网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
The presence of air in the condenser of a refrigeration system will () the condensing pressure.
A
increase
B
reduce
C
maintain constant
D
None of the above is true
参考答案
参考解析
解析:
暂无解析
更多 “单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.A increaseB reduceC maintain constantD None of the above is true” 相关考题
考题
Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve
考题
When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first
考题
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
考题
Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.
考题
单选题Low compressor head pressure in a refrigeration system can be caused by().A
insufficient condenser cooling waterB
excessive condenser cooling waterC
air in the refrigeration systemD
excessive refrigerant in the system
考题
单选题The speed of an ocean current is dependent on().A
the density of the waterB
the air temperatureC
the presence of a high pressure area near itD
underwater soil conditions
考题
单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()A
Shortage of refrigerant oilB
Slight shortage of refrigerantC
Excessive condenser cooling water flowD
Faulty expansion valve
考题
单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().A
the compressor suction pressure is not too highB
all air is purged from the pump and charging fittingsC
the high pressure cutout switch is held open to prevent accidental startingD
the condenser is completely shutdown first
考题
单选题The heat removed from the refrigerant in the condenser of a refrigeration plant is the ()A
latent heat of expansionB
sensible heat of condensationC
heat of compressionD
all of the above
考题
单选题Air that may enter a refrigeration plant tends to collect in the ().A
upper part of the receiverB
upper part of the condenserC
down stream end of the cooling coilD
outlet end of the condenser
考题
单选题Which of the following terms represents the form of heat removed from the refrigerant in the condenser of a refrigeration system?()A
Latent heat of vaporizationB
Heat of compressionC
SuperheatD
All of the above
考题
单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A
maintain adequate coil back pressureB
prohibit flashing in the liquid lineC
reduce refrigerant volume in the systemD
reduce compressor discharge line loading
考题
单选题Air or noncondensable gas is removed from a refrigeration system by a ()A
separating chamberB
system of bafflesC
purge valveD
vacuum reducing valve
考题
单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().A
a shortage of compressor oilB
warm food in the refrigeratorC
excessive condenser cooling waterD
a shortage of refrigerant
考题
单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()A
A shortage of liquid refrigerantB
Excessive frost on the evaporatorC
Excessive condenser cooling waterD
Insufficient condenser cooling water flow
考题
单选题Air entering an air-cooled refrigeration system is indicated by ().A
frosting of the liquid lineB
higher than normal head pressureC
a clear sight glassD
abnormally cold reefer boxes
考题
单选题In the operation of a flash type evaporator equipped with air ejectors,the air and non- condensable gases are evacuated directly from the ().A
first stage flash chamberB
second stage flash chamberC
first stage after condenserD
second stage distilling condenser
考题
单选题()are supplied by main switchboard directly.A
Suez Canal searchlight, air compressor and air conditioning compressorB
Air compressor, boiler blower and refrigeration plantC
Boiler blower, Suez Canal searchlight and refrigeration plantD
Suez canal searchlight, air compressor and boiler blower
考题
单选题The purpose of the purge valve at the top of the condenser in a refrigerating system is to()A
remove any air that may accumulate in the systemB
take out unpleasant fumes from the refrigerantC
vent off excess refrigerant in an emergencyD
permit opening the refrigerating system for cleaning and inspecting
考题
单选题() is used for sensing the temperature of the room in the air condition system.A
An expansion valveB
An evaporatorC
A thermostatD
A condenser
考题
单选题Early models of the flash-type evaporators used a separate shell-and-tube heat exchanger as the air ejector condenser.More recent models use a combined air ejector condenser with the()A
distilling condenserB
salt water feed heaterC
distillate coolerD
flash chamber
考题
单选题The accumulation of air and other non-condensable gases in a refrigeration system will ().A
cause a loss of the liquid sealB
create a vapor lock in the liquid receiverC
collect in the condenserD
cause foaming of the oil in the crankcase
考题
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A
change the expansion valve adjustmentB
readjust the water regulating valve to increase the flow of waterC
purge air from the condenserD
clean the waterside of the condenser
考题
单选题In a refrigeration system, if the cooling water to the condenser fails, the().A
box temperature solenoid valve will closeB
expansion valve will closeC
compressor will shutdownD
king valve will open
考题
单选题Which of the following may cause that excessively warm water leaves the condenser in a refrigeration plant? () (1) too little cooling water (2) too much cooling water (3) too warm cooler waterA
(1)onlyB
anyof(1),(2)and(3)C
anyof(1)and(3)D
anyof(1)and(2)
考题
单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()A
The condenser and the expansion valveB
The king valve and the solenoid valveC
The compressor and the expansion valveD
The condenser and the solenoid valve
考题
单选题The presence of bubbles in a refrigeration system liquid line may ().A
promote refrigerant dehydrationB
be absorbed in the receiverC
cause low condensing pressureD
carry moisture and lead to corrosion
热门标签