网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)

Cooling Water的中文含义是()。

  • A、冷却管
  • B、冷却水套
  • C、冷却水
  • D、冷却油

参考答案

更多 “Cooling Water的中文含义是()。A、冷却管B、冷却水套C、冷却水D、冷却油” 相关考题
考题 What is head tank in the closed cooling water system used for?A.for the release of air from the cooling waterB.providing expansion room for heated cooling waterC.a place for implementing water and water treatment agentD.all of the above

考题 High diesel engine cooling water temperatures can be caused by ______.A.air in the cooling systemB.an overhauled water pumpC.correct amount of coolantD.no air in the cooling system

考题 Why is it necessary to have routine testing of the cooling water?A.To ensure that the proper residuals of treatment chemicals, as specified, are maintained all timeB.To trace leakage in the cooling water systemC.It is not necessaryD.To detect the presence of contaminants in the water that may be injurious to the cooling system

考题 Cooling water pump

考题 名词解释题Cooling water pump

考题 单选题In a closed cooling water system, which of the problems can cause the water pressure to fluctuate?()A An open vent in the cooling systemB A fouled sea chestC A restricted water passage in the engineD Air entrained in the cooling water

考题 单选题The device allowing for the change in volume of the cooling water in a propulsion diesel engine closed cooling system is the ().A fresh water expansion tankB sea water expansion tankC thermostatic expansion valveD jacket water cooler accumulator

考题 单选题One of the purposes for water cooling the exhaust manifold in marine diesel engine is to ()A reduce lube oil temperatureB raise exhaust temperature reduceC excessive heating of engine roomD reduce load on cooling water pump

考题 单选题If the cooling water temperature and the lube oil temperature in a diesel engine are too high, the cause can be ()A a dirty lube oil strainerB internal water leaksC an oil suction line restrictionD excessive wears of the cooling water pump

考题 单选题When distilling sea water the cooling water discharging from the distiller is fed back to evaporator as feed water ().A to decrease scale formationB for better cooling effectC for more economical purposeD to raise vacuum

考题 单选题Why the cooling water of the diesel engine should be treated? Because the()A Cooling water is alkalescenceB cooling water is acidityC cooling water has salinityD cooling water has impurity

考题 单选题If the jacket water temperature in an auxiliary diesel engine cooling system is lower than normal, the probable cause is ()A air binding of the engine cooling systemB a cracked water cooled exhaust manifoldC blockage in the heat exchangerD faulty operation of the thermostat

考题 单选题Where is the cooling water from the compensating tank in the cooling water system of main engine lead to?()A discharge side of the centrifugal pumpB suction side of the centrifugal pumpC the lowest point of the cooling water systemD inlet of the main engine

考题 单选题High diesel engine cooling water temperatures can be caused by ().A air in the cooling systemB an overhauled water pumpC correct amount of coolantD no air in the cooling system

考题 单选题In a closed cooling system for a turbocharged, four-stroke/cycle diesel engine, fluctuating water pressure can be caused by ()A improper venting of the cooling systemB carrying the expansion tank water level too highC a totally clogged impeller in the cooling water pumpD an incorrectly set cooling system temperature control

考题 单选题Corrosion inhibitors and/or soluble oils are added to diesel engine cooling systems to ()A maintain low pH in the cooling waterB reduce the cooling water temperatureC increase cooling water hardnessD form a protective film on metal surfaces

考题 单选题When distilling salt water the cooling water discharging from the distiller is fed back to evaporator as feed water ().A to cut down the amount of cooling water neededB to prevent an excess amount of cooling water from being discharged to the bilgesC to supply hot water to the evaporator for more economical operationD None of the above is tree

考题 单选题Which of the following statements is correct concerning diesel engine cooling water systems?()A Each engine must have its own engine driven cooling water pump capable of providing cooling for all ranges of operationB propulsion engines with bores exceeding 200 mm are to be fitted with a means to display the cooling water temperature of each cylinderC At least two independent sea suctions are to be provided for supplying water to the engine jackets or to the heat exchangersD Suitable strain are to be fitted between the circulating pumps and heat exchangers when sea water is used for direct cooling

考题 单选题Which of the following statements is true concerning an oil cooler?()A The oil temperature is less than the cooling water temperatureB The oil pressure is less than the cooling water pressureC The oil pressure is greater than the cooling water pressureD The oil flow control valve is always installed in the oil input line

考题 单选题If the water level dropped rapidly in the expansion tank of a closed diesel engine cooling water system, you should suspect a ().A loss of suction in the circulating pumpB leak in the primary cooling systemC broken raw water pump shaftD burned or cracked piston in one cylinder

考题 单选题Which of the following problems can cause fluctuating pressures in the closed cooling system of a main propulsion diesel engine?()A Defective temperature controls in the systemB Cavitation in the cooling water pumpC Opened vent in the cooling systemD Restricted water passages in the engine

考题 单选题Temperature control valves installed in the jacket cooling water system of a diesel engine modulates the rate of water flow through the ().A cooling water pumpB nozzle cooling passagesC cylinder jacketsD heat exchanger

考题 单选题Which of the following statements is correct for the design and installation of diesel engine cooling water systems?()A An alarm device with audible and visible signals is required for all cooling water systemsB Propulsion engines with bores over 200 mm are to be fitted with cooling water jacketsC Each totally enclosed cooling system shall be provided with a suitable head tankD Drain cocks are to be provided at the lowest points of all cylinder water jackets

考题 单选题Which of the following may cause that excessively warm water leaves the condenser in a refrigeration plant? () (1) too little cooling water (2) too much cooling water (3) too warm cooler waterA (1)onlyB anyof(1),(2)and(3)C anyof(1)and(3)D anyof(1)and(2)

考题 单选题Which of the following conditions will develop if the flow of ‘raw’ cooling water to diesel engine is obstructed?()A Air will enter the cooling systemB Carbon will plug the water cooled exhaust manifoldsC The jacket water temperature will riseD The lube oil viscosity will increase

考题 单选题If the compressor-discharge temperature is higher than the receiver temperature()A increase the amount of cooling water to the condenserB decrease the amount of cooling water to the condenserC add more refrigerant to the systemD remove some of the refrigerant from the system

考题 单选题High diesel engine cooling water temperatures can be caused by ().A a worn water pumpB not enough coolantC air in the cooling systemD all of the above