网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
The boiler feed water check valves are located on the ()
A

feed pump suction line

B

hot well

C

shell of the feed heater

D

feed lines to the boiler


参考答案

参考解析
解析: 暂无解析
更多 “单选题The boiler feed water check valves are located on the ()A feed pump suction lineB hot wellC shell of the feed heaterD feed lines to the boiler” 相关考题
考题 The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low

考题 what chemicals did you use to treat the boiler water ?when you test alkalinity and acidity of water in boiler by pH test paper ? the result shows the boiler water is in acidiity . please describe what the possible cause is .

考题 If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

考题 单选题Which of the following items is necessary for all waste heat boiler installations, regardless of design or manufacturer? ()A Control of evaporationB A separate means to prevent feed-water contaminationC Power circulating pumpD Super-heater

考题 单选题The most common cause of scale formation in an auxiliary boiler is ()A concentrations of calcium sulfate in the boiler waterB fuel oil in the feed waterC improper treatment of the feed water with calcium sulfateD excessive feed water alkalinity

考题 单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()A in the event of a flame failureB in the event of a stack fireC when the water level reach the crown sheetD when the feed pump discharge pressure drops to a preset minimum

考题 单选题What is NOT a function of the steam drum of a marine water-tube boiler().A Receives saturated steam from the generating tubesB Serves as a reservoir of boiler feed waterC Holds internal fittings for separation of moisture from steamD Collects steam exhausted from the turbines

考题 单选题The purpose of the safety relief valves installed on an auxiliary boiler is to ().A relieve excess fuel oil pressure during the “off” fire cycleB admit water to the dry pipeC throttle the forced draft fan output for proper combustionD reduce excess steam pressure in the boiler

考题 单选题Which of the following statements concerning the water tube and fire tube boilers is not true?()A natural circulation of the water in the water tube boiler is better than that in the fire tube boilerB for the same output the water tube boiler will carry less mass of water compared with the fire tube boilerC the water tube boiler will cost shorter time for steam raisingD the water tube boiler require lower skill in operating and maintaining

考题 单选题In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()A The safety valve escape piping should be disconnected from the valve body and a blank insertedB The boiler vent valves should be openedC All hand-hole/manhole covers should be tightened up as much as possible to preclude any leaksD All of the above

考题 单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()A relight the boiler immediately to prevent loss of steam pressureB relight the fire off the brickwork as the bricks are cherry redC purge the furnace of any combustible gases before attempting to relight the fireD speed up the feed pump to prevent dry firing when the burner flame is reestablished

考题 单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().A operating the boiler at less than normal water levelB installing fins on the firesides of water-tubesC increasing the amount of excess air to the burnersD treating the boiler water with chemical oxygen scavengers

考题 单选题In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()A The safety valve escape piping should be disconnected from the valve body and a blank insertedB The boiler vent valves should be openedC All handhole/manhole covers should be tightened up as much as possible to preclude any leaksD All of the above

考题 单选题The()enables water to be blow down or emptied from the boilerIt may be used when partially or completely emptying the boiler.A main stem stop valveB auxiliary steam stop valveC feed check or control valveD blow down valve

考题 单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A remove suspended and precipitated solids from the boiler waterB completely drain the boiler in an emergency situationC prevent hardened scale deposits in the water drumD remove floating impurities from the oily water surface

考题 单选题The valve that prevents water from backing out of the boiler into the feed line is the().A bottom-blow valveB skin valveC feed-check valveD feed-stop valve

考题 单选题The second stage feed-water temperature and shell absolute pressure in a multistage, flash type, distilling plant is ()A higher than the first stage feed-water temperature and absolute shell pressureB lower than the first stage feed-water temperature and absolute shell pressureC the same as the first stage feed-water temperature and absolute shell pressureD not related to the feed-water temperature and absolute shell pressure

考题 单选题A feed pump for an auxiliary boiler might lose suction if the ().A boiler water level is lowB feedwater is too hotC boiler steam demand is lowD feedwater is too cold

考题 单选题For proper operation, auxiliary boiler feed water must have which of the following characteristics?()A High oxygen concentrationB Low pHC Proper alkalinityD All of the above

考题 单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().A ensure feed water flow into the boilerB keep the steam drum pressure highC prevent water hammer in the feed lineD help the feed water flash to steam

考题 单选题The water level in a steaming auxiliary boiler will always ()A rise when the steam pressure is increasedB remain constant as long as the feed pump operatesC fall when the steam pressure is decreasedD vary as the steam demand changes

考题 单选题Impurities from the boiler water surface can be removed through the ().A safety valveB blow down valveC scum valveD feed check valve

考题 单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()A increased fuel consumptionB increased feed water consumptionC fuel pump failureD combustion control system failure

考题 单选题Bottom blow valves are installed on auxiliary water-tube boilers to ()A completely drain the boiler in an emergencyB prevent sludge from forming in the drumC remove floating impurities from the boiler water surfaceD remove settled solids from the water drum

考题 单选题The feed water to the boiler will comprise ().A condensateB a small amount of make-up feedC A and BD None of the above

考题 单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().A high steam pressure in the boilerB abnormally high feed water temperatureC abnormally high boiler water temperatureD steam demand exceeding feed pump capacity

考题 单选题Which action should be taken when an auxiliary boiler in is operation?()A Clean all electrical connectionsB Lift the relief valves by handC Inspect and clean all solenoid valvesD Inspect for oil and water leaks