网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
After extinguishing a fire with CO2,it is advisable to().
A
use all CO2 available to cool the surrounding area
B
stand by with water or other agents
C
thoroughly ventilate the space of CO2
D
jettison all burning materials
参考答案
参考解析
解析:
暂无解析
更多 “单选题After extinguishing a fire with CO2,it is advisable to().A use all CO2 available to cool the surrounding areaB stand by with water or other agentsC thoroughly ventilate the space of CO2D jettison all burning materials” 相关考题
考题
Halogenated hydrocarbon, Halon in short form,is used on board ship as ________ .A.fire-extinguishing mediumB.a standard fire testC.a non-combustible materialD.a fire main
考题
Which of the following statements is FALSE,concerning the regulations pertaining to the cylinder room of a fixed CO2 fire extinguishing system ________.A.The compartment must be properly ventilatedB.The temperature of the room should never exceed 130℉C.The door must be kept unlockedD.The compartment shall be clearly marked and identifiable
考题
A fire in the galley ALWAYS poses the additional threat of ______.A.contaminating food with extinguishing agentB.spreading through the engineering spaceC.causing loss of stabilityD.a grease fire in the ventilation system
考题
A galley grease fire on the stove may be extinguished using______.A.waterB.foamC.the range hood extinguishing systemD.fire dampers
考题
After extinguishing a fire with CO2, it is advisable to ______.A.use all CO2 available to cool the surrounding areaB.stand by with water or other agentsC.thoroughly ventilate the space of CO2D.jettison all burning materials
考题
Fighting a fire in the galley poses the additional threat of ______.A.contaminating food with extinguishing agentB.spreading through the engineering spaceC.loss of stabilityD.a grease fire in the ventilation system
考题
Generally, the first action in extinguishing an LFG fire caused by escaping gas is to ______.A.sweep flames away with water sprayB.shut off the leakC.use a chemical foam fire extinguisherD.call the local fire department
考题
Deep-fat cooking equipment shall be fitted with the following:()A、An automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationB、Controls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewC、Arrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemD、an alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed
考题
单选题A class B fire is most successfully fought by().A
preventing oxygen from reaching the burning materialB
cooling the burning material below its ignition temperatureC
using the extinguishing agent to make the burning material fire-resistantD
using the extinguishing agent to absorb the heat
考题
单选题A fire in the galley always poses the additional threat of().A
contaminating food with extinguishing agentB
shutting all sources of air into the compartmentC
closing the sea chestD
a grease fire in the ventilation system
考题
单选题The basic training in fire prevention and fire fighting should include the theoretical elements which should cover ().A
the three elements of fire and explosionB
lower and upper flammable limitsC
classification of flies and applicable extinguishing agentsD
All of the above
考题
单选题Which is a disadvantage of Halon as a fire extinguishing medium?()A
Conducts electricityB
Difficult to storeC
Large volume necessary to be effectiveD
Ineffective in powdered metal fires
考题
单选题Generally, the first action in extinguishing an LFG fire caused by escaping gas is to().A
sweep flames away with water sprayB
shut off the leakC
use a chemical foam fire extinguisherD
call t e local fire department
考题
单选题Which fire extinguishing agent can NOT be used on an ethylenediamine?()A
Water foamB
Dry chemical powderC
Water fogD
Alcohol foam
考题
单选题In order to release CO2 to the machinery spaces from a fixed fire extinguishing system, you must().A
actuate an alarm and open the engine room control valveB
actuate an alarm and open the engine room CO2 releasing valveC
open the engine room control valve and shut off engine room ventilation fansD
open the engine room control valve and then the CO2 releasing valve
考题
单选题The best method of extinguishing a class A fire is to().A
remove oxygen from the areaB
cool fuel below ignition temperatureC
smother with CO2D
smother fire with foam
考题
单选题What method of extinguishing fire in a hatch is the best to minimize damages to the cargoes?().A
FoamB
CO2C
WaterD
All of the above
考题
多选题Deep-fat cooking equipment shall be fitted with the following:()AAn automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationBControls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewCArrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemDan alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed
考题
单选题What is the most important characteristic of the extinguishing agent in fighting a class C fire?()A
WeightB
TemperatureC
Electrical nonconductivityD
Cost
考题
单选题Which of the fire extinguishing agents listed is the safest to use when combating a class C fire?()A
CO2B
FoamC
Water fogD
Soda acid
考题
单选题The fire extinguishing action of CO2 comes mostly from ().A
breaking the fire chemical chain reactionB
smotheringC
coolingD
isolating the heat from the fuel
考题
单选题The best method of extinguishing a class A fire is to ().A
remove oxygen from the areaB
smother fire with foamC
smother fire with CO2D
cool fuel below ignition temperature
考题
单选题If a small fire initially breaks out in the engine room bilges, in which of the following sequences should the fire extinguishing agents or systems be used?()A
Fixed CO2,semi-portable CO2, then hand portable CO2B
Semi-portable CO2, fixedCO2, then hand portable CO2C
Hand portable, semi-portable CO2, then as a last resort the fixed CO2 systemD
Hand portable, fixed CO2, then as a last resort the semi-portable CO2
考题
单选题After extinguishing a paint locker fire using the fixed CO2 system,the next action is to have the space().A
opened and burned material removedB
left closed with vents off until all boundaries are coolC
checked for oxygen contentD
doused with water to prevent reflash
考题
单选题Generally,the first action in extinguishing an LFG fire caused by escaping gas is to().A
sweep flames away with water sprayB
shut off the leakC
use a chemical foam fire extinguisherD
call the local fire department
考题
单选题After extinguishing a fire with C02,it is availabe to().A
use all CO2 available to cool the surronding areaB
stand by with water or other agentsC
thoroughly ventilate the space of CO2D
jettison all buring materials
热门标签
最新试卷