网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
When there is a flame failure in an automatically fired auxiliary boiler, the ().
A

air supply is shut off

B

fuel supply is shut off

C

water supply is shut off

D

safety valve lifts


参考答案

参考解析
解析: 暂无解析
更多 “单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().A air supply is shut offB fuel supply is shut offC water supply is shut offD safety valve lifts” 相关考题
考题 When a country runs a foreign trade deficit under a flexible foreign exchange rate system, its ______.A.imports automatically increaseB.currency automatically depreciatesC.exports automatically declineD.currency automatically appreciates

考题 If the flame from combustion in the cylinder of a four-stroke engine past the piston into the space below, the accumulation of flammable mixture would be ignited, thus resulting in _____.A.the crankcase explosionB.lifting of the cylinder safety valveC.a scavenge fireD.opening of the manhole

考题 The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished

考题 Which two statements regarding the Wireless LAN Solution Engine (WLSE) are true? ()A、 To support fault and policy reporting, the WLSE requires a Wireless Control System (WCS).B、 When WLSE detects an AP failure, it automatically increases the power and cell coverage of nearby APs.C、 WLSE requires the 2700 location appliance to offer location tracking.D、 WLSE can locate rogue APs and automatically shut them down.E、 WLSE configuration is done using the command line interface (CLI) or a WEB based template.

考题 Which two statements regarding the Wireless LAN Solution Engine (WLSE) are true?()A、To support fault and policy reporting,the WLSE requires a Wireless Control System (WCS).B、When WLSE detects an AP failure,it automatically increases the power and cell coverage of nearbyAPs.C、WLSE requires the 2700 location appliance to offer location tracking.D、WLSE can locate rogue APs and automatically shut them down.E、WLSE configuration is done using the command line interface (CLI) or a WEB based template.

考题 Which  kinds of failures make the Data Recovery Advisor (DRA) generate a manual checklist?()A、Failure when no standby database is configuredB、Failure because a data file is renamed accidentallyC、Failure that requires no archive logs to be applied for recoveryD、Failure due to loss of connectivity-for example, an unplugged disk cable

考题 Which two statements regarding the Wireless LAN Solution Engine (WLSE) are true ?()A、to support fault and policy reporting, the WLSE requires a Wireless Control System (WCS)B、when WLSE detects an AP failure, it automatically increases the power and cell coverage of nearby APsC、WLSE requires the 2700 location appliance to offer location trackingD、WLSE can locate rogue APs and automatically shut them downE、WLSE configuration is done using the command line interface (CLI) or a WEB based template

考题 Which action enables an administrator to make a VIO Server automatically activate when the physical machine is powered on?()A、Ensure the /etc/auto_start file exists on the VIOS.B、Ensure the 'cfgdev -a boot=yes' command has been executed.C、Select the 'Automatically start when the managed system is powered on' option within the VIO Server LPAR profile.D、Add the VIO Server to the 'Automatically start when the managed system is powered on' field on the Managed System properties.

考题 Which two kinds of failures make the Data Recovery Advisor (DRA) generate a manual checklist()A、failure when no standby database is configuredB、failure because a data file is renamed accidentallyC、failure that requires no archive logs to be applied for recoveryD、failure due to loss of connectivity-for example, an unplugged disk cable

考题 Which two requirements would lead towards a high availability solution?()A、When uptime is criticalB、When data must be refactoredC、When application concurrency is staticD、When data loss is unacceptableE、When application is a single point of failure

考题 单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A in the event of a flame failureB in the event of a stack fireC when the water level reach the crown sheetD when the feed pump discharge pressure drops to a preset minimum

考题 单选题Too much air in the furnace of an oil-fired boiler would be indicated by ().A yellowish flameB golden yellow flameC white flameD brilliant white flame

考题 单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A relight the boiler immediately to prevent loss of steam pressureB relight the fire off the brickwork as the bricks are cherry redC purge the furnace of any combustible gases before attempting to relight the fireD speed up the feed pump to prevent dry firing when the burner flame is reestablished

考题 单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()A water in the fuel oilB broken high tension leadsC incorrect electrode settingD full fuel pressure at the nozzle

考题 多选题Which three statements are true about database recovery operations?()ADamaged or lost data files are restored from backups.BRedo log file entries are used to roll forward the database.CUndo segments are used to roll back any uncommitted transactions.DTransactions that were active when the failure occurred are restarted.ETransactions that were active when the failure occurred are automatically committed during the recover procedure.

考题 单选题The purpose of the programmed purge cycle on an automatically fired auxiliary boiler is to()A cool the furnace to prevent pre-ignitionB remove explosive vapors from the furnaceC evaporate accumulated unburned fuel oilD provide sufficient air in the furnace to allow ignition of the fuel

考题 单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A steam demand is highB salinity is highC safety valve simmersD burner flame is extinguished

考题 单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()A excessive purging before lighting offB insufficient trail for ignition periodC a faulty transformer in the ignition circuitD insufficient purging before lighting off

考题 单选题Failure to provide _____ explanations for his frequent blunders, this young man was fired.A rationalB sentimentalC eccentricD skeptical

考题 单选题When a rocket is launched, ______ of long streams of flame and smoke can be seen.(近义分月)A dispersionB eruptionC emissionD release

考题 单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()A air or water in the furnaceB combustion pulsesC fuel oil pump failureD flame failure

考题 单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()A carbon deposits on the flame scannerB high fuel oil temperatureC low fuel oil viscosityD high steam pressure

考题 单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A a burned out solenoid in the oil supply valveB high temperature excess airC incorrectly setting the hot-well dump valveD an incorrectly positioned burner snubber realy

考题 单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()A increased fuel consumptionB increased feed water consumptionC fuel pump failureD combustion control system failure

考题 单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()A incorrect electrode settingB incorrect nozzle positionC clogged fuel nozzleD broken high tension lead

考题 单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().A check and regulate the water levelB close the air cock once fires are litC blowdown the gage glassD crack the steam stop to assure protective steam flow

考题 单选题As for a oil-fired boiler too much air would indicated by ().A yellowish flameB golden yellow flameC milky flameD brilliant white flame