单选题
Excessively warm water leaving condenser may be caused by()
A
fouled tubes in shell and tube condenser
B
too little or too warm condenser water
C
air or non-condensable gas in system
D
overcharge of refrigerant
参考答案
参考解析
解析:
暂无解析
更多 “单选题Excessively warm water leaving condenser may be caused by()A fouled tubes in shell and tube condenserB too little or too warm condenser waterC air or non-condensable gas in systemD overcharge of refrigerant” 相关考题
考题
When you go shopping and want to buy some clothes,you should think about which kind of clothes you really need and decide how_____money you can _____on them. Then look at the labels that are inside the new clothes. They tell you how to _____the clothes. The label for a shirt may tell you to wash it in warm water. A sweater label may tell you to wash it in cold water. The label on a coat may say “dry clean only” and cleaning in water may _____this coat. If you do _____the directions say on the label, you can keep your clothes looking their best.1.A. muchB. manyC. large2.A. costB. spendC. take3.A. take place ofB. take use ofC. take care of4.A. changeB. replaceC. ruin5.A. asB. byC. for
考题
If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow
考题
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
考题
Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.
考题
Persons who have swallowed a non-petroleum based poison are given large quantities of warm soapy water or warm salt water to ______.A.induce vomitingB.absorb the poison from the bloodC.neutralize the poison in the bloodD.increase the digestive process and eliminate the poison
考题
What represents poor sanitary procedures ________.A.Keep and use a separate filling hose for potable(drinking)waterB.Locate potable(drinking)water tanks as low as possible in the bilgeC.Eliminate enclosed spaces in which trash,food particles,dirt may gatherD.After washing dishes with soap and warm water,sterilize them in water of at least 170℉(76.7℃)
考题
A frontal thunderstorm is caused by ______.A.pronounced local heatingB.wind being pushed up a mountainC.a warm air mass rising over a cold air massD.an increased lapse rate caused by advection of warm surface air
考题
单选题Low compressor head pressure in a refrigeration system can be caused by().A
insufficient condenser cooling waterB
excessive condenser cooling waterC
air in the refrigeration systemD
excessive refrigerant in the system
考题
单选题Black smoke coming from a boiler can be caused by ().A
low water levelB
high water levelC
excessively high fuel pressureD
low oil temperature
考题
单选题A water pump can not supply water after startingIt may be caused by ().A
closed discharge valveB
broken pipe lineC
worn shaftD
both A and B
考题
单选题In the condenser, the hot, high pressure refrigerant gas is cooled by the sea water and becomes().A
fresh waterB
vaporC
mixtureD
liquid
考题
单选题If a refrigeration compressor is short cycling on high head pressure, you should ().A
purge the condenser if the waterside is dirtyB
check for proper water flow through the condenserC
increase the high pressure cutout settingD
reduce the cooling water flow
考题
单选题If the high-pressure switch on the compressor opens and stops the compressor a possible cause could be:()A
too much cooling water going through the condenserB
not enough refrigerant in the systemC
a leak in the evaporator coilsD
no enough cooling water going through the condenser
考题
单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A
A shortage of liquid refrigerantB
Excessive frost on the evaporatorC
Excessive condenser cooling waterD
Insufficient condenser cooling water flow
考题
单选题A frontal thunderstorm is caused by().A
pronounced local heatingB
wind being pushed up a mountainC
a warm air mass rising over a cold air massD
an increased lapse rate caused by advection of warm surface air
考题
单选题If the temperature in the icebox is too high, the trouble could be()A
a clogged scale trapB
air in the systemC
automatic controls not functioning properlyD
insufficient cooling water to the condenser
考题
单选题Electrical failures in motors are caused by the breakdown of insulation, which may be caused by ()A
penetration of moistureB
accumulation of dirtC
overheatingD
All of the above
考题
单选题Fighting a rig fire in the ballast pumproom with hoses would adversely affect the stability of the rig most by().A
increasing the permeability of the pumproomB
reduction of drill water from the storage tanksC
a list caused by water filling the compartmentD
a reduced KG caused by water filling the compartment
考题
单选题In the two stage flash distilling plant, which of the pumps listed is vented to the shell of the second stage in order to remove vapor from the pump suction?()A
Condenser circulating water pumpB
Feed-water heater drain pumpC
Distillate pumpD
Air ejector condenser drain pump
考题
单选题Excessively warm water leaving condenser may be caused by()A
fouled tubes in shell and tube condenserB
too little or too warm condenser waterC
air or non-condensable gas in systemD
overcharge of refrigerant
考题
单选题In a diesel engine cooling system, the high temperature alarm contact maker will be activated on excessively high water discharge temperature from the ()A
raw water pump dischargeB
expansion tank outletC
cooling water heat exchangerD
outlet engine jacket water outlet
考题
单选题The reciprocating pump can’t draw water from a tank may be caused by ().A
leaky pipeB
opened inlet valveC
too much water in tankD
None of the above
考题
单选题Early models of the flash-type evaporators used a separate shell-and-tube heat exchanger as the air ejector condenser.More recent models use a combined air ejector condenser with the()A
distilling condenserB
salt water feed heaterC
distillate coolerD
flash chamber
考题
单选题Persons who have swallowed a non-petroleum based poison are given large quantities of warm soapy water or warm salt water to ()A
induce vomitingB
absorb the poison from the bloodC
neutralize the poison in the bloodD
increase the digestive process and eliminate the poison
考题
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A
change the expansion valve adjustmentB
readjust the water regulating valve to increase the flow of waterC
purge air from the condenserD
clean the waterside of the condenser
考题
单选题In a refrigeration system, if the cooling water to the condenser fails, the().A
box temperature solenoid valve will closeB
expansion valve will closeC
compressor will shutdownD
king valve will open
考题
单选题Which of the following may cause that excessively warm water leaves the condenser in a refrigeration plant? () (1) too little cooling water (2) too much cooling water (3) too warm cooler waterA
(1)onlyB
anyof(1),(2)and(3)C
anyof(1)and(3)D
anyof(1)and(2)
考题
单选题Which statement concerning the collection of fresh water is FALSE?()A
Fresh water may be obtained from fishB
Lifeboat covers or canopies should be washed with rain before drinking water is collectedC
Fresh water may be collected from condensation inside the liferaftD
Seawater should never be consumed
热门标签
最新试卷