网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
A technician is installing a server with sixteen 1 TB drives. They want the benefit of both speed and redundancy. Which of the following RAID configurations should be used?()
A
RAID 0
B
RAID 1
C
RAID 3
D
RAID 50
参考答案
参考解析
解析:
暂无解析
更多 “单选题A technician is installing a server with sixteen 1 TB drives. They want the benefit of both speed and redundancy. Which of the following RAID configurations should be used?()A RAID 0B RAID 1C RAID 3D RAID 50” 相关考题
考题
A system administrator needs to maintain 1.2TB of storage for a database server. There are six 250GB drives available in the server for storage space. Which of the following RAID configurations would be the BEST choice given that performance and fault tolerance are important factors?()A. RAID 1 across drive pairs totaling 3 pairsB. RAID 5 across all 6 drivesC. RAID 10 across all 6 drivesD. RAID 0 across all 6 drives
考题
Which of the following RAID arrays should be used to achieve a fault tolerant array with at least 1TB of storage space? ()A、 Five 250GB drives in RAID 0B、 Six 250GB drives in RAID 5C、 Three 250GB drives in RAID 10D、 Six 250GB drives in RAID 1
考题
A customer needs 40 TB for Tier 2 Information Lifecycle Management (ILM) data installed on the System z/VM. Their current data center is critically short of floor space. Which of the following would satisfy the customer requirement()A、a DS5300 withFibre Channel drives B、an XIV with 15 modules of 1 TB drives C、a DS5100 with 2 TB SATA drivesD、an XIV with 6 modules of 1 TB drives
考题
A technician purchases a new 120 GB IDE hard disk to use in an old server as a swap drive. After adding the drive to the server, the technician discovers that the operating system does not detect the drive. After rebooting the server, the technician notices the drive is missing from POST and comes to the conclusion that the BIOS needs to be updated. The technician downloads the latest version of the BIOS update from the manufacturer website. Which action should the technician take next?()A、 backup the BIOS configuration to use laterB、 install the BIOS update from a command promptC、 create a bootable floppy and copy the BIOS update tools to the floppyD、 read the manufacturer’s guidelines and recommendations on installing the update
考题
A technician is building a Windows 2008 server and has installed a motherboard, processor, and power supply. Which of the following optical drives should the technician install?()A、Flash DriveB、DVD-RWC、CD-ROMD、SSD
考题
A technician manages a server that contains sensitive data. The server currently has two hard drives, one hosting the operating system and other generic files and the second hosting sensitive data. The technician needs to implement a technology that would guard against data loss for only the sensitive data, while adding only one additional hard drive. Which of the following should the technician implement to avoid reformatting any drives?()A、RAID 0B、RAID 1C、RAID 3D、RAID 5
考题
A system administrator needs to maintain 1.2TB of storage for a database server. There are six 250GB drives available in the server for storage space. Which of the following RAID configurations would be the BEST choice given that performance and fault tolerance are important factors?()A、RAID 1 across drive pairs totaling 3 pairsB、RAID 5 across all 6 drivesC、RAID 10 across all 6 drivesD、RAID 0 across all 6 drives
考题
A technician wants to create a spanned volume on a set of hard drives. Which of the following tools will identify if the drives will support a spanned volume?()A、System InformationB、Disk ManagementC、Device ManagerD、Task Manager
考题
Mike, a technician, is installing a wireless router for a client. Which of the following is MOST important when installing a wireless router?()A、LocationB、DCPAC、SSIDD、Number of client machines
考题
A technician is installing a new power supply into a computer. One of the power supply connectors that the technician needs to connect to the motherboard is square and contains 4-pins. This connector is known as which of the following?()A、SATAB、FDDC、IDED、ATX
考题
A technician is installing new memory in a server. The technician would consult the HCL to ensure which of the following?()A、Memory and virtual memory compatibilityB、Memory and speed compatibilityC、Memory and HDD compatibilityD、ESD standards were followed
考题
Which of the following connection types provides the BEST data bandwidth when installing thirteen external hard drives on a server?()A、USB 2.0B、SASC、SATAD、Ultra SCSI 160
考题
A technician is installing a basic router for a SOHO network. After installing the router the PCs connected to it are not able to acquire an IP address. Which of the following did the technician fail to configure correctly?()A、DHCPB、DNSC、WINSD、NAT
考题
An administrator is installing Windows Server 2003 via CD on a new server with an SAS RAID array.When the administrator reaches the option to select the target installation drive, there are no drives listed. Which of the following is the FIRST thing the administrator should do?()A、 Restart the installation via WDS.B、 Shut down the server and check that all RAID drives are connected properly.C、 Restart the installation from CD and press F6 to install RAID drivers.D、 Go into the BIOS and set all RAID drives to compatibility mode.
考题
单选题A customer needs 40 TB for Tier 2 Information Lifecycle Management (ILM) data installed on the System z/VM. Their current data center is critically short of floor space. Which of the following would satisfy the customer requirement()A
a DS5300 withFibre Channel drives B
an XIV with 15 modules of 1 TB drives C
a DS5100 with 2 TB SATA drivesD
an XIV with 6 modules of 1 TB drives
考题
单选题A customer needs approximately 24 TB of RAW storage for some media files. SATA or nearline SAS drives are the obvious choice but rack space and budget are dominating factors. Which of thefollowing choices would be the best solution for this customer?()A
N6210 with 12 2 TB SATA drives B
DS5020 with 24 1 TB SATA drives C
Storwize V7000 with 24 1 TB SATA drives D
DS3500 with 12 2 TB nearline SAS drives
考题
单选题After installing a new hard drive into a server for the purpose of mirroring the data from the first drive to the second one, the server displays an “operating system not found” error. Which of the following should the technician do to boot the server from the original drive?()A
Replace the second drive with a hot swappable one.B
Swap the drive boot order in the BIOSC
Make the second disk active under the disk management tool.D
Rebuild the array using the hardware RAID tool at boot.
考题
单选题A technician has just finished installing a new server into a server rack. Which of the following should the technician do NEXT to complete the installation documentation?()A
Update drivers, update operating system (e.g. Windows Update), create server baseline, createa new network diagram, update change management proceduresB
Create server baseline, label server, store vendor-specific documentation, update networkdiagrams, update asset tracking informationC
Create server baseline, assign server roles, install tape drive, delete network diagram, labelserver, update operating system (e.g. Windows Update)D
Install applications on server, install external drives, toss vendor-specific documentation,update network diagrams
考题
单选题A technician at a small business goes into the server room to perform maintenance on a server and notices it is very hot and audible alarms are going off. The technician is unsure of how to remedy the situation. Which of the following should the technician do?()A
Turn off all the equipment in the server closetB
Install a fan in the server closetC
Turn off the power to the server closetD
Follow escalation procedures for emergencies
考题
单选题A technician purchases a new 120 GB IDE hard disk to use in an old server as a swap drive. After adding the drive to the server, the technician discovers that the operating system does not detect the drive. After rebooting the server, the technician notices the drive is missing from POST and comes to the conclusion that the BIOS needs to be updated. The technician downloads the latest version of the BIOS update from the manufacturer website. Which action should the technician take next?()A
backup the BIOS configuration to use laterB
install the BIOS update from a command promptC
create a bootable floppy and copy the BIOS update tools to the floppyD
read the manufacturer’s guidelines and recommendations on installing the update
考题
单选题A technician is building a Windows 2008 server and has installed a motherboard, processor, and power supply. Which of the following optical drives should the technician install?()A
Flash DriveB
DVD-RWC
CD-ROMD
SSD
考题
单选题Jill, a technician, is tasked with installing BitLocker on all the machines in an office. Which of the following may the users experience?()A
Frequent rebootsB
Delayed processor timesC
Disabled Internet connectionD
Denied access to share drives
考题
单选题Which of the following RAID arrays should be used to achieve a fault tolerant array with at least 1TB of storage space? ()A
Five 250GB drives in RAID 0B
Six 250GB drives in RAID 5C
Three 250GB drives in RAID 10D
Six 250GB drives in RAID 1
考题
单选题An administrator is building a server that will run a data warehousing application.The server was ordered with eight 300GB drives.The application requires a dedicated storage location for the OS and one for critical files.The critical file storage needs fast access but must provide high redundancy.The OS requires 100GB and the file requires 950GB.Which of the following configurations will BEST suit the data warehouse needs?()A
OS:3 Drives,RAID 1 with hot spare;Files:5 Drives,RAID 5 with hot spareB
OS:2 Drives,RAID 1;Files:6 Drives,RAID 1C
OS:2 Drives,RAID 0;Files:6 Drives,RAID 5D
OS:2 Drives,RAID 1;Files:6 Drives,RAID 5 with hot spare
考题
单选题An administrator is installing Windows Server 2003 via CD on a new server with an SAS RAID array.When the administrator reaches the option to select the target installation drive, there are no drives listed. Which of the following is the FIRST thing the administrator should do?()A
Restart the installation via WDS.B
Shut down the server and check that all RAID drives are connected properly.C
Restart the installation from CD and press F6 to install RAID drivers.D
Go into the BIOS and set all RAID drives to compatibility mode.
热门标签