If the high-pressure switch on the compressor opens and stops the compressor a possible cause could be:()
A
too much cooling water going through the condenser
B
not enough refrigerant in the system
C
a leak in the evaporator coils
D
no enough cooling water going through the condenser
参考答案
参考解析
解析:
暂无解析
更多 “单选题If the high-pressure switch on the compressor opens and stops the compressor a possible cause could be:()A too much cooling water going through the condenserB not enough refrigerant in the systemC a leak in the evaporator coilsD no enough cooling water going through the condenser” 相关考题
考题
In face of the current stock market, most stock-holders_____.[A] stop injecting more money into the stock market[B] react angrily to the devaluing stock[C] switch their money around in the market[D] turn a deaf ear to the warning
考题
When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first
考题
If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch
考题
if it is cold ,you will find the air conditioner compressor stop automatically ,do you know the reasons ?
考题
The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor
考题
控制时间限设定值菜单()功能是当在一定时间内压缩机的启动次数达到该设定值时,压缩机将在一个小时内无法启动。A、STOP LAG COMPRESSOR TIMERB、FORCE START LAG COMPRESSOR TIMERC、HOT STARTS/HR COUNTERD、START LAG COMPRESSOR TIMER
考题
单选题Which will cause the high pressure cutout to stop the compressor in a R-22 system?()A
Condenser leakageB
A shortage of liquid refrigerantC
Excessive frost on the evaporatorD
Not enough condenser cooling water
考题
单选题The device used for low-pressure control and high-pressure cutout on a compressor is called a()A
cutoutB
pressure controllerC
controller switchD
cutout switch
考题
单选题The high-pressure fuel opens the fuel valve and is sprayed into the cylinder in tiny droplets known as ().A
injectionB
penetrationC
atomizationD
compression
考题
单选题The unloading system on an air compressor will ().A
increase compressor discharge pressure on demandB
increase compressor operating speed as necessaryC
allow the motor to turn the compressor opposed only by frictionD
reduce the compressor frictional load when starting
考题
单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().A
the compressor suction pressure is not too highB
all air is purged from the pump and charging fittingsC
the high pressure cutout switch is held open to prevent accidental startingD
the condenser is completely shutdown first
考题
单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().A
system was overcharged with refrigerantB
high pressure switch was improperly adjustedC
expansion valve strainers were fouledD
suction valves were leaking slightly
考题
单选题If a refrigeration system were short of refrigerant, the condition would result in ().A
continuous running of the compressorB
high suction pressureC
high discharge pressureD
short cycling of the compressor on the water failure switch
考题
单选题When the relief valve opens it discharges high pressure refrigerant vapor to the ().A
liquid strainerB
refrigerant inlet of the condenserC
inlet side of the evaporatorD
suction side of the compressor
考题
单选题If the compressor runs continually, the cause might be the()A
high-pressure cutout switch is jammed openB
low-pressure switch is jammed shutC
thermal bulb is not operating properlyD
scale trap is clogged
考题
单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A
A shortage of liquid refrigerantB
Excessive frost on the evaporatorC
Excessive condenser cooling waterD
Insufficient condenser cooling water flow
考题
单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().A
run continuouslyB
not startC
have high discharge pressureD
short cycle on the high pressure switch
考题
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().A
system is low on refrigerantB
high pressure cutout switch is improperly adjustedC
discharge valves are leaking slightlyD
discharge valves are leaking excessively
考题
单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().A
the relief valve should open before the high pressure cutoutB
the relief valve should open and allow the excess refrigerant to flow to the receiverC
the high pressure cutout switch should operate before the relief valve opensD
you should close in on the suction valve
考题
单选题If the head pressure is too high,()A
the relief valve should open before the high-pressure cutoutB
the relief valve should open and let excess refrigerant go to receiverC
the high-pressure cutout switch should operate before the relief valve opensD
close in on the suction valve
考题
单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()A
system is overcharged with refrigerantB
system is low on refrigerantC
discharge valves are leaking excessivelyD
discharge valves are leaking slightly
考题
单选题The purpose of the refrigeration system low pressure cutout switch is to ()A
protect the compressor from liquid flood backB
protect the compressor from low discharge pressureC
start and stop the compressor upon system demandD
start the compressor after a drop in the evaporator pressure
考题
单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().A
in the chill boxB
before the receiverC
on the suction side of the compressorD
on the discharge side of the compressor
考题
单选题If a compressor runs continuously, the cause might be a()A
defective thermal bulbB
clogged scale trapC
stuck high-pressure switchD
stuck low-pressure switch
考题
单选题The purpose of the low pressure cut-out switch is to ().A
maintain liquid refrigerant at the suction of the compressorB
maintain a preset suction pressure to the compressorC
start and stop the compressor at preset operating pressuresD
operate at minimum efficiency
考题
单选题Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()A
Thermal expansion valve frozen openB
Suction gas heat exchanger bypassedC
Condenser clogged or fouledD
High pressure cutout switch inoperative