网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
The delivery rate of an axial-piston hydraulic pump is controlled by varying the position of the ().
A
sliding block
B
pintle
C
reaction ring
D
tilting box or swash plate
参考答案
参考解析
解析:
暂无解析
更多 “单选题The delivery rate of an axial-piston hydraulic pump is controlled by varying the position of the ().A sliding blockB pintleC reaction ringD tilting box or swash plate” 相关考题
考题
Overheating of the hydraulic fluid in an electro-hydraulic anchor windlass can result from a/an( ).A.overload on the pump motorB.low fluid level in the reservoirC.low fluid viscosity around the shaft sealD.high oil level in the sump
考题
The delivery rate of an axial piston hydraulic pump is controlled by varying the position of theA.tilting boxB.slide blockC.pintleD.reaction ring
考题
The usual number of single-acting pistons used in a variable stroke axial-piston pump isA.3 or 5B.5 or 7C.7 or 9D.9 or 11
考题
Leakage of hydraulic fluid from around the shaft of a hydraulic motor may be caused by ______.A.permanent loss of pump suctionB.worn shaft sealsC.high level in the oil sumpD.low motor RPM
考题
If one hydraulic pump of an electro-hydraulic steering unit fails, the vessel’s steering can be initially and best maintained by using the ______.A.trick wheelB.accumulatorC.standby pumpD.Telemotor
考题
单选题When the desired rudder angle is attained by a typical double mm electro-hydraulic steering gear,the().A
ram relief valves bypass oil to stop rudder movementB
six-way valve shifts to the neutral flow positionC
steering pump electric motor is de - energized by the transfer switchD
follow-up gear takes the hydraulic pump off stroke
考题
单选题If the pump for a hydraulic anchor windlass is overheating, the cause may be ().A
excessive drive motor speedB
excessive pump discharge pressureC
too low of a tilting box angleD
insufficient drive motor speed
考题
单选题The function of a centrifugal pump double volute casing is to ().A
reduce radial thrust to the impellerB
double the liquid velocity through the pump when compared to a single voluteC
reduce hydraulic end thrustD
provide the effect of multi-staging
考题
单选题Prior to running the hydraulic pump, examine the system carefully and ensure that the lever of control valves is in () position.A
neutralB
endC
openingD
closure
考题
单选题It is important with all hydraulic systems to ensure that interlocking arrangements provided for pump or motor control levers are () before the pump driving motor can be started.A
in the pert positionB
in the starboard positionC
in the neutral positionD
to be dismantled
考题
单选题If a hydraulic pump is overheating, the cause may be ().A
excessive internal leakage in the pumpB
low discharge pressure and fluid flowC
excessive fluid level in the hydraulic reservoirD
operation of the pump at 100% efficiency
考题
单选题Leakage of hydraulic fluid from around the shaft of a hydraulic motor may be caused by()A
permanent loss of pump suctionB
worn shaft sealsC
high level in the oil sumpD
low motor RPM
考题
单选题Aother name for the “swash plate” in the variable delivery pump is()A
tiltable discB
gravity discC
distributing discD
catch plate
考题
单选题When the tilting box of a variable stroke axial-piston pump is perpendicular to the pump shaft, which of the following conditions will exist?()A
The pistons reciprocateB
The ‘B’ end cylinder barrel rotatesC
There is no fluid flowD
Power is transmitted hydraulically
考题
单选题A gradual decrease in the discharge pressure of an operating hydraulic pump can be caused by ().A
the four-way control valve failing to shiftB
the bleeder valve sticking in the open positionC
cold hydraulic fluidD
a clogged air vent falter on the oil reservoir
考题
单选题The delivery rate of a variable stroke axial piston hydraulic pump is controlled by varying the position of the ().A
slide blockB
tilting boxC
pintleD
reaction ring
考题
单选题The effective pump stroke of an individual port-and-helix fuel injection pump is determined by the ()A
fuel delivery pressureB
pump plunger diameterC
plunger control rack positionD
total pump stroke
考题
单选题An axial piston, variable stroke pump is used in a vessels hydraulic steering gearUnder pressure, oil continually leaks out from between the valve plate/cylinder barrel and will().A
cause loss of hydraulic oil from the systemB
result in extreme damage to the pumpC
cause damage to the pump ff not continually drained from the pump casingD
result in the system high side pressure to substantially drop off
考题
单选题Fuel injection uses the jet pump system and a Woodward type hydraulic () is used to control engine speed.A
controllerB
governorC
instrumentD
apparatus
考题
单选题In a shell-and-tube type hydraulic fluid cooler, the amount of heat transferred from the hydraulic fluid to the cooling water depends upon()A
the temperature of the hydraulic fluidB
the flow rate of the hydraulic fluidC
the temperature of the cooling waterD
all of the above
考题
单选题If the pump for a hydraulic anchor windlass is over heating, the cause may be ().A
increased pump speedB
excessive pump discharge pressureC
too low of a tilting box angleD
low pump speed
考题
单选题As for a hydraulic vane pump, which of the following is in contact with the vanes during working: () (1)the rotor (2)the pump shaft (3)the external surface of the housingA
(1) onlyB
(2) onlyC
(1) and (2)D
(1),(2)and(3)
考题
单选题As for a hydraulic single action vane pump, the inner wall of the stator is usually of () shape.A
circularB
ellipticalC
rectangularD
hexagon
考题
单选题If one hydraulic pump of an electro-hydraulic steering unit falls, the vessels steering can be initially and best maintained by using the ().A
trick wheelB
accumulatorC
standby pumpD
telemotor
考题
单选题In an electro-hydraulic steering gear, any change in relative position between the synchronous receiver and the follow-up gear will result in()A
the pump going to full strokeB
closing of the six-way valveC
driving the rams up against the stopsD
a corresponding slowing or increasing of the pumped flow rate
考题
单选题If the relief valve on the discharge side of a hydraulic pump lifts, the cause could be ().A
a low load on the unitB
a clogged pump suction strainerC
a blockage in the line between the pump and hydraulic motorD
the hydraulic motor turning too fast
考题
单选题The usual number of single-acting pistons used in a variable stroke axial-piston pump is ().A
3 or 5B
5 or 7C
7 or 9D
9 or 11
热门标签