Leakage of hydraulic fluid from around the shaft of a hydraulic motor may be caused by ______.

A.permanent loss of pump suction

B.worn shaft seals

C.high level in the oil sump

D.low motor RPM


参考答案

更多 “ Leakage of hydraulic fluid from around the shaft of a hydraulic motor may be caused by ______.A.permanent loss of pump suctionB.worn shaft sealsC.high level in the oil sumpD.low motor RPM ” 相关考题
考题 Overheating of the hydraulic fluid in an electro-hydraulic anchor windlass can result from a/an( ).A.overload on the pump motorB.low fluid level in the reservoirC.low fluid viscosity around the shaft sealD.high oil level in the sump

考题 If you install a new hydraulic hose in a hydraulic system, the hose must be long enough to allow for contraction to preventA.failure of the hydraulic hoseB.excessive flow through the lineC.friction in other areas of the hydraulic systemD.overheating of the hydraulic fluid

考题 Air trapped in the hydraulic fluid of a steering system may be indicated byA.the steering pumps overspeedingB.a jammed open relief valveC.a constantly occurring improper rudder responseD.excessive ram pressure

考题 Before doing any work on a hydraulic system equipped with accumulators, you shouldA.drain the accumulators and purge with oxygenB.bleed off all stored energy from the accumulators completelyC.charge the accumulators to prevent system energy lossD.pump the hydraulic fluid into the accumulators to prevent fluid loss

考题 Hydraulic machinery failures are commonly caused by contamination of the hydraulic fluid and ______.A.fluid frictionB.fluid turbulenceC.component misalignmentD.pressure surges

考题 A hydraulic motor may be driven by______.A.an electric motorB.a diesel engineC.a compressorD.oil

考题 When the steering gear is in operation, you should ______.A.check hydraulic oil levels every hourB.check the rams for overheatingC.check for excessive oil leakage from ramsD.drain water from tele-motor cylinders each watch

考题 The major cause of trouble in a mechanical-hydraulic governor is contamination of the hydraulic fluid by ______.A.dirtB.fuel oilC.governor cooling waterD.fuel oil tar(焦油)

考题 单选题If the pump for a hydraulic anchor windlass is overheating, the cause may be ().A excessive drive motor speedB excessive pump discharge pressureC too low of a tilting box angleD insufficient drive motor speed

考题 单选题A hydraulic motor may be driven by ().A an electric motorB a diesel engineC a compressorD oil

考题 单选题In the design of hydraulic piping and equipment consideration is given to minimize turbulence in the hydraulic fluid, as this will cause()A molecular fluid vibrationB energy lossesC wide pressure variationsD mechanical damage to control valves

考题 单选题The most common contaminate of governor hydraulic fluid is ().A moistureB dirtC acidD air

考题 单选题A hydraulic accumulator aboard a ship is designed to().A store fluid under pressureB act as a fluid reservoirC provide overpressure reliefD replenish fluid to a system

考题 单选题If you are given the job of adding hydraulic fluid to a mooring winch, and are not certain as to the type of fluid to use, you should ().A add fluid that is the same color as the fluid in the reservoirB add turbine oil because it is always a good substituteC add any oil that has the same viscosity as the hydraulic fluidD check the winch manufacturers instruction book

考题 单选题If a hydraulic pump is overheating, the cause may be ().A excessive internal leakage in the pumpB low discharge pressure and fluid flowC excessive fluid level in the hydraulic reservoirD operation of the pump at 100% efficiency

考题 单选题Before doing any work on a hydraulic system equipped with accumulators, you should()A drain the accumulators and purge with oxygenB bleed off all stored energy from the accumulators completelyC charge the accumulators to prevent system energy lossD pump the hydraulic fluid into the accumulators to prevent fluid loss

考题 单选题Air trapped in the hydraulic fluid of a steering system may be indicated by()A the steering pumps overspeedingB a jammed open relief valeC a constantly occurring improper rudder responseD excessive ram pressure

考题 单选题An orifice-check valve placed in a hydraulic system is used to()A regulate the fluid flow in either directionB restrict movement of hydraulic fluid in one direction, but allow free movement in the other directionC allow free movement of hydraulic fluid in both directionsD allow a restricted fluid flow in one direction only

考题 单选题The major cause of trouble in a mechanical-hydraulic governor is contamination of the hydraulic fluid by ()A dirtB fuel oilC governor cooling waterD fuel oil tars

考题 单选题Leakage of hydraulic fluid from around the shaft of a hydraulic motor may be caused by()A permanent loss of pump suctionB worn shaft sealsC high level in the oil sumpD low motor RPM

考题 单选题External and internal leakage in hydraulic systems may be caused by ().A unusual vibrationB excessive worn partsC abnormal pressureD any of the above

考题 单选题When the steering gear is in operation, you should ().A check hydraulic oil levels every hourB check the rams for overheatingC check for excessive oil leakage from ramsD drain water from telemotor cylinders each watch

考题 单选题A hydraulic accumulator is designed to().A store fluid under pressureB act as a fluid reservoirC provide overpressure reliefD replenish fluid to a system

考题 单选题Hydraulic machinery failures are commonly caused by contamination of the hydraulic fluid and ().A fluid frictionB fluid turbulenceC component misalignmentD pressure surges

考题 单选题In a shell-and-tube type hydraulic fluid cooler, the amount of heat transferred from the hydraulic fluid to the cooling water depends upon()A the temperature of the hydraulic fluidB the flow rate of the hydraulic fluidC the temperature of the cooling waterD all of the above

考题 单选题If the relief valve on the discharge side of a hydraulic pump lifts, the cause could be ().A a low load on the unitB a clogged pump suction strainerC a blockage in the line between the pump and hydraulic motorD the hydraulic motor turning too fast

考题 单选题Hydraulic machinery failures are commonly caused by misalignment of the system components and by ().A hydraulic fluid contaminationB excessive fluid frictionC turbulent fluid flowD fluid pressure surges