网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
Before shutting off the fuel supply to stop a medium or high–speed diesel engine, why is it necessary to allow the engine to idle for a few minutes?()
A

To prevent internal damage form local overheating

B

To ensure the fuel nozzles are flushed clean

C

To clear the smoke stack

D

To let the waste heat boiler reduce its rate of steam generation


参考答案

参考解析
解析: 暂无解析
更多 “单选题Before shutting off the fuel supply to stop a medium or high–speed diesel engine, why is it necessary to allow the engine to idle for a few minutes?()A To prevent internal damage form local overheatingB To ensure the fuel nozzles are flushed cleanC To clear the smoke stackD To let the waste heat boiler reduce its rate of steam generation” 相关考题
考题 The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

考题 For most diesel propulsion and generator engines, the over-speed trip device will stop the engine byA.moving the governor control to stopB.shutting off the lubricating oil supplyC.tripping the governor emergency stop leverD.shutting off the fuel supply

考题 The main propulsion diesel continues running after you try to shut down. You should now attempt to .A.stop the fuel oil booster pumpB.engage the jacking gearC.secure the lube oil pumpD.shut off the fuel at the settling tank

考题 Before engaging the turning gear and turning the diesel engine, which of the following operation should be done except______.A.open the indicator cocksB.supply some CYL.Oil to cylinder liner wall with lubricator (only for two stoke diesel engine)C.put the fuel handle in the "stop" positionD.pump up the air bottle

考题 When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.A.increase the fuel oil temperatureB.decrease the fuel oil temperatureC.decrease the fuel oil supply pressureD.increase the air supply

考题 While off-loading from an offshore supply vessel with the crane,the wind increases in strength and changes direction significantly,you should ______.A.Expedite off-loadingB.Stop off-loading,but keep the offshore supply vessel in the present locationC.Continue off-loading with no changesD.Move the offshore supply vessel to the downwind side

考题 If you are unable to stop a diesel engine by any other means,you should ______.A.Discharge a CO2 extinguisher in the air inletB.Pull off the distributor capC.Secure the jacket waterD.Secure the starting air supply valve

考题 Before switching on gyro-compass, you should make sure that the power supply on board is_______.A.high or lowB.AC or DCC.srong or weakD.on or off

考题 Foam extinguishes a fire by ______.A.shutting off the air supplyB.cooling the fuel to below ignition temperatureC.dispersing the fuelD.removing the source of ignition

考题 A server has been intermittently shutting off. The power going to the server was tested and is giving the appropriate voltages. Which of the following tools would be used to test the power supply?()A、 POST diagnostic cardB、 OTDRC、 TDRD、 Multimeter

考题 单选题If the overflow tank high-level alarm sounds while the fuel oil tanks are being topped off, the engineer should ().A close the static leg filling valveB close the overflow tank falling valveC reduce the fuel oil pumping rateD stop the fuel oil pumping operation

考题 单选题Before hydraulic starting of an engine on a covered lifeboat,what need NOT be checked?()A Fuel supply line valveB Pressure registered on the accumulator gaugeC Cold-spark voltage readings test lampD Engine stop control

考题 单选题In a diesel engine, offers the heat energy directly(); works as working medium and changes the heat energy to mechanical energy()A the burning of the fuel; medium shaftB fuel spray; fresh airC fuel; fuel sprayD the burning of the fuel; the burned gas mixture

考题 单选题A fuel line breaks, sprays fuel on the hot exhaust manifold, and catches fire. Your first action should be to().A Batten down the engine roomB start the fire pumpC apply carbon dioxide to the fireD shut off the fuel supply

考题 单选题For most diesel propulsion and generator engines, the over-speed trip device will stop the engine by ()A moving the governor control to stopB shutting off the lubricating oil supplyC tripping the governor emergency stop leverD shutting off the fuel supply

考题 单选题The over-speed trip installed on most diesel engine will stop the engine by shutting off the ()A water supplyB fuel oil supplyC lube oil supplyD exhaust damper

考题 单选题If a fire ignites in the engine room as a result of a high pressure fuel oil leak, you should FIRST ().A secure the ventilationB find a soda acid extinguisherC shut off the fuel oil supplyD secure the generator

考题 单选题If a tow-stroke/diesel engine is over-speeding due to leakage of lube oil into the cylinders, what should you do to stop the engine?()A Move the fuel control mechanism to the no fuel positionB Block the fuel supply by closing the master fuel valveC Shut off the fuel supply and block the flow of intake airD Relieve all pressure in the fuel system

考题 单选题When an auxiliary boiler is panting and emitting black smoke, you should ().A increase the fuel oil temperatureB decrease the fuel oil temperatureC decrease the fuel oil supply pressureD increase the air supply

考题 单选题If you are unable to stop a diesel engine by any other means,you should().A discharge a CO2 extinguisher in the air inletB pull off the distributor capC secure the jacket waterD secure the starting air supply valve

考题 单选题The fuel from the bunker tanks must be treated by before entering the service tanks(), from where the fuel enters()A centrifugal separators; the engine cylinderB oily water separators; the engine cylinderC oily water separators; the fuel supply systemD centrifuges; the fuel supply system

考题 单选题Electrically operated safety devices on auxiliary diesel engines function to stop the engine by ().A increasing the volume of intake airB shutting off the fuel supplyC increasing the engine back pressureD over-speeding the engine

考题 单选题Which one is not the normal operation for boiler shutdown?()A Carry out soot blowing if permissibleB Change fuel supply to diesel oilC Close steam stop valves on boiler when pressure is reducedD Drain boiler empty when it has cooled down

考题 单选题The flame safeguard control system of a large automatic auxiliary boiler will provide fuel shut off in the case of high ().A waterB voltageC fuel pressureD steam pressure

考题 单选题A server has been intermittently shutting off. The power going to the server was tested and is giving the appropriate voltages. Which of the following tools would be used to test the power supply?()A  POST diagnostic cardB  OTDRC  TDRD  Multimeter

考题 单选题When an engine is starting and has got a sufficiently high speed, say about 20 rpm,()A the starting air supply is cut off and fuel is injected into the cylindersB the fuel feeding is cut off and the turning gear is put inC the starting air supply is cut off and turning gear is taken outD the electric blower is shut down and fuel is injected into the cylinders

考题 单选题Before switching on gyro-compass,you should make sure that the power supply on board is().A high or lowB AC or DCC strong or weakD on or off