When does auxiliary burner of rotary nozzle incinerator begin to work? () Ⅰ.hen igniting Ⅱ.he sludge for dealing with is too much Ⅲ.efore stopping incinerator
A

Ⅰ+Ⅱ

B

Ⅰ+Ⅲ

C

Ⅱ+Ⅲ

D

Ⅰ+Ⅱ+Ⅲ


参考答案

参考解析
解析: 暂无解析
更多 “单选题When does auxiliary burner of rotary nozzle incinerator begin to work? () Ⅰ.hen igniting Ⅱ.he sludge for dealing with is too much Ⅲ.efore stopping incineratorA Ⅰ+ⅡB Ⅰ+ⅢC Ⅱ+ⅢD Ⅰ+Ⅱ+Ⅲ” 相关考题
考题 When an incinerator goes out suddenly, theosupply should be shut off quickly A.fuelB.sludgeC.airD.fuel and sludge

考题 The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished

考题 The oil sludge is burnt in the ______onboard.I’ll show you the ashes.A.boilerB.main engineC.auxiliary engineD.incinerator

考题 The oil sludge is burnt in the ______onboarA.I’ll show you the ashes.B.boilerC.main engineD.auxiliary engineE.incinerator

考题 A client asks a technician to add a DVD+R burner to a computer system. The technician does this and successfully tests the drive. Three weeks later, the client calls and says that the burner is no longer working. The technician learns that the drive reads CDs and DVDs, but will no longer burn DVDs. When arriving on site, what is the FIRST action that the technician should take?()A、check for a faulty IDE cableB、be sure that the DVD+R is formatted before using itC、check for incompatible mediaD、re-install the DVD burning software

考题 When issuing the duplicate database command, you use the parameter DB_FILE_NAME_CONVERT. For what purpose do you use this parameter?()  A、 To indicate the location of the auxiliary-instance online redo logs.B、 To indicate the location of the target database datafiles.C、 To indicate the location of the auxiliary-instance control file and online redo logs.D、 To indicate the location of the auxiliary-instance database datafiles.E、 This is not a valid parameter when duplicating a database.

考题 单选题A client asks a technician to add a DVD+R burner to a computer system. The technician does this and successfully tests the drive. Three weeks later, the client calls and says that the burner is no longer working. The technician learns that the drive reads CDs and DVDs, but will no longer burn DVDs. When arriving on site, what is the FIRST action that the technician should take?()A check for a faulty IDE cableB be sure that the DVD+R is formatted before using itC check for incompatible mediaD re-install the DVD burning software

考题 单选题The velocity of a rotary tidal current will be decreased when the Moon is().A at apogeeB newC fullD All of the above

考题 单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A in the event of a flame failureB in the event of a stack fireC when the water level reach the crown sheetD when the feed pump discharge pressure drops to a preset minimum

考题 单选题On the all-purpose nozzle,the position of the valve when the handle is all the way forward is().A shutB fogC solid streamD spray

考题 单选题The all-purpose nozzle will produce a fog spray when you().A pull the nozzle handle all the way back toward the operatorB pull the nozzle handle back to a position where the handle is perpendicular to the plane of the nozzleC push the nozzle handle forward as far as it will goD insert a fog applicator between the fire hose and nozzle

考题 单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A relight the boiler immediately to prevent loss of steam pressureB relight the fire off the brickwork as the bricks are cherry redC purge the furnace of any combustible gases before attempting to relight the fireD speed up the feed pump to prevent dry firing when the burner flame is reestablished

考题 单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().A fuel pump failureB fan motor failureC increased feedwater consumptionD decreased boiler efficiency

考题 单选题During waste clothes being charged into an incinerator, the auxiliary burner().A should be stopped manuallyB keeps the combustion as usualC would be cut off by an interlockD would replace the waste oil burner and keep going on

考题 单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()A water in the fuel oilB broken high tension leadsC incorrect electrode settingD full fuel pressure at the nozzle

考题 单选题When does auxiliary burner of incinerator put into operation? () Ⅰ. start incinerator when it is cold Ⅱ. the sludge for dealing with is little Ⅲ. the sludge for dealing with is large Ⅳ. the water and impurity in sludge are too much Ⅴ. the temperature in incinerator is low Ⅵ. dealing with little solid rubbishA Ⅰ+Ⅱ+Ⅲ+ⅤB Ⅰ+Ⅱ+Ⅲ+ⅣC Ⅰ+Ⅳ+Ⅴ+ⅥD Ⅰ+Ⅱ+Ⅲ+Ⅵ

考题 单选题When does auxiliary burner of incinerator put into operation? () Ⅰ.tart incinerator when it is cold Ⅱ.he sludge for dealing with is little Ⅲ.he sludge for dealing with is large Ⅳ.he water and impurity in sludge are too much Ⅴ.he temperature in incinerator is low Ⅵ.ealing with little solid rubbishA Ⅰ+Ⅱ+Ⅲ+ⅤB Ⅰ+Ⅱ+Ⅲ+ⅣC Ⅰ+Ⅳ+Ⅴ+ⅥD Ⅰ+Ⅱ+Ⅲ+Ⅵ

考题 单选题High exhaust temperature and black smoke exhausting from an auxiliary diesel engine can be caused by ().A engine overloadB low combustion temperatureC plugged fuel nozzle holesD excessive compression pressure

考题 单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the ().A furnace to be re-purgedB electric charge to buildup in the igniterC fuel pump to restartD drum level to stabilize

考题 单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()A defective solenoid valveB dirty fuel nozzleC grounded high tension leadD faulty ignition cable connector

考题 单选题When using a high-velocity fog stream in a passageway,the possibility of a blow back must be guarded against. Blow back is most likely to occur when().A pressure builds up in the nozzle which causes a surge of waterB the only opening in a passageway is the one from which the nozzle is being advancedC pressure in the fire hose drops below 100 psiD a bulkhead collapses due to heat and pressure

考题 单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()A a burned out solenoid in the oil supply valveB high temperature excess airC incorrectly setting the hot-well dump valveD an incorrectly positioned burner snubber realy

考题 单选题Heavy soot accumulations in an auxiliary boiler could be caused by()A water in the fuel oilB excessive cyclingC high fuel oil pressureD improper burner maintenance

考题 单选题Concerning the incinerator’s operation, which of the following is not correct?()A Scavenging time should be more 30 seconds before ignitingB The temperature of sludge tank is 80~100℃C First igniting the incinerator with diesel oil, when the temperature of health is about 600℃, the sludge oil drawn inD The ash can be dumped into sea when the distance is more than 3 miles from land

考题 单选题When the incinerator is stopped, which of the following is wrong?()A After stopping supplying sludge oil, the value and pipe should be flushed by flushed by diesel oil and the incinerator continue burning for 10 minutesB Close auxiliary burner firstly and then close main burnerC After stopping fuel, restoring the position of main fuel supply valveD Stop blower as soon as stopping supplying fuel oil

考题 单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()A incorrect electrode settingB incorrect nozzle positionC clogged fuel nozzleD broken high tension lead

考题 单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate refiring of a burner in order for the ().A furnace to be re-purgedB electric charge to buildup in the igniterC fuel pump to restartD dram level to stabilize