网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
The boiler feed water check valves are located on the ()
A
feed pump suction line
B
hot well
C
shell of the feed heater
D
feed lines to the boiler
参考答案
参考解析
解析:
暂无解析
更多 “单选题The boiler feed water check valves are located on the ()A feed pump suction lineB hot wellC shell of the feed heaterD feed lines to the boiler” 相关考题
考题
The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler()
A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low
考题
what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .
考题
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity
考题
单选题Which of the following items is necessary for all waste heat boiler installations, regardless of design or manufacturer? ()A
Control of evaporationB
A separate means to prevent feed-water contaminationC
Power circulating pumpD
Super-heater
考题
单选题The most common cause of scale formation in an auxiliary boiler is ()A
concentrations of calcium sulfate in the boiler waterB
fuel oil in the feed waterC
improper treatment of the feed water with calcium sulfateD
excessive feed water alkalinity
考题
单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A
in the event of a flame failureB
in the event of a stack fireC
when the water level reach the crown sheetD
when the feed pump discharge pressure drops to a preset minimum
考题
单选题What is NOT a function of the steam drum of a marine water-tube boiler().A
Receives saturated steam from the generating tubesB
Serves as a reservoir of boiler feed waterC
Holds internal fittings for separation of moisture from steamD
Collects steam exhausted from the turbines
考题
单选题The purpose of the safety relief valves installed on an auxiliary boiler is to ().A
relieve excess fuel oil pressure during the “off” fire cycleB
admit water to the dry pipeC
throttle the forced draft fan output for proper combustionD
reduce excess steam pressure in the boiler
考题
单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()A
natural circulation of the water in the water tube boiler is better than that in the fire tube boilerB
for the same output the water tube boiler will carry less mass of water compared with the fire tube boilerC
the water tube boiler will cost shorter time for steam raisingD
the water tube boiler require lower skill in operating and maintaining
考题
单选题In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()A
The safety valve escape piping should be disconnected from the valve body and a blank insertedB
The boiler vent valves should be openedC
All hand-hole/manhole covers should be tightened up as much as possible to preclude any leaksD
All of the above
考题
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A
relight the boiler immediately to prevent loss of steam pressureB
relight the fire off the brickwork as the bricks are cherry redC
purge the furnace of any combustible gases before attempting to relight the fireD
speed up the feed pump to prevent dry firing when the burner flame is reestablished
考题
单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().A
operating the boiler at less than normal water levelB
installing fins on the firesides of water-tubesC
increasing the amount of excess air to the burnersD
treating the boiler water with chemical oxygen scavengers
考题
单选题In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()A
The safety valve escape piping should be disconnected from the valve body and a blank insertedB
The boiler vent valves should be openedC
All handhole/manhole covers should be tightened up as much as possible to preclude any leaksD
All of the above
考题
单选题The()enables water to be blow down or emptied from the boilerIt may be used when partially or completely emptying the boiler.A
main stem stop valveB
auxiliary steam stop valveC
feed check or control valveD
blow down valve
考题
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A
remove suspended and precipitated solids from the boiler waterB
completely drain the boiler in an emergency situationC
prevent hardened scale deposits in the water drumD
remove floating impurities from the oily water surface
考题
单选题The valve that prevents water from backing out of the boiler into the feed line is the().A
bottom-blow valveB
skin valveC
feed-check valveD
feed-stop valve
考题
单选题The second stage feed-water temperature and shell absolute pressure in a multistage, flash type, distilling plant is ()A
higher than the first stage feed-water temperature and absolute shell pressureB
lower than the first stage feed-water temperature and absolute shell pressureC
the same as the first stage feed-water temperature and absolute shell pressureD
not related to the feed-water temperature and absolute shell pressure
考题
单选题A feed pump for an auxiliary boiler might lose suction if the ().A
boiler water level is lowB
feedwater is too hotC
boiler steam demand is lowD
feedwater is too cold
考题
单选题For proper operation, auxiliary boiler feed water must have which of the following characteristics?()A
High oxygen concentrationB
Low pHC
Proper alkalinityD
All of the above
考题
单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().A
ensure feed water flow into the boilerB
keep the steam drum pressure highC
prevent water hammer in the feed lineD
help the feed water flash to steam
考题
单选题The water level in a steaming auxiliary boiler will always ()A
rise when the steam pressure is increasedB
remain constant as long as the feed pump operatesC
fall when the steam pressure is decreasedD
vary as the steam demand changes
考题
单选题Impurities from the boiler water surface can be removed through the ().A
safety valveB
blow down valveC
scum valveD
feed check valve
考题
单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()A
increased fuel consumptionB
increased feed water consumptionC
fuel pump failureD
combustion control system failure
考题
单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A
completely drain the boiler in an emergencyB
prevent sludge from forming in the drumC
remove floating impurities from the boiler water surfaceD
remove settled solids from the water drum
考题
单选题The feed water to the boiler will comprise ().A
condensateB
a small amount of make-up feedC
A and BD
None of the above
考题
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A
high steam pressure in the boilerB
abnormally high feed water temperatureC
abnormally high boiler water temperatureD
steam demand exceeding feed pump capacity
考题
单选题Which action should be taken when an auxiliary boiler in is operation?()A
Clean all electrical connectionsB
Lift the relief valves by handC
Inspect and clean all solenoid valvesD
Inspect for oil and water leaks
热门标签