网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
A support specialist started to apply an APAR on a system by inserting the tape into the tape drive, and loaded the fix using smitty installp. The following error message is displayed: tape not in backup format Which of the following will resolve this problem?()
A
Change density setting to 2
B
Set tape device to /dev/rmt0
C
Set block size to 0 for variable
D
Enable compression on tape device
参考答案
参考解析
解析:
暂无解析
更多 “单选题A support specialist started to apply an APAR on a system by inserting the tape into the tape drive, and loaded the fix using smitty installp. The following error message is displayed: tape not in backup format Which of the following will resolve this problem?()A Change density setting to 2B Set tape device to /dev/rmt0C Set block size to 0 for variableD Enable compression on tape device” 相关考题
考题
A system administrator has just applied an update to an AIX system to correct a problem, The APAR number is IX49035 and was shipped as part of the PTF number U437542. After applying the APAR fix, the administrator wants to ensure that the fix is applied before informing the system users of the corrected problem. Which of the following commands should the system administrator run to verify that the APAR fix has been applied to the system?()A.lslpp -f IX49035B.lslpp -fB U437542C.instfix -f IX49035D.instfix -ik IX49035
考题
A customer wants to deploy a centralized storage system to support a new database. Which of the following factors should the storage specialist consider first?()
A. disaster recovery strategyB. the number of IOPS requiredC. the capacity of each hard driveD. how the database will be backed up
考题
The storage specialist has designed a very complex solution with the customer, and needs toverify that all associated equipment will work as expected. Which of the following is designed tohelp lower support cost and improve customer satisfaction?()A、ATScon MonitorB、Technical and Delivery AssessmentC、System Storage Interoperations CenterD、Standalone Solutions Configuration Tool
考题
What process should the storage specialist recommend to investigate IBM support for nonstandardconfigurations?()A、RFIB、RPQC、SSICD、Letter 112
考题
A customer with an IBM SAN Volume Controller attached to Windows servers calls their BusinessPartner storage specialist asking for configuration assistance. What is the appropriate response?()A、contact an IBM Customer EngineerB、send a Service Support Representative (SSR)C、recommend purchase of a Support Line contractD、engage a Field Technical Sales Support (FTSS)
考题
A system administrator has been asked to install an APAR but wants to be able to easily remove it. Which install option should be used?()A、applyB、cleanupC、commitD、reject
考题
A Business Partner storage specialist is proposing an IBM System Storage DS5000 solution to aninstalled EMC customer. Which IBM resource should the Business Partner engage to assist withcompetitive sales strategies against EMC?()A、Competeline B、Executive Briefing Center C、Competitive Benchmark Center D、Field Technical Support Specialist (FTSS)
考题
A customer asks for the thermal load (BTU/hr) to determine whether their existing cooling system will support the IBM System Storage DS8000. Where can the sales representative find this information()A、IBM System Storage DS8000: Introduction and Planning GuideB、IBM DS8000 Interoperability Matrix on the support page on the webC、IBM System Storage DS8000: User’s GuideD、IBM System Storage DS8000: Solution Assurance Guide
考题
A customer has a large UNIX environment and has engaged a pSeries technical specialist to work on a solution with them. Which of the following statements would best establish UNIX credibility with a knowledgeable customer?()A、The technical support specialist has completed a UNIX course at college.B、The technical specialist has supported several similar projects and has earned an IBM AIX certification.C、The technical support specialist’s company sells $3M of UNIX computer systems every year.D、The technical support specialist has sold and installed at least a dozen Apple and iSeries systems with POWER processors.
考题
The account executive is asking about post-sales support for a new p5 HMC. They need the pSeries technical specialist to configure an HMC with software support for the customer. Which of the following should the specialist include in the configuration?()A、SupportlineB、ServiceSuiteC、Software Maintenance Agreement (SWMA)D、Machine Control Program Remote Support Agreement (MCPRSA)
考题
The pSeries technical specialist is designing a two LPAR p5-570 with eight total processors. The system is a test system to run AIX 5.2. The customer has stated a preference for internal disks for the boot devices. The customer has said they may later need to run three or four LPARs without increasing the number of processors. What should the pSeries technical specialist tell the customer about the ability of the p5-570 to meet their requirements?()A、It will require additional SCSI adapters and I/O drawers or external disks to support more than two LPARs.B、It has sufficient built-in SCSI controllers and disk enclosures to support four total LPARs by only adding the necessary additional disks.C、It is unable to use internal disks for LPARs and therefore additional adapters I/O drawers or external disks must be used to support all LPARs.D、It can support six LPARs with internal disks but will require special features, cables and an adapter to support the additional LPARs with internal disks.
考题
A customer has asked the System x Sales Specialist to provide a solution that meets the following requirements: -- 4U rack-dense server -- 4 quad-core processors -- 32 GB of memory -- 4 Internal SAS hard drives with RAID 5 support -- Redundant Power Supplies -- 7 PCI-E slots available A competitor presented the customer with a solution comparable to a Dell PowerEdge 4-socket server. Which of the following should the System x Sales Specialist present as an advantage over the competitor’s solution? ()A、x3255B、x3655C、x3755D、x3850 M2
考题
A customer plans to order several new pSeries systems and is concerned that the additional heat load may overwhelm the current air-handling system. How might the pSeries technical specialist aid the customer in addressing their concern?()A、Direct the customer to the Installation Guide for each system to identify the power requirements.B、Direct the customer to engage their site personnel to ensure the proper power connectors are provided to support the systems.C、Direct the customer to the Site and Hardware Planning Information and review the system requirements for each new pSeries system.D、Direct the customer to the Site and Hardware Planning Information to confirm that enough space is available in the rack to allow for proper airflow.
考题
Companycom has successfully established their p5 LPAR environment on a POWER5 p5 590 running AIX 5.2. They are now ready to move to Virtual IO. What would be required to do Virtual IO?()A、Apply APAR IY62262 to the current AIX 5.2 Maintenance level 04. Virtual IO Server is not required. B、Purchase Advanced POWER Virtualization software, upgrade to AIX 5.3 maintenance level 1 and apply APAR IY60349. Virtual IO Server is not required. C、Verify that there are enough resources to add a Virtual IO Server, upgrade to AIX 5.3 with APAR IY60349, create a Virtual IO Server after applying APAR IY62262. D、Verify that there are enough resources to add a Virtual IO Server, create a Virtual IO Server and apply APAR IY62262, verify that the system is at AIX 5.2 with Maintenance level 04.
考题
A customer currently has five partitioned POWER4 systems and is adding new systems. When the pSeries technical specialist introduces the first p5 system with CoD into this environment, how should the HMC be handled?()A、Order a new HMC to support the p5 system.B、Attach the new p5 system to the existing HMC.C、Upgrade the existing HMC to accommodate both the POWER4 and p5 systems.D、Do nothing. This system does not require an HMC.
考题
A customer wants to deploy a centralized storage system to support a new database. Which of the following factors should the storage specialist consider first?()A、disaster recovery strategyB、the number of IOPS requiredC、the capacity of each hard driveD、how the database will be backed up
考题
A customer with both IBM servers and storage asked their storage specialist to present updatedinformation on the IBM storage portfolio. The specialist suspects a competitor is actively selling inthis account. Which of the following questions, if asked by the customer, would most likely indicatecompetitive activity?()A、Does the DS8700 offer virtualized arrays? B、How can the IBM SAN Volume Controller work in our environment? C、What is the raw disk capacity of the IBM System Storage DS5300? D、What are the support options available on the IBM System Storage DS5020?
考题
A system administrator has just applied an update to an AIX system to correct a problem, The APAR number is IX49035 and was shipped as part of the PTF number U437542. After applying the APAR fix, the administrator wants to ensure that the fix is applied before informing the system users of the corrected problem. Which of the following commands should the system administrator run to verify that the APAR fix has been applied to the system?()A、lslpp -f IX49035B、lslpp -fB U437542C、instfix -f IX49035D、instfix -ik IX49035
考题
单选题The pSeries technical specialist is designing a two LPAR p5-570 with eight total processors. The system is a test system to run AIX 5.2. The customer has stated a preference for internal disks for the boot devices. The customer has said they may later need to run three or four LPARs without increasing the number of processors. What should the pSeries technical specialist tell the customer about the ability of the p5-570 to meet their requirements?()A
It will require additional SCSI adapters and I/O drawers or external disks to support more than two LPARs.B
It has sufficient built-in SCSI controllers and disk enclosures to support four total LPARs by only adding the necessary additional disks.C
It is unable to use internal disks for LPARs and therefore additional adapters I/O drawers or external disks must be used to support all LPARs.D
It can support six LPARs with internal disks but will require special features, cables and an adapter to support the additional LPARs with internal disks.
考题
单选题A customer wants to deploy a centralized storage system to support a new database. Which of the following factors should the storage specialist consider first?()A
disaster recovery strategyB
the number of IOPS requiredC
the capacity of each hard driveD
how the database will be backed up
考题
单选题A system administrator has determined that a recently applied APAR needs to be removed. Which of the following installp options will remove the APAR?()A
cleanupB
commitC
deinstallD
reject
考题
单选题A System p administrator has determined that a recently applied APAR needs to be removed. Which of the following installp options will remove the APAR()A
cleanupB
uninstallC
deinstallD
reject
考题
单选题Companycom has successfully established their p5 LPAR environment on a POWER5 p5 590 running AIX 5.2. They are now ready to move to Virtual IO. What would be required to do Virtual IO?()A
Apply APAR IY62262 to the current AIX 5.2 Maintenance level 04. Virtual IO Server is not required. B
Purchase Advanced POWER Virtualization software, upgrade to AIX 5.3 maintenance level 1 and apply APAR IY60349. Virtual IO Server is not required. C
Verify that there are enough resources to add a Virtual IO Server, upgrade to AIX 5.3 with APAR IY60349, create a Virtual IO Server after applying APAR IY62262. D
Verify that there are enough resources to add a Virtual IO Server, create a Virtual IO Server and apply APAR IY62262, verify that the system is at AIX 5.2 with Maintenance level 04.
考题
单选题A customer has a large UNIX environment and has engaged a pSeries technical specialist to work on a solution with them. Which of the following statements would best establish UNIX credibility with a knowledgeable customer?()A
The technical support specialist has completed a UNIX course at college.B
The technical specialist has supported several similar projects and has earned an IBM AIX certification.C
The technical support specialist’s company sells $3M of UNIX computer systems every year.D
The technical support specialist has sold and installed at least a dozen Apple and iSeries systems with POWER processors.
考题
多选题Identify the three processes that customers can choose for patching WebLogic Server.()ADownload patches from My Oracle Support and manage them using Smart Update.BUse Enterprise Manager to download patches from My Oracle Support and apply patches to WebLogic.CDownload patches from My Oracle Support and manually modify the classpath of the application server (though it is not recommended).DDownload patches from My Oracle Support and apply them using the WebLogic Admin Console.EUse the Admin Console to connect to My Oracle Support and download patches and then target them to the domain.
热门标签
最新试卷