网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().
A
change the expansion valve adjustment
B
readjust the water regulating valve to increase the flow of water
C
purge air from the condenser
D
clean the waterside of the condenser
参考答案
参考解析
解析:
暂无解析
更多 “单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser” 相关考题
考题
High firing pressures and low exhaust temperature in a diesel engine may resultfrom( ).A.decreased piston to cylinder head clearanceB.increased exhaust system back pressureC.early fuel injection timingD.low scavenge air temperature
考题
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
考题
In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass
考题
The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve
考题
单选题Low compressor head pressure in a refrigeration system can be caused by().A
insufficient condenser cooling waterB
excessive condenser cooling waterC
air in the refrigeration systemD
excessive refrigerant in the system
考题
单选题The refrigeration system low pressure cutout switch is actuated by ().A
an electric system managerB
a sensing bulb at the tail coil of the evaporatorC
pressure changes in the suction lineD
failure of the king solenoid valve
考题
单选题In an operating refrigeration system low on refrigerant, a liquid line sight glass will()A
be clearB
be blueC
be light greenD
show bubbles
考题
单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().A
restriction in refrigerant pipingB
air and non-condensable gases in the condenserC
water in the refrigerantD
flooding back of liquid refrigerant from the evaporator
考题
单选题In an air conditioning system, low head pressure associated with a reciprocating compressor can be the result of ()A
broken valve springsB
tight drive beltsC
high line voltageD
air in the system
考题
单选题Air entering an air-cooled refrigeration system is indicated by ().A
frosting of the liquid lineB
higher than normal head pressureC
a clear sight glassD
abnormally cold reefer boxes
考题
多选题Safe Mode is an essential Startup tool for troubleshooting Windows 98. Which two methods cause the system to start up in Safe Mode?()Astart the system in DOS Mode and run the WIN /S commandBpress the key while restarting system - select Safe ModeCstart the system in DOS Mode and run the safe.EXE fileDhold key while restarting the system; select Safe Mode
考题
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A
system is low on refrigerantB
high pressure cutout switch is improperly adjustedC
discharge valves are leaking slightlyD
discharge valves are leaking excessively
考题
单选题In the refrigeration system, a shortage of refrigerant is indicated by ().A
the compressor short cycling on high pressure cut out switchB
high suction pressureC
high head pressureD
bubbles in the sight glass
考题
单选题High firing pressures and a low exhaust temperature in a diesel engine may result from ().A
decreased piston to cylinder head clearanceB
increased exhaust system back pressureC
early fuel injection timingD
low scavenge air temperature
考题
单选题What separate the high pressure side from the low pressure side in a refrigeration system?()A
Condenser and thermal expansion valveB
King and solenoid valvesC
Compressor and thermal expansion valveD
Condenser and solenoid valve
考题
单选题Rate your level of proficiency with configuring and troubleshooting access to files and shared folders,configuring file system permissions, and troubleshooting Terminal Services. ()A
Very HighB
HighC
ModerateD
LowE
Very Low
考题
单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A
system is overcharged with refrigerantB
system is low on refrigerantC
discharge valves are leaking excessivelyD
discharge valves are leaking slightly
考题
单选题One cause of high head pressure occurring in a refrigeration system can be ().A
insufficient cooling water flow to the condenserB
a low refrigerant charge in the systemC
the liquid valve is open too muchD
high evaporator superheat
考题
单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().A
sub-cooled liquidB
high temperature liquidC
oil saturated liquidD
superheated vapor
考题
单选题The purpose of the refrigeration system low pressure cutout switch is to ()A
protect the compressor from liquid flood backB
protect the compressor from low discharge pressureC
start and stop the compressor upon system demandD
start the compressor after a drop in the evaporator pressure
考题
多选题While troubleshooting a video problem on an application server, the system administrator has determined that the video firmware should be updated. Which of the following sources should be used to locate an appropriate update for this hardware?()AThird-party manufacturerBVideo chipset manufacturerCServer manufacturerDOperating system manufacturerEShareware file sharing site
考题
单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A
in the chill boxB
before the receiverC
on the suction side of the compressorD
on the discharge side of the compressor
考题
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A
increase the amount of cooling water to the condenserB
decrease the amount of cooling water to the condenserC
add more refrigerant to the systemD
remove some refrigerant from the system
考题
单选题The low pressure side of a refrigeration system is considered to exist from the ().A
expansion valve to the compressorB
receiver to the expansion coilC
expansion valve to the evaporatorD
condenser to the expansion valve
考题
单选题If you change from a low pour point lubricant to a high pour point lubricant in a refrigeration system, ().A
compressor lubrication will be improvedB
oil will not leave the crankcaseC
compressor valves will be damagedD
oil may congeal in the evaporator
考题
单选题The presence of bubbles in a refrigeration system liquid line may ().A
promote refrigerant dehydrationB
be absorbed in the receiverC
cause low condensing pressureD
carry moisture and lead to corrosion