网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
As an extinguishing agent,foam().
A
conducts electricity
B
should be directed at the base of the fire
C
is most effective on burning gases which are flowing
D
extinguishes by cooling oil fires below ignition temperature
参考答案
参考解析
解析:
暂无解析
更多 “单选题As an extinguishing agent,foam().A conducts electricityB should be directed at the base of the fireC is most effective on burning gases which are flowingD extinguishes by cooling oil fires below ignition temperature” 相关考题
考题
One of the limitations of foam as an extinguishing agent is that foam ______.A.cannot be made with salt waterB.is heavier than oil and sinks below its surfaceC.is corrosive and a hazard to fire fightersD.conducts electricity
考题
______, as the chemical extinguisher agent, should be used for an electric fire.A.dry chemical or foamB.foam or soda acidC.carbon dioxide or foamD.carbon dioxide or dry chemical
考题
An extinguishing agent which effectively cools, dilutes combustible vapors, removes oxygen, and provides a heat and smoke screen is ______.A.carbon dioxideB.Halon 1301C.dry chemicalD.water fog
考题
As an extinguishing agent, foam ______.A.conducts electricityB.should be directed at the base of the fireC.is most efffective on buring gases which are flowingD.extinguishes by cooling oil fires below ignition temperature
考题
Generally, the first action in extinguishing an LFG fire caused by escaping gas is to ______.A.sweep flames away with water sprayB.shut off the leakC.use a chemical foam fire extinguisherD.call the local fire department
考题
单选题A portable foam fire extinguisher is placed in operation by()A
turning it upside downB
pressing the foam leverC
squeezing the grip handleD
opening the hose valve
考题
单选题Production of mechanical foam by a portable in-line foam proportioner().A
increases the size of foam bubbles formedB
increases the rate of foam productionC
improves the extinguishing properties of foamD
gives the nozzleman more freedom of movement,since it can be placed anywhere in the hose line
考题
单选题Which extinguishing agent is recommended in the Chemical Data Guide for use on a carbon disulfide fire?()A
Alcohol foamB
Dry chemicalC
Chemical foamD
Water fog
考题
单选题On a bulk chemical carrier,water should NOT be used as an extinguishing agent to fight a fire if the water may come into contact with the chemical called().A
acrylic acidB
benzeneC
oleumD
vinyl toluene
考题
单选题A class B fire is most successfully fought by().A
preventing oxygen from reaching the burning materialB
cooling the burning material below its ignition temperatureC
using the extinguishing agent to make the burning material fire-resistantD
using the extinguishing agent to absorb the heat
考题
单选题What is an advantage of using foam in fire fighting?()A
It is effective in controlling fire in flowing oil such as coming from a broken fuel lineB
It absorbs heat from materials that could cause reignitionC
Most foams can be used jointly with dry chemical extinguishing agents to attack a fire by two methods of extinguishmentD
Once the surface is blanketed with foam and the fire is extinguished,no further foam is required
考题
单选题Generally, the first action in extinguishing an LFG fire caused by escaping gas is to().A
sweep flames away with water sprayB
shut off the leakC
use a chemical foam fire extinguisherD
call t e local fire department
考题
单选题Water is a very effective fire extinguishing agent because it()A
will remove all the toxic fumes from the airB
has the greatest cooling abilityC
will leave no harmful residueD
completely removes combustible vapors from the air
考题
单选题Which extinguishing agent is the best for use on electrical fires?()A
FoamB
CO2C
Dry chemicalD
Water fog
考题
单选题Which fire extinguishing agent can NOT be used on an ethylenediamine?()A
Water foamB
Dry chemical powderC
Water fogD
Alcohol foam
考题
单选题Which extinguishing agent will cool down a heated bulkhead in the least amount of time?()A
Water streamB
Water fog or aprayC
SteamD
Dry chemical
考题
单选题Which extinguishing agent is NOT recommended in the Chemical Data Guide for use on a cyclohexane fire?()A
FoamB
Carbon dioxideC
Dry chemicalD
Water fog
考题
单选题The best method of extinguishing a class A fire is to().A
remove oxygen from the areaB
cool fuel below ignition temperatureC
smother with CO2D
smother fire with foam
考题
单选题A definite advantage of using water as a fire extinguishing agent is its characteristic of().A
alternate expansion and contraction as water in a liquid state becomes a vaporB
absorption of smoke and gases as water is converted from a liquid to a vaporC
rapid contraction as water is converted from a liquid to a vaporD
rapid expansion as water absorbs heat and changes to steam
考题
单选题What is the most important characteristic of the extinguishing agent in fighting a class C fire?()A
WeightB
TemperatureC
Electrical nonconductivityD
Cost
考题
单选题Which of the following statements is true concerning Halon 1301 fire extinguishing equipment?()A
The agent is considered nontoxic at room temperature in low concentrationsB
The agent is less effective than carbon dioxideC
Halon primarily extinguishes the fire by coolingD
The agent cannot be used on electrical fires because it leaves a residue
考题
单选题Which of the following statements is true concerning carbon dioxide when used as a fire extinguishing agent?()A
Carbon dioxide is corrosive when exposed to fireB
Carbon dioxide should be applied slowly to a large engine room fireC
Its total cooling effect is far greater than waterD
Its smothering effect is excellent for class B fires
考题
多选题On what conditions may an exemption certificate,exempting from the requirement to install a fixed fire extinguishing system in a cargo space,be issued?()AThe ship is constructed and solely intended for carriage of ore, coal, grain, unseasoned timber, non-combustible cargoes or cargoes which according to the Administration constitute a low fire riskBSteel hatch covers and effective means of closing all ventilators and other openings to the cargo space are fittedCA fixed deck foam system is be fitted in lieu of the cargo space extinguishing systemDThe vessel is less than 10 000 gross tonnage
考题
单选题An extinguishing agent which effectively cools,dilutes combustible vapors,removes oxygen,and provides a heat and smoke screen is().A
carbon dioxideB
Halon 1301C
dry chemicalD
water fog
考题
单选题0ne of the limitations of foam as an extinguishing agent is that foam().A
cannot be made with salt waterB
is heavierthan oil and sinks below its surfaceC
is corrosive and to fire fightersD
conducts electricity
考题
单选题Generally,the first action in extinguishing an LFG fire caused by escaping gas is to().A
sweep flames away with water sprayB
shut off the leakC
use a chemical foam fire extinguisherD
call the local fire department
考题
单选题Where foam extinguishing systems are provided on a ship,each machinery flat in the protected space must have a(n)().A
coamingB
alarmC
drainD
fire sensor
热门标签
最新试卷