网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
An extinguishing agent which effectively cools,dilutes combustible vapors,removes oxygen,and provides a heat and smoke screen is().
A

carbon dioxide

B

Halon 1301

C

dry chemical

D

water fog


参考答案

参考解析
解析: 暂无解析
更多 “单选题An extinguishing agent which effectively cools,dilutes combustible vapors,removes oxygen,and provides a heat and smoke screen is().A carbon dioxideB Halon 1301C dry chemicalD water fog” 相关考题
考题 One of the limitations of foam as an extinguishing agent is that foam ______.A.cannot be made with salt waterB.is heavier than oil and sinks below its surfaceC.is corrosive and a hazard to fire fightersD.conducts electricity

考题 An extinguishing agent which effectively cools, dilutes combustible vapors, removes oxygen, and provides a heat and smoke screen is ______.A.carbon dioxideB.Halon 1301C.dry chemicalD.water fog

考题 As an extinguishing agent, foam ______.A.conducts electricityB.should be directed at the base of the fireC.is most efffective on buring gases which are flowingD.extinguishes by cooling oil fires below ignition temperature

考题 Foam is a very effective smothering agent and ______.A.it provides cooling as a secondary effectB.works well on extinguishing electrical firesC.can be used to combat combustible metal firesD.All of the above

考题 Which agent will be selected when the Resource Selection Criteria is set to circular routing?()A、the agent who has been in the Available state for the longest amount of time  B、the next available agent with the highest priority, as determined by the agent order in the Resources listC、the next available agent, based on the last agent selected and the agent order in the Resources list  D、the agent assigned to the selected Resource Group and is thus qualified to be selected

考题 Deep-fat cooking equipment shall be fitted with the following:()A、An automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationB、Controls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewC、Arrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemD、an alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed

考题 cindy has created a private agent. she wants her colleagues to be able to use it. which one of the following should she do to achieve this?()A、 change the agent property to shared B、 copy the agent to a domino 6 server C、 change the agent property to shared code D、 delete the agent. She must create it again as a shared agent

考题 单选题Which extinguishing agent is recommended in the Chemical Data Guide for use on a carbon disulfide fire?()A Alcohol foamB Dry chemicalC Chemical foamD Water fog

考题 单选题On a bulk chemical carrier,water should NOT be used as an extinguishing agent to fight a fire if the water may come into contact with the chemical called().A acrylic acidB benzeneC oleumD vinyl toluene

考题 单选题A class B fire is most successfully fought by().A preventing oxygen from reaching the burning materialB cooling the burning material below its ignition temperatureC using the extinguishing agent to make the burning material fire-resistantD using the extinguishing agent to absorb the heat

考题 单选题Which is a disadvantage of Halon as a fire extinguishing medium?()A Conducts electricityB Difficult to storeC Large volume necessary to be effectiveD Ineffective in powdered metal fires

考题 单选题For which of the listed classes of fire combinations would carbon dioxide be most suitable as the extinguishing agent ().A Class A and class BB Class B and class CC Class A and class CD Class C, class D, and class E

考题 单选题Which agent will be selected when the Resource Selection Criteria is set to circular routing?()A the agent who has been in the Available state for the longest amount of time  B the next available agent with the highest priority, as determined by the agent order in the Resources listC the next available agent, based on the last agent selected and the agent order in the Resources list  D the agent assigned to the selected Resource Group and is thus qualified to be selected

考题 单选题Water is a very effective fire extinguishing agent because it()A will remove all the toxic fumes from the airB has the greatest cooling abilityC will leave no harmful residueD completely removes combustible vapors from the air

考题 单选题Which extinguishing agent is best for use on a magnesium fire?()A WaterB SandC CO2D Dry chemical

考题 单选题Which extinguishing agent is the best for use on electrical fires?()A FoamB CO2C Dry chemicalD Water fog

考题 单选题As an extinguishing agent,foam().A conducts electricityB should be directed at the base of the fireC is most effective on burning gases which are flowingD extinguishes by cooling oil fires below ignition temperature

考题 单选题Which extinguishing agent will cool down a heated bulkhead in the least amount of time?()A Water streamB Water fog or aprayC SteamD Dry chemical

考题 单选题Which extinguishing agent is NOT recommended in the Chemical Data Guide for use on a cyclohexane fire?()A FoamB Carbon dioxideC Dry chemicalD Water fog

考题 多选题Deep-fat cooking equipment shall be fitted with the following:()AAn automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationBControls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewCArrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemDan alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed

考题 单选题cindy has created a private agent. she wants her colleagues to be able to use it. which one of the following should she do to achieve this?()A  change the agent property to shared B  copy the agent to a domino 6 server C  change the agent property to shared code D  delete the agent. She must create it again as a shared agent

考题 单选题What is the most important characteristic of the extinguishing agent in fighting a class C fire?()A WeightB TemperatureC Electrical nonconductivityD Cost

考题 单选题Which of the following statements is true concerning Halon 1301 fire extinguishing equipment?()A The agent is considered nontoxic at room temperature in low concentrationsB The agent is less effective than carbon dioxideC Halon primarily extinguishes the fire by coolingD The agent cannot be used on electrical fires because it leaves a residue

考题 单选题Which of the listed extinguishing agents is NOT suitable for fighting a liquid paint fire?()A Dry chemicalB FoamC WaterD Carbon dioxide

考题 单选题Which of the following statements is true concerning carbon dioxide when used as a fire extinguishing agent?()A Carbon dioxide is corrosive when exposed to fireB Carbon dioxide should be applied slowly to a large engine room fireC Its total cooling effect is far greater than waterD Its smothering effect is excellent for class B fires

考题 单选题0ne of the limitations of foam as an extinguishing agent is that foam().A cannot be made with salt waterB is heavierthan oil and sinks below its surfaceC is corrosive and to fire fightersD conducts electricity

考题 单选题Foam is a very effective smothering agent and().A it provides cooling as a secondary effectB works well on extinguishing electrical firesC can be used to combat combustible metal firesD All of the above