Which command enables new devices that are connected to the scsi5 adapter without performing a full scan of the system?()
- A、cfgmgr -f scsi5
- B、cfgmgr -i scsi5
- C、cfgmgr -t scsi5
- D、cfgmgr -l scsi5
参考答案
更多 “Which command enables new devices that are connected to the scsi5 adapter without performing a full scan of the system?()A、cfgmgr -f scsi5B、cfgmgr -i scsi5C、cfgmgr -t scsi5D、cfgmgr -l scsi5” 相关考题
考题
While configuring a new adapter using cfgmgr, an administrator receives a warning message indicating that some device packages are not installed. Additionally, the adapter displays in the Defined state.Which command will resolve the issue and make the adapter available?()A.shutdown -FrB.cfgmgr -i lpp_sourceC.mkdev -l device_nameD.mknode /dev/device_name
考题
Which cfgmgr flag will display additional information during device configuration?()
A.cfgmgr -aB.cfgmgr -vC.cfgmgr -xD.cfgmgr -o
考题
An administrator tries to change the checksum_offload setting on ent0, but the chdev command responds that the adapter is busy.What can be done to resolve this?()
A.Use chdev with -P flag and run cfgmgr.B.Use chdev with -R flag and run cfgmgr.C.Use chdev with -P flag and reboot the system.D.Use chdev with -R flag and reboot the system.
考题
Which command enables new devices that are connected to the scsi5 adapter without performing a full scan of the system?()
A.cfgmgr -f scsi5B.cfgmgr -i scsi5C.cfgmgr -t scsi5D.cfgmgr -l scsi5
考题
A system administrator notices that one of the mirrored disks, hdisk7 on datavg, has had a hardware failure. What is the best method of recover without causing additional problems?()
A.unmirrorvg datavg hdisk7 reducevg datavg hdisk7 replace the physical volume, run cfgmgr extendvg datavg hdisk7 mirrovg datavg hdisk7B.varyoffvg datavg Rmdev -l hdisk7 -d Replace the physical volu,e run cfgmgr The system will automatically remirror when the disk is replacedC.unmirrorvg datavg hdisk7 rmdev -l hdisk7 - d replace the physical volume, run cfgmgr extendvg datavg hdisk7 The system will automatically remirror when the disk is replaced.D.unmirrorvg datavg hdisk7 reducevg data hdisk7 rmdev -l hdisk7 -d replace the physical volume, run cfgmgr extendvg datavg hdisk7 mirrovg datavg
考题
A graphics card has been added and the system rebooted. When running the lsdev-Cc adapter, the graphics card is not listed in the output. Which of the following actions should be performed?()
A.Reboot system sing the mkdev -l command.B.Install device support suing the cfgmgr -i command.C.Use the SMIT console to redirect the console.D.Use SMIT devices and choose the correct adapter.
考题
A system’s backups are failing. Error log analysis indicates that there is either a hardware or media problem. Which command is used to determine if there is a hardware problem with the tape drive?()A、diagB、lscfgC、lsdevD、cfgmgr
考题
After using the alt_disk_install command to clone a system image to another disk, the system administrator noticed a large number of defined devices not allocated to the LPAR. Which of the following is the most likely cause of this situation?()A、The cfgmgr command was not run to reconfigure the devicesB、The machine was not booted into SMS MultiBoot mode after configurationC、The machine was not in full system partition mode when the volume was createdD、The alt_disk_install command was not run with the -O option to remove references in the ODM
考题
A customer has a failing HBA adapter and needs to identify the location of the adapter. Which of the following AIX commands should the specialist recommend the customer review?()A、rmdevB、chdevC、drslotD、cfgmgr
考题
While configuring a new adapter using cfgmgr, an administrator receives a warning message indicating that some device packages are not installed. Additionally, the adapter displays in the Defined state. Which command will resolve the issue and make the adapter available?()A、shutdown -FrB、cfgmgr -i lpp_sourceC、mkdev -l device_nameD、mknode /dev/device_name
考题
Which command is used by the system boot process to determine what resources are available to the system?()A、diagB、lscfgC、mpcfgD、cfgmgr
考题
Which cfgmgr flag will display additional information during device configuration?()A、cfgmgr -aB、cfgmgr -vC、cfgmgr -xD、cfgmgr -o
考题
The administrator changed the number of virtual processors from 1 to 2 in the default_profile of an LPAR. The operator ran the cfgmgr command expecting to see 2 processors after that, but did not see them. What action must be done to apply the changes?()A、Reboot AIX within the LPAR.B、Run cfgmgr against the device sys0.C、Shutdown and then activate the default_profile.D、Ensure the RSCT daemon is operative and run cfgmgr again.
考题
A graphics card has been added and the system rebooted. When running the lsdev-Cc adapter, the graphics card is not listed in the output. Which of the following actions should be performed?()A、Reboot system sing the mkdev -l command.B、Install device support suing the cfgmgr -i command.C、Use the SMIT console to redirect the console.D、Use SMIT devices and choose the correct adapter.
考题
After making changes to IP aliasing and rebooting the system, an AIX server is unable to communicate with other hosts. Which command can be run to check ent0 adapter configuration relative to IP address and network mask?()A、ifconfig -aB、errpt -aC、cfgmgr -vD、entstat -d ent0
考题
An administrator tries to change the checksum_offload setting on ent0, but the chdev command responds that the adapter is busy. What can be done to resolve this()? A、Use chdev with -P flag and run cfgmgr.B、Use chdev with -R flag and run cfgmgr.C、Use chdev with -P flag and reboot the system.D、Use chdev with -R flag and reboot the system.
考题
Users complain they cannot communicate with a server. The system administrator suspects there may be a problem with the Ethernet adapter or with the way it is configured. Which command can be run to verify the adapter is configured correctly?()A、netstat -inB、ifconfig -aC、arp -aD、cfgmgr
考题
A system administrator has been asked to document the hardware configuration of a system. Which command can be used to assist in this task?()A、lscfgB、mkdevC、lslppD、cfgmgr
考题
A new LPAR has been created that needs SAN attached disk for a database. After AIX has been installed, the fibre cables are attached to the adapters. How should the administrator configure the disks?()A、Run 'mkdev' to force the FC adapter to log into the SAN, have the SAN LUNs zoned to the server, run 'cfgmgr' to discover and configure the disks.B、Run 'mkpath' to force the FC adapter to log into the SAN, have the SAN LUNs zoned to the server, run 'cfgmgr' to discover and configure the disks.C、Run 'chpath' to force the FC adapter to log into the SAN, have the SAN LUNs zoned to the server, run 'cfgmgr' to discover and configure the disks.D、Run 'cfgmgr' to force the FC adapter to log into the SAN, have the SAN LUNs zoned to the server, run 'cfgmgr' to discover and configure the disks.
考题
A system administrator needs to replace a mirrored disk. After performing the proper removal process and replacing the disk, which of the following set of commands should be performed to bring the disk back into production?()A、 reboot, mklvcopy, syncvg B、 cfgmgr -vl ssar, chvg -va, syncvg C、 cfgmgr, extendvg, syncvg D、 extendvg, mklvcopy, syncvg
考题
A system administrator notices that one of the mirrored disks, hdisk7 on datavg, has had a hardware failure. What is the best method of recover without causing additional problems?()A、unmirrorvg datavg hdisk7 reducevg datavg hdisk7 replace the physical volume, run cfgmgr extendvg datavg hdisk7 mirrovg datavg hdisk7B、varyoffvg datavg Rmdev -l hdisk7 -d Replace the physical volu,e run cfgmgr The system will automatically remirror when the disk is replacedC、unmirrorvg datavg hdisk7 rmdev -l hdisk7 - d replace the physical volume, run cfgmgr extendvg datavg hdisk7 The system will automatically remirror when the disk is replaced.D、unmirrorvg datavg hdisk7 reducevg data hdisk7 rmdev -l hdisk7 -d replace the physical volume, run cfgmgr extendvg datavg hdisk7 mirrovg datavg
考题
While configuring a new adapter using cfgmgr, an administrator receives a warning message indicating that some device packages are not installed. Additionally, the adapter displays in the Defined state. Which command will resolve the issue and make the adapter available?() A、shutdown -FrB、cfgmgr -i C、mkdev -l D、mknode /dev/
考题
单选题While configuring a new adapter using cfgmgr, an administrator receives a warning message indicating that some device packages are not installed. Additionally, the adapter displays in the Defined state. Which command will resolve the issue and make the adapter available?()A
shutdown -FrB
cfgmgr -i C
mkdev -l D
mknode /dev/
考题
单选题After using the alt_disk_install command to clone a system image to another disk, the system administrator noticed a large number of defined devices not allocated to the LPAR. Which of the following is the most likely cause of this situation?()A
The cfgmgr command was not run to reconfigure the devicesB
The machine was not booted into SMS MultiBoot mode after configurationC
The machine was not in full system partition mode when the volume was createdD
The alt_disk_install command was not run with the -O option to remove references in the ODM
考题
单选题While configuring a new adapter using cfgmgr, an administrator receives a warning message indicating that some device packages are not installed. Additionally, the adapter displays in the Defined state. Which command will resolve the issue and make the adapter available?()A
shutdown -FrB
cfgmgr -i lpp_sourceC
mkdev -l device_nameD
mknode /dev/device_name
考题
单选题Which command enables new devices that are connected to the scsi5 adapter without performing a full scan of the system?()A
cfgmgr -f scsi5B
cfgmgr -i scsi5C
cfgmgr -t scsi5D
cfgmgr -l scsi5
考题
单选题A system administrator needs to replace a mirrored disk. After performing the proper removal process and replacing the disk, which of the following set of commands should be performed to bring the disk back into production?()A
reboot, mklvcopy, syncvg B
cfgmgr -vl ssar, chvg -va, syncvg C
cfgmgr, extendvg, syncvg D
extendvg, mklvcopy, syncvg