网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
If a refrigeration compressor is running continuously without lowering temperature as normal in the refrigerator, the trouble may be ().
A
excessive condenser cooling water
B
warm food in the refrigerator
C
a shortage of refrigerant
D
s shortage of compressor oil
参考答案
参考解析
解析:
暂无解析
更多 “单选题If a refrigeration compressor is running continuously without lowering temperature as normal in the refrigerator, the trouble may be ().A excessive condenser cooling waterB warm food in the refrigeratorC a shortage of refrigerantD s shortage of compressor oil” 相关考题
考题
If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout
考题
Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur when the compressorA.has run continuously for a long periodB.suction pressure is below normalC.oil level is below normalD.starts after a long idle period
考题
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
考题
If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch
考题
Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor
考题
Badly leaking refrigeration compressor discharge valves will cause ______.A.overfeeding of the expansion valveB.damage to the condenserC.constant running of the compressorD.flooding of the receiver
考题
If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling
考题
单选题Low compressor head pressure in a refrigeration system can be caused by().A
insufficient condenser cooling waterB
excessive condenser cooling waterC
air in the refrigeration systemD
excessive refrigerant in the system
考题
单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().A
flooding backB
superheatingC
overflowingD
recycling
考题
单选题Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().A
overheated compressor bearingsB
excess lube oil viscosityC
carbon deposits on the compressor piston ringsD
wax crystals forming in the lubricant
考题
单选题Short cycling of a refrigeration compressor refers to ().A
frequently grounding outB
frequently starting and stoppingC
running too fastD
running too slow
考题
单选题If a refrigeration system were short of refrigerant, the condition would result in ().A
continuous running of the compressorB
high suction pressureC
high discharge pressureD
short cycling of the compressor on the water failure switch
考题
单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().A
a shortage of compressor oilB
warm food in the refrigeratorC
excessive condenser cooling waterD
a shortage of refrigerant
考题
单选题Badly leaking refrigeration compressor discharge valves will cause().A
overfeeding of the expansion valveB
damage to the condenserC
constant running of the compressorD
flooding of the receiver
考题
单选题()are supplied by main switchboard directly.A
Suez Canal searchlight, air compressor and air conditioning compressorB
Air compressor, boiler blower and refrigeration plantC
Boiler blower, Suez Canal searchlight and refrigeration plantD
Suez canal searchlight, air compressor and boiler blower
考题
单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().A
always be wide open when the compressor restartsB
continue to operate as if the system were in operationC
remain open until evaporator pressure equalizes, then close until the compressor restartsD
always be completely closed until the compressor restarts
考题
单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().A
a shortage of refrigerantB
the compressor running continuouslyC
liquid refrigerant returning to the compressorD
the compressor short cycling on the high pressure cutout
考题
单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().A
refrigerant boiling out of solution from the lube oilB
liquid refrigerant flooding the compressor and systemC
lube oil viscosity being reduced by refrigerant dilutionD
compressor suction pressure suddenly increasing
考题
单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().A
refrigerant overchargeB
overfeeding by the expansion valveC
a restricted suction strainerD
due to short cycling of the compressor
考题
单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().A
oil foaming in the compressorB
higher than normal suction and discharge pressures with a higher box temperatureC
higher than normal discharge pressure with a normal box temperatureD
the compressor to run continuously
考题
单选题If the capacity of the refrigeration compressor is too large, the saturation temperature will ().A
riseB
fallC
be maintained constantD
None of the above
考题
单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().A
compressor damage from improper lubricationB
refrigerant absorption by the lubricantC
increased viscosity in the lubricantD
carbon deposit on the compressor suction valves
考题
单选题In the refrigeration compressor the temperature of the vapor is () by compression.A
raisedB
risenC
reducedD
maintained constant
考题
单选题It should be ensured that only () vapor is handled by the refrigeration compressor.A
humidityB
dryC
steamD
oil
考题
单选题The purpose of the refrigeration system low pressure cutout switch is to ()A
protect the compressor from liquid flood backB
protect the compressor from low discharge pressureC
start and stop the compressor upon system demandD
start the compressor after a drop in the evaporator pressure
考题
单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().A
liquidB
dry saturated gasC
wet saturated gasD
superheated vapor
考题
单选题Sweating of the refrigeration system compressor crankcase is caused by ().A
too much superheatB
insufficient superheatC
suction pressure too lowD
excessive refrigerant returning to the compressor
考题
单选题Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.A
has continuously for a long periodB
suction pressure is below normalC
oil level is below normalD
starts after a long idle period
热门标签