网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
If found oil when we open low oil level plug of separator, it indicates ()
A

the separator is overload

B

the monitor equipment of separator fails

C

the discharge pump of separator can not work

D

the temperature of oil water is low


参考答案

参考解析
解析: 暂无解析
更多 “单选题If found oil when we open low oil level plug of separator, it indicates ()A the separator is overloadB the monitor equipment of separator failsC the discharge pump of separator can not workD the temperature of oil water is low” 相关考题
考题 In the following statements about the principle of the low level controlling, which is WRONG? 0 A.Low level is monitored on the drain tank and header tank.B.If there is high differential the filters pressure across the circulatingpumps is alarmedC.The lubricating oil purifier cannot take oil from the drain tankD.If the sea water pressure falls, this also operates an alarm

考题 Overheating of the hydraulic fluid in an electro-hydraulic anchor windlass can result from a/an( ).A.overload on the pump motorB.low fluid level in the reservoirC.low fluid viscosity around the shaft sealD.high oil level in the sump

考题 If the bowl of a disk type centrifugal purifier when operated as a separator is not primed, theA.oil has a tendency to emulsify in the bowlB.purifier will act as a clarifier at the discharge ringC.oil will be lost through the water discharge portsD.oil solids will be deposited only at the intermediate top disk

考题 When the ships is going to enter into the harborA.change from heavy fuel oil to diesel oil for main engineB.pumping out bilge waterC.change sea chest form high level one to lower level oneD.test emergency generator

考题 控制面板显示EnvTem、GeaOilLev表示:()A、Gear oil lev switch、Environ temperatureB、Gear oil level、Environment temperatureC、Gear oil level switch、Environment temperatureD、Gear oil level switch、Environment temp

考题 单选题When the ship is going to enter into the harbor,()A change from heavy fuel oil to diesel oil for mail engineB pumping oil bilge waterC change sea chest form high level one to lower oneD test emergency generator

考题 单选题If oil density were greater than water’s, the oil separator ().A did workB would work wellC didnt workD wouldnt work

考题 单选题Whether using a centrifuge or a simple filter, oil cleaning and filtration will be the most effective when the oil is at a ().A high temperature and a high viscosityB high temperature and a low viscosityC low temperature and a high viscosityD low temperature and a low viscosity

考题 单选题I remember ()the oil separator the day before yesterday But it failed again.A to repairB to be repairedC repairingD being repaired

考题 单选题The vessel is out of harbor and in “Full Ahead”We are going to run fuel oil instead of () and open the fuel oil heater steam valve.A heavy oilB lube oilC fuel oilD diesel

考题 单选题The oil () in the discharging water from oil water separator exceeds 15 PPM without alarm, because the coil was burnt out.A filterB holeC pollutionD content

考题 单选题In a complete oil/water separator, more oil will separate out onto the underside of these plates and travel outwards until it is free to rise into the oil collecting space Whats the meaning of "it" in the sentence above?()A a separatorB oilC waterD an oil collecting space

考题 单选题()can cause oil flow from water outlet of a separator.A Oil inlet valve opening too quicklyB Oil temperature too highC Diameter of gravity disc too smallD Viscosity of oil too low

考题 单选题Which of the following is wrong about operation of oily water separator?()A filled with clean water before operationB keep air cushion in oil collecting space during runningC check oil level during runningD clean inner separator with low pressure stream

考题 单选题If found oil when we open low oil level plug of separator, it indicates ()A the separator is overloadB the monitor equipment of separator failsC the discharge pump of separator can not workD the temperature of oil water is low

考题 单选题When oily water separator is operating, which measure () is wrong.A pay attention to operating parametersB renew and clean separating units in timeC check oil level in separator to prevent overloadD check separating effect, if it is bad, flush with large capacity water pump

考题 单选题When finish work on the oil separator, you should()firstly.A cut off the powerB cut off the oil inletC open guide water valveD close oil outlet value

考题 单选题In an oily water separator the oil will travel () to the oil collecting spaces.A upwardsB downwardsC outwardsD forwards

考题 单选题An oil water monitor is required in order to measure ().A the oil content in waterB the water content in fuel oilC the water level in bilge wellD the oil level in bilge well

考题 单选题()can cause oil flow from sludge outlet of self cleaning separator.A Too much sludge accumulated in separator bowlB Diameter of gravity disc too largeC High level tank lack of waterD Oil input too rapidly

考题 单选题()can not cause oil flow from water outlet of self-cleaning separator.A Oil temperature too highB Diameter of gravity disc too largeC Oil temperature too lowD High level tank out of water

考题 单选题Oily water separator mis-alarms, the most possible reason is ()A separating oil too fastB the sensor flushed badlyC the discharge solenoid value out of orderD too low heating temperature

考题 单选题The time of discharging oil is short, but oily water separator discharges oil frequentlyThe possible reason is ()A the sensor of low oil level is fully covered by sludgeB the coarse strainer before the pump in suction system is cloggedC the screw pump is worn seriously and volumetric efficiency is decreasedD bilge suction value is clogged

考题 单选题Here some oil in the oily water separator, as a result of its lower (), will separate and rise into the oil collection space.A temperatureB viscosityC densityD velocity

考题 单选题The separating effect of oil separator is not very good, the reason may be()A too little seal waterB improper gravity discC oil discharging pump not working very wellD low water level of the working water

考题 单选题When separating fuel oil in oil separator, the separating quantity is() of the real quantity.A 100%B 80%C 1/2D 1/3

考题 单选题If separating effect is not good, we can improve it by ()A flushing separator with hot waterB increasing water supply flowC heat oily water properlyD opening manual oil discharge value

考题 单选题When the ships is going to enter into the harbor,().A change from diesel oil to heavy fuel oil for mail engineB pump out bilge waterC change sea chest form lower level one to high level oneD test emergency generator