单选题
In the refrigeration system, a shortage of refrigerant is indicated by ().
A

the compressor short cycling on high pressure cut out switch

B

high suction pressure

C

high head pressure

D

bubbles in the sight glass


参考答案

参考解析
解析: 暂无解析
更多 “单选题In the refrigeration system, a shortage of refrigerant is indicated by ().A the compressor short cycling on high pressure cut out switchB high suction pressureC high head pressureD bubbles in the sight glass” 相关考题
考题 Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve

考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题A refrigerant boils and vaporizes in the () in a compression refrigeration system.A liquid receiverB compressorC condenserD cooling coil

考题 单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().A a shortage of refrigerant in the systemB air in the systemC an accumulation of liquid refrigerant in the crankcaseD a shortage of oil in the crankcase

考题 单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()A Shortage of refrigerant oilB Slight shortage of refrigerantC Excessive condenser cooling water flowD Faulty expansion valve

考题 单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A restriction in refrigerant pipingB air and non-condensable gases in the condenserC water in the refrigerantD flooding back of liquid refrigerant from the evaporator

考题 单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().A compressorB condenserC receiverD evaporator

考题 单选题If a refrigeration system were short of refrigerant, the condition would result in ().A continuous running of the compressorB high suction pressureC high discharge pressureD short cycling of the compressor on the water failure switch

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().A too much refrigerant in the systemB oil entrained in the refrigerantC less than a full charge of refrigerant in the systemD ice crystals forming in the refrigerant

考题 单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().A a shortage of compressor oilB warm food in the refrigeratorC excessive condenser cooling waterD a shortage of refrigerant

考题 单选题Moisture is removed from a refrigeration system by().A bleeding refrigerant from the condenserB opening a drain petcock on the oil separatorC condensing the water in the heat exchangerD using a dehydrator cartridge

考题 单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A passing it through the expansion valveB condensing refrigerant in the system condenserC passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD maintaining a high pressure on the systems receiver

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题In which of the listed refrigeration system components does superheating of the refrigerant take place?()A Expansion valveB EvaporatorC DrierD Receiver

考题 单选题Refrigerant is circulated through a refrigeration system by the ().A compressorB condenserC expansion valveD evaporator

考题 单选题Saltwater is typically provided to a refrigeration system to ().A cool the expansion valveB prevent refrigerant superheatingC condense the refrigerant gasD prevent motor overheating

考题 单选题Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()A Sub-cooled liquidB Sub-cooled vaporC Superheated vaporD Liquid

考题 单选题Crankcase sweating in a refrigeration system is caused by ().A a stuck solenoid valveB a shortage of refrigerantC too much oil in circulationD too much superheat

考题 单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().A sub-cooled liquidB high temperature liquidC oil saturated liquidD superheated vapor

考题 单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().A liquidB dry saturated gasC wet saturated gasD superheated vapor

考题 单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some refrigerant from the system

考题 单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()A Expansion valveB CondenserC EvaporatorD Compressor