When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.
A.increase the fuel oil temperature
B.decrease the fuel oil temperature
C.decrease the fuel oil supply pressure
D.increase the air supply
参考答案
更多 “ When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.A.increase the fuel oil temperatureB.decrease the fuel oil temperatureC.decrease the fuel oil supply pressureD.increase the air supply ” 相关考题
考题
The correct procedure for giving an auxiliary boiler a bottom blow, is to begin .A.when the boiler has been secured long enough for most solids to settleB.when the boiler has been cooled to ambient temperatureC.only after raising the water level to within 0.5 inch of the high water cutout onlyD.after bypassing the low pressure
考题
Have you ever served the auxiliary engine to combustion heavy oil? What should be borne in mind when transferring oil; from heavy oil to light oil?
考题
what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .
考题
When issuing the duplicate database command, you use the parameter DB_FILE_NAME_CONVERT. For what purpose do you use this parameter?() A、 To indicate the location of the auxiliary-instance online redo logs.B、 To indicate the location of the target database datafiles.C、 To indicate the location of the auxiliary-instance control file and online redo logs.D、 To indicate the location of the auxiliary-instance database datafiles.E、 This is not a valid parameter when duplicating a database.
考题
单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()A
cold fuel oilB
low fuel oil pressureC
low atomizing steam pressureD
water in the fuel oil
考题
单选题When issuing the duplicate database command, you use the parameter DB_FILE_NAME_CONVERT. For what purpose do you use this parameter?()A
To indicate the location of the auxiliary-instance online redo logs.B
To indicate the location of the target database datafiles.C
To indicate the location of the auxiliary-instance control file and online redo logs.D
To indicate the location of the auxiliary-instance database datafiles.E
This is not a valid parameter when duplicating a database.
考题
单选题Black smoke coming from a boiler can be caused by ().A
low water levelB
high water levelC
excessively high fuel pressureD
low oil temperature
考题
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A
relight the boiler immediately to prevent loss of steam pressureB
relight the fire off the brickwork as the bricks are cherry redC
purge the furnace of any combustible gases before attempting to relight the fireD
speed up the feed pump to prevent dry firing when the burner flame is reestablished
考题
单选题When an auxiliary boiler is panting and emitting black smoke, you should ().A
increase the fuel oil temperatureB
decrease the fuel oil temperatureC
decrease the fuel oil supply pressureD
increase the air supply
考题
单选题High exhaust temperature and black smoke exhausting from an auxiliary diesel engine can be caused by ().A
engine overloadB
low combustion temperatureC
plugged fuel nozzle holesD
excessive compression pressure
考题
单选题The water in an auxiliary boiler should be tested daily for ().A
dissolved oxygenB
chloridesC
sludgeD
dissolved nitrogen
考题
单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()A
salinity is abnormally highB
steam demand is too highC
water level is abnormally lowD
feedwater flow is low
考题
单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A
steam demand is highB
salinity is highC
safety valve simmersD
burner flame is extinguished
考题
单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().A
air supply is shut offB
fuel supply is shut offC
water supply is shut offD
safety valve lifts
考题
单选题Exhaust pipes for separate diesel engines can be combined only when ()A
space limitations prevent separately run pipesB
the engines are small auxiliary unitsC
they are arranged to prevent gas backflow to each engineD
a waste heat boiler is installed
考题
单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.A
monkeyB
donkeyC
waste heatD
main
考题
单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()A
defective solenoid valveB
dirty fuel nozzleC
grounded high tension leadD
faulty ignition cable connector
考题
单选题The water level in a steaming auxiliary boiler will always ()A
rise when the steam pressure is increasedB
remain constant as long as the feed pump operatesC
fall when the steam pressure is decreasedD
vary as the steam demand changes
考题
单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()A
precipitate silica from solutionB
reduce corrosion in the heating coilC
prevent clogging and erosion in the coilD
maintain zero water hardness
考题
单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().A
caustic embrittlement of the boiler metalB
acidic corrosion of the boiler metalC
hard scale deposits on the boiler tubesD
etching of the heat exchange surfaces
考题
单选题Black smoke coming from a boiler can be caused by ().A
low water levelB
low oil pressureC
excessively high fuel pressureD
an improper air/fuel ratio
考题
单选题If you observe smoke coming from the turbocharger of an auxiliary diesel engine, you should()A
check the air filter for obstructionB
check for an exhaust leakC
check the exhaust temperatureD
secure the engine
考题
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A
high steam pressure in the boilerB
abnormally high feed water temperatureC
abnormally high boiler water temperatureD
steam demand exceeding feed pump capacity
考题
单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().A
check and regulate the water levelB
close the air cock once fires are litC
blowdown the gage glassD
crack the steam stop to assure protective steam flow
考题
单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A
10B
7C
4D
1
考题
单选题If an operating auxiliary boiler has a water pH reading of 7, you should ().A
bottom blow the boilerB
treat the water with caustic sodaC
treat the water with chemical scavengersD
reduce the water alkalinity to recommended readings
考题
单选题Which action should be taken when an auxiliary boiler in is operation?()A
Clean all electrical connectionsB
Lift the relief valves by handC
Inspect and clean all solenoid valvesD
Inspect for oil and water leaks