网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
On a Cisco Nexus 7000 Series Switch, what is the purpose of this command?() switch# config terminal switch(config)# mac address-table learning-mode conversational vlan 1-10 switch(config)#
- A、 Enable conversational learning on FabricPath vlans 1-10 for F-Series module
- B、 Enable FabricPath protocol on VLANs 1–10
- C、 No need for this command as conversational learning is enabled by default for all VLANs.
- D、 Enable conversational learning on Classical Ethernet VLAN for F-Series module
参考答案
更多 “ On a Cisco Nexus 7000 Series Switch, what is the purpose of this command?() switch# config terminal switch(config)# mac address-table learning-mode conversational vlan 1-10 switch(config)# A、 Enable conversational learning on FabricPath vlans 1-10 for F-Series moduleB、 Enable FabricPath protocol on VLANs 1–10C、 No need for this command as conversational learning is enabled by default for all VLANs.D、 Enable conversational learning on Classical Ethernet VLAN for F-Series module” 相关考题
考题
In a Cisco Unified Computing System, where are SAN port channels connected to?()A、 Only to Cisco Fibre Channel switchesB、 Only to Cisco Fibre Channel switches in NPIV modeC、 To any Fibre Channel switchD、 Directly to storage arraysE、 Only to Nexus Switches
考题
With Cisco NX-OS on a Cisco Nexus platform, which command shows memory usage, total processes, and CPU state?()A、 show memory detailedB、 show process cpu sortedC、 show system resourcesD、 show hardware capacity
考题
Which mechanism do the CNA and the Cisco Nexus 5000 Series Switches use to provide a lossless class of Ethernet traffic?()A、 LLDPB、 LACPC、 PFCD、 FIP
考题
Which Cisco product performs virtualized Ethernet switching within a VMware ESX host?()A、Nexus l000B、Nexus 2000C、Nexus 5000D、Nexus 7000
考题
Which three statements best describe multicast operation on Cisco Nexus switches in a data center?()A、 Cisco NX-OS Software does not support PIM dense mode.B、 The command ip multicast-routing must be enabled in Cisco NX-OS Software before any multicast configuration is possible on the switch.C、 PIM CLI configuration and verification commands are not available until you enable the PIM feature with the feature pim command.D、 Cisco NX-OS Software supports multicast routing per Layer 3 VRF instance.E、 The default PIM operational mode on the Cisco Nexus 7000 switch is SSM.
考题
If an enterprise customer required A switch for their branch office access layer, which family of switches would the customer likely choose from?()A、Cisco SFS 3000/7000B、Cisco Catalyst 2000 and 3000C、Cisco Catalyst 4000 and 6000D、Cisco Nexus
考题
Which attribute is used to pass the user role back to the Nexus when remote AAA is enabled?()A、 Cisco AV-pairB、 TACACS+ or RADIUS ack frame role attributeC、 DH-CHAP challenge attributeD、 privilege level attribute
考题
Which component of the Cisco nexus 1000v monitors the migration of virtual machine during vmotion events?()A、UCS MangerB、virtual supervisor moduleC、virtual ethernet moduleD、distributed virtual switch
考题
Which two statements about the Cisco Nexus 1000V VSM are true?()A、It performs switching decisions and forwarding for the VEMB、It can be run on a virtual machineC、It can be used for remote VEM switching Iine cards
考题
If A customers needed to load-balance across multiple data center. which Cisco productwould the customer consider?()A、ACE Global Site SelectorB、Site BalancerC、ISR Wide Area Acceleration ServerD、Nexus Site BalancerE、ASR Virtual Balanced Network
考题
In Cisco Nexus 1000V deployments which two statements are true?()A、Vmware provides the VNIC and driversB、Vmware provides the VNIC and Cisco provides the driversC、Cisco provides the switching and management of switchingD、Cisco provides the switching and Vmware provides the management of switching
考题
Which statement about Cisco Unified Fabric switches is correct? () A、 The Nexus 5000 family of switches does not support vPC when running in either NPV or FCoE NPV mode.B、 The MDS 9100 family of switches is an excellent design choice as a Unified Fabric edge switch. C、 The Nexus 7000 Series Switches can support the NPIV mode of operation, but cannot function as a complete Fibre Channel Forwarder.D、 The Nexus 7000 Series Switches cannot support advanced Cisco Fibre Channel features such as IVR.E、 The MDS family of Cisco Unified Fabric switches supports both the Fibre Channel Forwarder and Fibre Channel Bridge functions.
考题
he Cisco Nexus 1000V Series Switches are virtual machine access switches that are an intelligent software switch implementation for VMware vSphere environments running the Cisco NX-OS Software operating system. Together with the VMware ESX hypervisor, the Nexus 1000V supports Cisco VN-Link server virtualization technology, which provides mobile virtual machine security and network policy for VMware View components, including the DHCP snooping feature. DHCP snooping is disabled on the Nexus 1000V by default. When the DHCP snooping feature is enabled on the Nexus 1000V, what are the default trust settings for the vEthernet and uplink ports?() A、 All vEthernet ports are trusted, and all Ethernet ports such as uplinks and port channels are trusted.B、 All vEthernet ports are not trusted, and all Ethernet ports such as uplinks and port channels are not trusted.C、 All vEthernet ports are trusted and all Ethernet ports such as uplinks and port channels are not trusted.D、 All vEthernet ports are not trusted and all Ethernet ports such as uplinks and port channels are trusted.
考题
Which two Fibre Channel features are not supported in Cisco Nexus 5500 and Nexus 5000 platforms? ()A、 port securityB、 fabric bindingC、 IVRD、 port trackingE、 FICON
考题
Which Cisco product is a storage comp0nent of the Cisco data center Unified Computing Solution?()A、Nexus 1000B、UCS5 5100C、Catalyst 6500D、MDS 9000
考题
Which two statements regarding SNMP monitoring of a UCS system are correct?()A、SNMP v3 is supportedB、includes same MIBs as the Cisco Nexus7000C、does not provides MIBs downstream of the fabric interconnectD、includes same MIBs as the Cisco Nexus2000
考题
What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()A、 Cisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesB、 Cisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesC、 Two Cisco UCS 6100 Series or 6200 Series fabric interconnectsD、 Two RJ45 Ethernet cablesE、 The fabric interconnects must be in end-host mode
考题
多选题The Cisco Nexus 1000V requires which of the following VLANs to be configured:().AControlBSupervisorCPacketDManagement
考题
单选题Which option describes the default roles available to RBAC on Cisco Nexus switches?()A
admin, operator, network-admin, and network-operatorB
admin, read-only, network-admin, and network-operatorC
vdc-admin, vdc-operator, network-admin, and network-operatorD
vdc-admin, vdc-operator, network-admin, and network-operator (for Nexus 7000) and network- admin and network-operator (for other Nexus switches)E
admin and read-only
考题
单选题Which mechanism do the CNA and the Cisco Nexus 5000 Series Switches use to provide a lossless class of Ethernet traffic?()A
LLDPB
LACPC
PFCD
FIP
考题
单选题In a Cisco Unified Computing System, where are SAN port channels connected to?()A
Only to Cisco Fibre Channel switchesB
Only to Cisco Fibre Channel switches in NPIV modeC
To any Fibre Channel switchD
Directly to storage arraysE
Only to Nexus Switches
考题
多选题Which two Fibre Channel features are not supported in Cisco Nexus 5500 and Nexus 5000 platforms? ()Aport securityBfabric bindingCIVRDport trackingEFICON
考题
多选题When creating a role in a Cisco Nexus 7000 Series Switch, rules are used to define the type of operations that a role will allow the user to perform. Which two of these parameters cannot be applied as a rule? ()Aport-profileBcommandCaccess-listDfeature-groupEOID
考题
单选题With Cisco NX-OS on a Cisco Nexus platform, which command shows memory usage, total processes, and CPU state?()A
show memory detailedB
show process cpu sortedC
show system resourcesD
show hardware capacity
考题
多选题What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()ACisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesBCisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesCTwo Cisco UCS 6100 Series or 6200 Series fabric interconnectsDTwo RJ45 Ethernet cablesEThe fabric interconnects must be in end-host mode
考题
多选题Which three statements best describe multicast operation on Cisco Nexus switches in a data center?()ACisco NX-OS Software does not support PIM dense mode.BThe command ip multicast-routing must be enabled in Cisco NX-OS Software before any multicast configuration is possible on the switch.CPIM CLI configuration and verification commands are not available until you enable the PIM feature with the feature pim command.DCisco NX-OS Software supports multicast routing per Layer 3 VRF instance.EThe default PIM operational mode on the Cisco Nexus 7000 switch is SSM.
热门标签
最新试卷