网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)

Which one of these statements is true regarding hot pluggable PCIe and PCI-X slots in a Power 550?()

  • A、Cards can be added and then enabled via Hardware Management Console (HMC) GUI or command line. 
  • B、The HMC allows access to the Advanced System Management Interface (ASMI), where the slots can be managed. 
  • C、If the empty slot was already allocated to an LPAR, the LPAR can use the card after the cfgmgr script has been run. 
  • D、The Hardware Management Console (HMC) GUI can guide a customer through the process of adding a card to an empty slot. 

参考答案

更多 “Which one of these statements is true regarding hot pluggable PCIe and PCI-X slots in a Power 550?()A、Cards can be added and then enabled via Hardware Management Console (HMC) GUI or command line. B、The HMC allows access to the Advanced System Management Interface (ASMI), where the slots can be managed. C、If the empty slot was already allocated to an LPAR, the LPAR can use the card after the cfgmgr script has been run. D、The Hardware Management Console (HMC) GUI can guide a customer through the process of adding a card to an empty slot. ” 相关考题
考题 In order for DLPAR operations to be possible, the RMC daemons on the Hardware Management Console (HMC) must communicate with the RMC daemons on all of the LPARs involved. How can the RMC daemons be restarted on the HMC, causing the least disruption?()A、Run "/usr/sbin/rsct/bin/rmcctrl z" as hscroot. B、Reboot the HMC, either through the GUI or via the command line. C、Disable and re-enable RMC in the Firewall settings in the HMC GUI. D、Select the "Partition Communication" checkbox in the LAN Adapter dialogue box.

考题 A customer has 4 POWER6 servers managed by a Hardware Management Console (HMC). They plan to install a second HMC for redundancy.  Which of the following statements correctlydescribes the dual HMC environment? ()A、 To provide the Service Agent function, both HMCs must have Service Agent enabled and a dedicated modem and phone line.B、 Authorized users must have the same username and password on both HMCs, so that every user of one HMC is automatically authorized on the other.C、 Both HMCs are automatically notified of any changes that occur in the managed systems, so results of changes made to the managed system by one HMC are visible on theD、 Both HMCs must be running the same software revision. Software maintenance must be performed on both HMCs at the same time, but one HMC should be disconnected from

考题 A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

考题 An administrator wants to query the CPU resources of the managed system 9117-MMA*6512345 from the Hardware Management Console (HMC) command line.  Which of the following HMC commands could achieve this?()A、 lssysres -r cpu -m 9117-MMA*6512345 -r sysB、 lssyscfg -r proc -m 9117-MMA*6512345 -r sysC、 lshwres -r proc -m 9117-MMA*6512345 --level sysD、 lshwcfg -r proc -m 9117-MMA*6512345 --level sys

考题 Which of the following can deploy system plans generated by the IBM System Planning Tool (SPT)?()A、 The Hardware Management Console (HMC) and Integrated Virtualization Manager (IVM).B、 The Hardware Management Console (HMC) and Advanced System Manager Interface (ASMI).C、 Integrated Virtualization Manager (IVM) and Advanced System Manager Interface (ASMI).D、 Integrated Virtualization Manager (IVM) and BladeCenter Advanced Management Module (AMM).

考题 Prior to implementing an LPAR system, which of the following needs to be done?()A、A graphics monitor must be attached to the serverB、Cluster System Management (CSM) software must be installedC、The LPAR system must have an Hardware Management Console (HMC) connectedD、Each LPAR must be configured with a CDROM for operating system installation

考题 An administrator needs to recover an HMC due to a failed disk. The disk has been replaced, allowing the administrator to reinstall the HMC back to the required release of software. Backups of both the HMC Console Data and Upgrade Data are available. After reloading the HMC with the Recovery DVDs, what are the next steps to restore the HMC configuration?()A、Use the 'HMC Management Restore HMC Data' option to first restore just the HMC Data..B、Use the 'HMC Management Restore Upgrade Data' option to first restore just the Upgrade Data.C、Use the 'HMC Management Restore HMC Data' option to first restore the HMC Data and then the Upgrade Data.D、Use the 'HMC Management Restore Upgrade Data' option to first restore the Upgrade Data, and then the HMC Data.

考题 What does the "allow performance information collection" button do in the Hardware Management Console (HMC) GUI? ()A、 It allows you to get inter partition reports, or cross partition performance activity.B、 It will allow IBM remote technical support to get performance information from the machine.C、 It is effective only on POWER6 and when Live Partition Mobility operations are planned.D、 It will start standard performance monitoring tools when an LPAR boots up, the output will be saved to the /etc/perf directory by default.

考题 Which of the following statements is true regarding implementing Live Partition Mobility on two existing POWER6 based systems?()A、The systems must use internal storage for boot purposes. B、All virtualized ethernet adapters must be numbered below 10. C、The mobile partition's network and disk access must be virtualized. D、Each system must be controlled by a different Hardware Management Console (HMC). 

考题 After purchasing the Active Memory Expansion (AME) Enablement Feature,what tasks must be completed before AME can be used?()A、Enable using active partition properties with DLPARB、Enter the activation key via the AIX 6.1 command line and reboot AIXC、Enter the activation key via the HMC,power cycle the managed system and start the LPARD、Enter the activation key via the HMC,modify the partition profile and restart the LPAR

考题 A customer plans to consolidate several systems onto POWER7. Their immediate requirement is to have a single Power 770, and they will buy a second Power 770 at a later stage. They want to keep their existing three POWER5 570s and three POWER6 520s which are all managed by an HMC (7310-CR3). Which of these statements is true and would minimize the cost?()A、All the machines can be connected to the existing HMC, as long as it is updated to code level 7.7.1 or laterB、The Power 770 requires an HMC (7042-CR5 or later), so they must buy one. All of the systems can be managed by this new HMCC、They should buy a new HMC for the Power 770 system, and leave the POWER5 and POWER6 based systems connected to the existing oneD、The Power 770 requires an HMC, so they should connect the Power 770 to the HMC and convert the POWER5 and POWER6 based servers to IVM

考题 An administrator is looking for the "Open Restricted Shell Terminal" option on the HMC GUI. Under which panel is this option available?() A、HMC Management, but only from a local connectionB、Service Management, but only from a local connection.C、Systems Management, but only from a local connection.D、Systems Management, but only from a remote connection.

考题 Which of the following interfaces is required to implement Workload Partition Mobility? ()A、 Workload Partitions Manager for AIXB、 Hardware Management Console (HMC) GUIC、 Integrated Virtualization Manager (IVM)D、 Advanced System Management Interface (ASMI)

考题 On which HMC GUI panel can the ’Enable Electronic Service Agent’ option be found?() A、HMC ManagementB、Systems ManagementC、Service ManagementD、Electronic Management

考题 Which of the following is a feature of Integrated Virtualization Manager (IVM)? ()A、 It has a GUI interface for upgrading system firmware. B、 It creates and manages AIX/Linux and VIOS type LPARs. C、 It can be managed by the Hardware Management Console (HMC). D、 It supports Live Partition Mobility on POWER6 systems and above.

考题 An administrator is looking for the "Open RestrictedShell Terminal" option on the HMC GUI. Under which panel is this option available?()A、HMC Management, but only from a local connection.B、Service Management, but only from a local connection.C、Systems Management, but only from a local connection.D、Systems Management, but only from a remote connection.

考题 单选题Prior to implementing an LPAR system, which of the following needs to be done?()A A graphics monitor must be attached to the serverB Cluster System Management (CSM) software must be installedC The LPAR system must have an Hardware Management Console (HMC) connectedD Each LPAR must be configured with a CDROM for operating system installation

考题 单选题In order for DLPAR operations to be possible, the RMC daemons on the Hardware Management Console (HMC) must communicate with the RMC daemons on all of the LPARs involved. How can the RMC daemons be restarted on the HMC, causing the least disruption?()A Run /usr/sbin/rsct/bin/rmcctrl z as hscroot. B Reboot the HMC, either through the GUI or via the command line. C Disable and re-enable RMC in the Firewall settings in the HMC GUI. D Select the Partition Communication checkbox in the LAN Adapter dialogue box.

考题 单选题Which of the following can deploy system plans generated by the IBM System Planning Tool (SPT)?()A  The Hardware Management Console (HMC) and Integrated Virtualization Manager (IVM).B  The Hardware Management Console (HMC) and Advanced System Manager Interface (ASMI).C  Integrated Virtualization Manager (IVM) and Advanced System Manager Interface (ASMI).D  Integrated Virtualization Manager (IVM) and BladeCenter Advanced Management Module (AMM).

考题 单选题Which one of these statements is true regarding hot pluggable PCIe and PCI-X slots in a Power 550?()A Cards can be added and then enabled via Hardware Management Console (HMC) GUI or command line. B The HMC allows access to the Advanced System Management Interface (ASMI), where the slots can be managed. C If the empty slot was already allocated to an LPAR, the LPAR can use the card after the cfgmgr script has been run. D The Hardware Management Console (HMC) GUI can guide a customer through the process of adding a card to an empty slot. 

考题 单选题Which of the following statements is true regarding implementing Live Partition Mobility on two existing POWER6 based systems?()A The systems must use internal storage for boot purposes. B All virtualized ethernet adapters must be numbered below 10. C The mobile partition's network and disk access must be virtualized. D Each system must be controlled by a different Hardware Management Console (HMC). 

考题 单选题A customer has 4 POWER6 servers managed by a Hardware Management Console (HMC). They plan to install a second HMC for redundancy.  Which of the following statements correctlydescribes the dual HMC environment? ()A  To provide the Service Agent function, both HMCs must have Service Agent enabled and a dedicated modem and phone line.B  Authorized users must have the same username and password on both HMCs, so that every user of one HMC is automatically authorized on the other.C  Both HMCs are automatically notified of any changes that occur in the managed systems, so results of changes made to the managed system by one HMC are visible on theD  Both HMCs must be running the same software revision. Software maintenance must be performed on both HMCs at the same time, but one HMC should be disconnected from

考题 单选题Which of the following interfaces is required to implement Workload Partition Mobility? ()A  Workload Partitions Manager for AIXB  Hardware Management Console (HMC) GUIC  Integrated Virtualization Manager (IVM)D  Advanced System Management Interface (ASMI)

考题 单选题Which of the following statements is true regarding implementing Live Partition Mobility on two existing POWER6 based systems? ()A  The systems must use internal storage for boot purposes.B  All virtualized Ethernet adapters must be numbered below 10.C  The mobile partition’s network and disk access must be virtualized.D  Each system must be controlled by a different Hardware Management Console (HMC).

考题 单选题On which HMC GUI panel can the ’Enable Electronic Service Agent’ option be found?()A HMC ManagementB Systems ManagementC Service ManagementD Electronic Management

考题 单选题Which of the following is a feature of Integrated Virtualization Manager (IVM)? ()A  It has a GUI interface for upgrading system firmware. B  It creates and manages AIX/Linux and VIOS type LPARs. C  It can be managed by the Hardware Management Console (HMC). D  It supports Live Partition Mobility on POWER6 systems and above.

考题 单选题An administrator wants to query the CPU resources of the managed system 9117-MMA*6512345 from the Hardware Management Console (HMC) command line.  Which of the following HMC commands could achieve this?()A  lssysres -r cpu -m 9117-MMA*6512345 -r sysB  lssyscfg -r proc -m 9117-MMA*6512345 -r sysC  lshwres -r proc -m 9117-MMA*6512345 --level sysD  lshwcfg -r proc -m 9117-MMA*6512345 --level sys