网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()
A

2

B

4

C

6

D

8


参考答案

参考解析
解析: 暂无解析
更多 “单选题A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()A 2B 4C 6D 8” 相关考题
考题 A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation.What multipathing driver is required to build a redundant solution?()A.RDACB.MPIOC.SSPCD.SDDPCM

考题 A customer is running Microsoft Windows 2003, Sun Solaris, and IBM AIX with a total capacity of20 TB. This customer needs high availability for e-business applications. The servers are currently connected to two EMC Symmetrix subsystems that are running RAID 1. The customer wants to consolidate all storage into an IBM System Storage DS8700. How many Fibre Channel drive sets are needed to satisfy the total capacity for this customer?()A、8 drive sets of 300 GB drivesB、4 drive sets of 300 GB drivesC、14 drive sets of 146 GB drivesD、18 drive sets of 146 GB drives

考题 A customer wants to consolidate storage from four IBM System p servers and one large IBM System i server. The customer does not have a SAN installed. The customer will require approximately 4 TB for System p and 3 TB for System i. The customer states that performance and isolation of the System i system is most important. Capacity, multi-path access, and replication functions are important for the System p servers.    Which solution best satisfies the customer requirements()A、IBM System Storage DS8100 with 300 GB drives for the System p, 73 GB/15k drives for System i, and advanced functions for System p capacityB、IBM System Storage DS8300 with LPAR, 73 GB/15k drives for System i, and 300 GB drives and advanced functions for System p capacityC、IBM System Storage DS6800 with direct attach, 73 GB/15k drives for System i performance, and 300 GB drives and advanced functions for System pD、IBM System Storage DS6800 with LPAR, 146 GB/15k drives for System i, 500 GB FATA drives for System p

考题 A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation. What multipathing driver is required to build a redundant solution?()A、RDACB、MPIOC、SSPCD、SDDPCM

考题 An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A、IBM System Storage DS8000: Host Systems Attachment GuideB、DS8000 Interoperability MatrixC、IBM System Storage DS8000: Introduction and Planning GuideD、IBM System Storage Solution Handbook

考题 An SMB customer is looking for a low cost, easy to install and configure, entry-level SAN solution to attach to five rack-mounted System x Servers.  Which storage solution would be best for this customer?()A、EXP3000 Local Attached Storage EnclosuresB、DS4000 Series storage solutionC、DS3000 Series Storage solutionD、DS4800 Storage Solution

考题 An existing IBM customer has some iSeries servers in their environment.  The customer is adding an x366 server with an RSA-II installed for their Microsoft Client/Server applications.  The customer wants to consolidate the storage and centralize the backup of the iSeries and xSeries platforms.  Which of the following will accomplish this?()A、Share the data over the Ethernet LAN.B、Install the IXA Adapter in the iSeries server.C、Install the IXA Adapter in the xSeries server.D、Attach both servers to an IXS switch.

考题 A company wants to replace their Dell servers and implement x445 servers with a Storage Area Network (SAN).  They will add an IBM TotalStorage DS4500 and EXP710s for their storage requirements.  The customer’s goal is to reduce the Total Cost of Ownership (TCO) of their current environment.  Which of the following factors provide the greatest advantage?()A、The DS4500 with DS4000 Storage Manager provides efficient storage utilization.B、The DS4500 and x445 provide disaster recovery capability.C、The IBM TotalStorage DS4500 includes virtualization of the disk storage.D、Storage partitioning and Remote Volume Mirroring are standard features with the DS4500 product.

考题 A customer currently buys HP ProLiant servers and EMC storage. The customer has encountered various problems getting certain servers to work with their storage.  Which of the following arguments can the Sales Specialist present to best position IBM? ()A、IBM’s ServerProven program is a reference that assures a customer of compatibility with specific third-party products.B、IBM sells other vendors’ products and will test compatibility with the customer’s products. C、B IBM’s storage division regularly tests their products with other vendors’ server products.  D、IBM’s server division regularly tests their products with other vendors’ storage products.

考题 A customer needs to deploy ten dual processor Xeon servers.  Six servers will be running Linux and Apache, and the other four will be Citrix presentation servers.  The customer’s main concerns are the rack space and the option to have SATA drives.  The maximum memory required is 8GB.  Which of the following options will provide the best price and performance?()A、Ten x306’s with internal SATA drivesB、Five x346’s with internal SATA drives and VMWare ESX ServerC、Five x366’s partitioned into two VMs each with VMWare ESX ServerD、Ten x336’s with internal SATA drives

考题 A customer wants to deploy VMWare ESX on four-way Intel systems.  They are considering IBM and Dell.Which of the following is an advantage IBM has over the competition?()A、IBM provides optional Remote Technical Support for hardware, NOS, and VMWare.B、The IBM xSeries EXA chipset has extensions to provide better efficiency for the VMFS file system.C、IBM servers can address larger LUNs on SAN storage than Dell.D、IBM provided VMWare with the majority of their internal drivers for ESX.

考题 A customer has 12 x445s and 20 x365s in their datacenter that are dedicated to production workloads.  The customer wants to standardize on IBM Director as their Intel environment systems management platform.  Which server platform is supported as a Director server?()A、zSeriesB、pSeriesC、iSeriesD、iSeries with IXA Adapter

考题 A customer runs an application on a supported 8-way x445.  The customer needs to monitor operations and wants to be alerted when problems arise.  Which TWO of the following can be configured in IBM Director Base Pack to monitor the customer’s operations?()A、Fan operationB、Bottleneck analysisC、Power supply operationsD、Planned versus unplanned outagesE、Application predictive failure analysis

考题 A customer wants to deploy the latest ServeRAID driver and firmware updates to 25 servers on their LAN.  This needs to be accomplished during off peak hours when LAN utilization is at its lowest.  Which IBM Director component would be used to accomplish this?()A、Update Express CDB、Update AssistantC、Process ManagementD、Remote Deployment Manager

考题 A customer wants to improve the utilization of the current capacity of their existing N series Tier 1production storage. What solution would the storage specialist discuss with the customer?()A、 compression with IBM Real-time Compression Appliances B、 deduplication with IBM ProtecTIER C、 virtualization with IBM SVC D、 file virtualization with SONAS

考题 A customer is running a number of non-IBM servers purchased two years ago and has settled on one of the new IBM xSeries servers as a migration path.  From the following options, which is the preferred migration path?()A、Copy the image of the non-IBM servers and copy that image to the IBM servers, then reboot the IBM servers.B、Copy the image from the non-IBM servers with RDM and install them with IBM Director to the new IBM servers. Reboot the IBM servers.C、Install a fresh operating system using ServerGuide, and then install the applications and copy the data from the old servers.D、Install a fresh operating system on the IBM servers and then run ServerGuide on the IBM servers to migrate the applications and data to the IBM servers.

考题 A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the internal fibre switches. Consequently. the customer wants to use the Optical Pass-Thru Module (OPM).  What TRUE statement should be mentioned to the customer regarding the OPM?()A、You can not put the Optical Pass-Thru Module in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch.B、Using blade servers with the Optical Pass-Thru Module will require more fibre ports on the external fibre switch.C、The Optical Pass-Thru Module does not provide the customer with an opportunity to reuse their fibre switch.D、The blade servers do not work with the Optical Pass-Thru Module.

考题 A customer has the following non-virtualized servers: - three Exchange servers, each with 2.8 TB database  - five System i Domino servers, each with 2 TB database  - 20 TB usable capacitySun/SAP cluster  - 70 TB usable capacity of System p requirement  - annual growth rate of 12 TB usable capacity per year   What is the most cost-effective solution for three years()A、IBM System Storage DS5020 with 300 GB drivesB、IBM System Storage DS5300 with 300 GB drivesC、IBM System Storage DS8700 with 300 GB drivesD、IBM System Storage DS5020 with 1 TB SATA drives

考题 A customer wants to directly attach five servers to an IBM System Storage DS8100. They do not intend to use any SAN switches and would like the servers to have a redundant connection to the IBM DS8100. What is the minimum number of DS8000 host adapter cards that the customer will require()A、2B、4C、6D、8

考题 A customer RFP requires installation of an open system SAN and migration of 40 TB currently residing on ten UNIX servers (on internal server disk). The Service Level Agreement (SLA) requires no more than five minutes per week of planned downtime for backup.  Which IBM System Storage solution is the most cost effective()A、an IBM System Storage DS8700 with LTO tape driveB、an IBM System Storage DS8700 with FlashCopy ManagerC、an IBM XIV Storage SystemD、an IBM XIV Storage System with SAN Volume Controller

考题 单选题An existing IBM customer has some iSeries servers in their environment.  The customer is adding an x366 server with an RSA-II installed for their Microsoft Client/Server applications.  The customer wants to consolidate the storage and centralize the backup of the iSeries and xSeries platforms.  Which of the following will accomplish this?()A Share the data over the Ethernet LAN.B Install the IXA Adapter in the iSeries server.C Install the IXA Adapter in the xSeries server.D Attach both servers to an IXS switch.

考题 单选题A customer has bought an IBM System Storage DS8700 and wants to attach ten SuSE Linux Enterprise Server hosts to the DS8700 with multiple paths.  What is the Multipathing Driver the customer needs()A PowerPathB Subsystem Device Driver Device Specific ModuleC Subsystem Device Driver Path Control ModuleD DeviceMapper Multipath

考题 单选题An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A IBM System Storage DS8000: Host Systems Attachment GuideB DS8000 Interoperability MatrixC IBM System Storage DS8000: Introduction and Planning GuideD IBM System Storage Solution Handbook

考题 单选题A retail customer wants to identify the system firmware version information on several IBM System x servers and apply updates as required from a central location without causing server downtime. Which IBM tool provide this capability?()A CDATB Systems DirectorC Server GuideD Tivoli Provisioning Manager for Operational System Deployment (TPMfOSD)

考题 单选题A customer currently buys HP ProLiant servers and EMC storage. The customer has encountered various problems getting certain servers to work with their storage.  Which of the following arguments can the Sales Specialist present to best position IBM? ()A IBM’s ServerProven program is a reference that assures a customer of compatibility with specific third-party products.B IBM sells other vendors’ products and will test compatibility with the customer’s products. C B IBM’s storage division regularly tests their products with other vendors’ server products.  D IBM’s server division regularly tests their products with other vendors’ storage products.

考题 多选题A customer runs an application on a supported 8-way x445.  The customer needs to monitor operations and wants to be alerted when problems arise.  Which TWO of the following can be configured in IBM Director Base Pack to monitor the customer’s operations?()AFan operationBBottleneck analysisCPower supply operationsDPlanned versus unplanned outagesEApplication predictive failure analysis

考题 单选题The pSeries sales representative has done an excellent job in educating the customer on the benefits of working with IBM.  The customer is planning to implement their first ERP application.  This new application will be critical to running their business.  The customer has only a competitor’s UNIX systemcurrently installed.  They are interested in obtaining a proposal from IBM. In addition to the AIX hardware and HACMP software, what else should be included in the IBM proposal for the new ERP solution?()A I/T services and education to help with the implementation of the hardware and softwareB A Supportline specialist to work directly with the customer to manage any issues that ariseC The services required to move the currently installed applications from the competitor’s systems to the IBM systemsD A slimmed down solution to ensure that the IBM solution is less expensive than the competitor’s solution