考题 单选题If a refrigeration system were short of refrigerant, the condition would result in ().A continuous running of the compressorB high suction pressureC high discharge pressureD short cycling of the compressor on the water failure switch

考题 单选题()are supplied by main switchboard directly.A Suez Canal searchlight, air compressor and air conditioning compressorB Air compressor, boiler blower and refrigeration plantC Boiler blower, Suez Canal searchlight and refrigeration plantD Suez canal searchlight, air compressor and boiler blower

考题 单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A system is low on refrigerantB high pressure cutout switch is improperly adjustedC discharge valves are leaking slightlyD discharge valves are leaking excessively

考题 单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A always be wide open when the compressor restartsB continue to operate as if the system were in operationC remain open until evaporator pressure equalizes, then close until the compressor restartsD always be completely closed until the compressor restarts

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A refrigerant boiling out of solution from the lube oilB liquid refrigerant flooding the compressor and systemC lube oil viscosity being reduced by refrigerant dilutionD compressor suction pressure suddenly increasing

考题 单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A refrigerant overchargeB overfeeding by the expansion valveC a restricted suction strainerD due to short cycling of the compressor

考题 单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A system is overcharged with refrigerantB system is low on refrigerantC discharge valves are leaking excessivelyD discharge valves are leaking slightly

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A compressor damage from improper lubricationB refrigerant absorption by the lubricantC increased viscosity in the lubricantD carbon deposit on the compressor suction valves

考题 单选题In the () refrigeration compressor one end of the crank shaft extends through the crankcase house for connection, via a coupling or pulley, to an external drive motor.A open-typeB hermeticC semi-hermeticD all the above

考题 单选题An increase in the heat load to a refrigeration system will cause ().A the suction pressure to decreaseB the suction temperature to increaseC increased ice formation on the evaporator coilD excessive short cycling of the compressor

考题 单选题Sweating of the refrigeration system compressor crankcase is caused by ().A too much superheatB insufficient superheatC suction pressure too lowD excessive refrigerant returning to the compressor

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.A has continuously for a long periodB suction pressure is below normalC oil level is below normalD starts after a long idle period