Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()
A

Sub-cooled liquid

B

Sub-cooled vapor

C

Superheated vapor

D

Liquid


参考答案

参考解析
解析: 暂无解析
更多 “单选题Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()A Sub-cooled liquidB Sub-cooled vaporC Superheated vaporD Liquid” 相关考题
考题 Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve

考题 If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

考题 Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

考题 In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

考题 If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress

考题 Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 In a chilled(冷的) water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ______.A.increasing refrigerant pressure in the coilB.increasing chilled water flow through the coolerC.sub-cooling the refrigerant in the condenserD.superheating the refrigerant in the compressor

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().A a shortage of refrigerant in the systemB air in the systemC an accumulation of liquid refrigerant in the crankcaseD a shortage of oil in the crankcase

考题 单选题If a refrigeration system compressor crankcase is sweating, you should ().A add refrigerant to the systemB adjust the thermal expansion valve to the proper settingC adjust the float valve to the proper holding pressureD open the hand expansion valve

考题 单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()A Shortage of refrigerant oilB Slight shortage of refrigerantC Excessive condenser cooling water flowD Faulty expansion valve

考题 单选题Insufficient refrigerant in a refrigeration plant may result in ().A high discharge pressureB frosting of the crankcaseC high temperature of the overboard waterD low suction pressure of compressor

考题 单选题If a refrigeration system were short of refrigerant, the condition would result in ().A continuous running of the compressorB high suction pressureC high discharge pressureD short cycling of the compressor on the water failure switch

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().A a shortage of compressor oilB warm food in the refrigeratorC excessive condenser cooling waterD a shortage of refrigerant

考题 单选题If a refrigeration compressor will not start, the reason may be ().A the pressure regulating valve is not closingB an excessive lack of refrigerant in the systemC badly leaking discharge valvesD worn piston rings

考题 单选题Before charging a refrigeration unit, the refrigerant charging lines should be()A flushed with clean refrigerant oilB purged with the refrigerantC washed with an ammonia and alcohol solutionD grounded to compressor

考题 单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A a shortage of refrigerantB the compressor running continuouslyC liquid refrigerant returning to the compressorD the compressor short cycling on the high pressure cutout

考题 单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A refrigerant boiling out of solution from the lube oilB liquid refrigerant flooding the compressor and systemC lube oil viscosity being reduced by refrigerant dilutionD compressor suction pressure suddenly increasing

考题 单选题In a chilled water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ().A increasing refrigerant pressure in the coilB increasing chilled water flow through the coolerC sub-cooling the refrigerant in the condenserD superheating the refrigerant in the compressor

考题 单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A oil foaming in the compressorB higher than normal suction and discharge pressures with a higher box temperatureC higher than normal discharge pressure with a normal box temperatureD the compressor to run continuously

考题 单选题Which of the following may cause that the compressor cuts off on high pressure cutout in a refrigeration plant? () (1) faulty condensing (2) too few refrigerant (3) high discharge pressureA any of (1) and (3)B any of (1) and (2)C any of (2) and (3)D any of (1), (2) and (3)

考题 单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().A liquidB dry saturated gasC wet saturated gasD superheated vapor

考题 单选题Sweating of the refrigeration system compressor crankcase is caused by ().A too much superheatB insufficient superheatC suction pressure too lowD excessive refrigerant returning to the compressor

考题 单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some refrigerant from the system

考题 单选题The receiver used in a refrigeration system()A stores liquid refrigerantB collects non-condensable gasesC allows refrigerant sub-coolingD prevents compressor surging