网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()
A

steam demand is high

B

salinity is high

C

safety valve simmers

D

burner flame is extinguished


参考答案

参考解析
解析: 暂无解析
更多 “单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()A steam demand is highB salinity is highC safety valve simmersD burner flame is extinguished” 相关考题
考题 The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

考题 The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished

考题 When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.A.increase the fuel oil temperatureB.decrease the fuel oil temperatureC.decrease the fuel oil supply pressureD.increase the air supply

考题 单选题When lighting off an auxiliary boiler, which of the problems listed could cause the burners to sputter?()A cold fuel oilB low fuel oil pressureC low atomizing steam pressureD water in the fuel oil

考题 单选题The most common cause of scale formation in an auxiliary boiler is ()A concentrations of calcium sulfate in the boiler waterB fuel oil in the feed waterC improper treatment of the feed water with calcium sulfateD excessive feed water alkalinity

考题 单选题The purpose of the safety relief valves installed on an auxiliary boiler is to ().A relieve excess fuel oil pressure during the “off” fire cycleB admit water to the dry pipeC throttle the forced draft fan output for proper combustionD reduce excess steam pressure in the boiler

考题 单选题If a tow-stroke/diesel engine is over-speeding due to leakage of lube oil into the cylinders, what should you do to stop the engine?()A Move the fuel control mechanism to the no fuel positionB Block the fuel supply by closing the master fuel valveC Shut off the fuel supply and block the flow of intake airD Relieve all pressure in the fuel system

考题 单选题Fuel oil contamination of an auxiliary diesel engine lube oil can result in()A an increased flash pointB higher lube oil pressuresC an increased viscosityD lower lube oil pressures

考题 单选题A smoking burner with a pulsating flame in auxiliary boiler, is an indication that the()A fuel oil supply temperature is normalB burner electrode is incorrectly positionedC fuel/air ratio is incorrectD ignition current is too low

考题 单选题When an auxiliary boiler is panting and emitting black smoke, you should ().A increase the fuel oil temperatureB decrease the fuel oil temperatureC decrease the fuel oil supply pressureD increase the air supply

考题 单选题When fuel oil has seriously contaminated a diesel engine lubricating oil, you should ().A filter to remove the fuel oilB use the settler to remove the fuel oilC remove the fuel oil by centrifugingD drain and then renew the lube oil supply

考题 单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().A fuel pump failureB fan motor failureC increased feedwater consumptionD decreased boiler efficiency

考题 单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()A water in the fuel oilB broken high tension leadsC incorrect electrode settingD full fuel pressure at the nozzle

考题 单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()A salinity is abnormally highB steam demand is too highC water level is abnormally lowD feedwater flow is low

考题 单选题Which one is not the normal operation for boiler shutdown?()A Carry out soot blowing if permissibleB Change fuel supply to diesel oilC Close steam stop valves on boiler when pressure is reducedD Drain boiler empty when it has cooled down

考题 单选题The flame safeguard control system of a large automatic auxiliary boiler will provide fuel shut off in the case of high ().A waterB voltageC fuel pressureD steam pressure

考题 单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().A air supply is shut offB fuel supply is shut offC water supply is shut offD safety valve lifts

考题 单选题Thermostatic steam pressure reducing valves are used in the fuel oil service system to control the()A double bottom fuel oil tank temperatureB heater supply steam flowC pressure of the fuel supplied to the burnersD attemperator steam flow in the heater discharge circuit

考题 单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()A air or water in the furnaceB combustion pulsesC fuel oil pump failureD flame failure

考题 单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()A carbon deposits on the flame scannerB high fuel oil temperatureC low fuel oil viscosityD high steam pressure

考题 单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()A defective solenoid valveB dirty fuel nozzleC grounded high tension leadD faulty ignition cable connector

考题 单选题The fuel oil system for a diesel engine can be considered in two parts--the fuel supply and the () systems.A fuel treatmentB fuel combustionC fuel injectionD fuel separating

考题 单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A a burned out solenoid in the oil supply valveB high temperature excess airC incorrectly setting the hot-well dump valveD an incorrectly positioned burner snubber realy

考题 单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()A increased fuel consumptionB increased feed water consumptionC fuel pump failureD combustion control system failure

考题 单选题Heavy soot accumulations in an auxiliary boiler could be caused by()A water in the fuel oilB excessive cyclingC high fuel oil pressureD improper burner maintenance

考题 单选题When the incinerator is stopped, which of the following is wrong?()A After stopping supplying sludge oil, the value and pipe should be flushed by flushed by diesel oil and the incinerator continue burning for 10 minutesB Close auxiliary burner firstly and then close main burnerC After stopping fuel, restoring the position of main fuel supply valveD Stop blower as soon as stopping supplying fuel oil

考题 单选题A donkey boiler is ().A one to supply steam to the main propulsion turbineB an auxiliary boilerC A and BD neither A nor B