Crankcase sweating in a refrigeration system is caused by ().
A

a stuck solenoid valve

B

a shortage of refrigerant

C

too much oil in circulation

D

too much superheat


参考答案

参考解析
解析: 暂无解析
更多 “单选题Crankcase sweating in a refrigeration system is caused by ().A a stuck solenoid valveB a shortage of refrigerantC too much oil in circulationD too much superheat” 相关考题
考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().A a shortage of refrigerant in the systemB air in the systemC an accumulation of liquid refrigerant in the crankcaseD a shortage of oil in the crankcase

考题 单选题Refrigeration system compressor crankcase sweating is an indication of ().A insufficient lube oil circulating through the systemB excessive circulation of lube oil through the systemC insufficient refrigerant in the systemD an overworked compressor

考题 单选题If a refrigeration system compressor crankcase is sweating, you should ().A add refrigerant to the systemB adjust the thermal expansion valve to the proper settingC adjust the float valve to the proper holding pressureD open the hand expansion valve

考题 单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A restriction in refrigerant pipingB air and non-condensable gases in the condenserC water in the refrigerantD flooding back of liquid refrigerant from the evaporator

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().A overheated compressor bearingsB excess lube oil viscosityC carbon deposits on the compressor piston ringsD wax crystals forming in the lubricant

考题 单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().A compressorB condenserC receiverD evaporator

考题 单选题When it is necessary to open a refrigeration system for repairs and the system will be open for more than a few minutes, the open ends of the system should be ().A dehydratedB purgedC pluggedD evacuated

考题 单选题The function of () in a refrigeration plant using Freon is to move moisture from all refrigeration system.A filterB filter drierC heat exchangerD air cooler

考题 单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().A system was overcharged with refrigerantB system was low on refrigerantC suction valves were leaking slightlyD relief valve was leaking slightly

考题 单选题In a refrigeration system, foaming of the crankcase oil may cause the ().A expansion valve to overfeedB compressor to knockC water regulating valve to failD crankcase drains to plug

考题 单选题Zinc rods are installed in the refrigeration system ().A liquid strainerB liquid receiverC saltwater condenserD evaporator

考题 单选题Noise in a refrigeration compressor can be caused by ().A worn bearings and piston pinsB slugging due to flooding backC too much oil in circulationD All of the above

考题 单选题Diesel engine ‘blow-by’ into the crankcase is caused by excessive ring()A back clearanceB side clearanceC gap clearanceD taper clearance

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A refrigerant boiling out of solution from the lube oilB liquid refrigerant flooding the compressor and systemC lube oil viscosity being reduced by refrigerant dilutionD compressor suction pressure suddenly increasing

考题 单选题Refrigerant is circulated through a refrigeration system by the ().A compressorB condenserC expansion valveD evaporator

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A compressor damage from improper lubricationB refrigerant absorption by the lubricantC increased viscosity in the lubricantD carbon deposit on the compressor suction valves

考题 单选题In the () refrigeration compressor one end of the crank shaft extends through the crankcase house for connection, via a coupling or pulley, to an external drive motor.A open-typeB hermeticC semi-hermeticD all the above

考题 单选题The accumulation of air and other non-condensable gases in a refrigeration system will ().A cause a loss of the liquid sealB create a vapor lock in the liquid receiverC collect in the condenserD cause foaming of the oil in the crankcase

考题 单选题Moisture in a refrigeration system can cause ().A freezing the expansion valve closedB corrosion of system pipingC improper temperature regulationD all of the above

考题 单选题A diesel engine crankcase ventilation system ()A prevents spark generationB removes combustible gasesC determines the level of combustible gasesD provides inert gas generation in crankcase

考题 单选题Sweating of the refrigeration system compressor crankcase is caused by ().A too much superheatB insufficient superheatC suction pressure too lowD excessive refrigerant returning to the compressor

考题 单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()A Expansion valveB CondenserC EvaporatorD Compressor

考题 单选题Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.A has continuously for a long periodB suction pressure is below normalC oil level is below normalD starts after a long idle period