网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
The heat removed from the refrigerant in the condenser of a refrigeration plant is the ()
A

latent heat of expansion

B

sensible heat of condensation

C

heat of compression

D

all of the above


参考答案

参考解析
解析: 暂无解析
更多 “单选题The heat removed from the refrigerant in the condenser of a refrigeration plant is the ()A latent heat of expansionB sensible heat of condensationC heat of compressionD all of the above” 相关考题
考题 Moisture is removed from a refrigeration system byA.bleeding refrigerant from the condenserB.opening a drain petcock on the oil separatorC.condensing the water in the heat exchangerD.using a dehydrator cartridge

考题 The temperature of the refrigerant in the evaporator coil depends mostly upon the ___.A.refrigerant pressure in the evaporatorB.cooling water temperature to the condenserC.heat load in the refrigerator compartmentD.solenoid valve in the liquid line

考题 If the superheat value of a thermostatic expansion valve is set too low, the _.A.the suction line will be abnormally cold and liquid may slug back to the compressorB.the suction line will be hot due to a reduced amount of refrigerant returning to the compressorC.the temperature of the refrigerant within the condenser will remain the sameD.the temperature of the refrigerant passing through the sub-cooler will decrease

考题 Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.

考题 The heat gained per pound of refrigerant in the evaporator is known as the ______.A.latent heat of vaporizationB.sensible heatC.refrigerating effectD.specific heat of vaporization

考题 单选题Low compressor head pressure in a refrigeration system can be caused by().A insufficient condenser cooling waterB excessive condenser cooling waterC air in the refrigeration systemD excessive refrigerant in the system

考题 单选题When the temperature of the refrigerant flowing out from the condenser is below the condensing temperature, it is said to be ().A dryB wetC super-cooledD superheated

考题 单选题Refrigerant enters the condenser as a ().A high pressure liquidB low pressure vaporC high pressure vaporD low pressure liquid

考题 单选题The refrigerant flows through the evaporator, where it () heat from the refrigerated space.A extractsB releasesC gives noD absorbs no

考题 单选题What is the purpose of sub cooling R-12 in the condenser?()A to increase the system efficiency by sensible heat transferB to stop the liquid from flashingC to reduce the load on the compressorD to remove latent heat of vaporization and the suction piping transfer

考题 单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().A compressor;condenserB condenser;evaporatorC throttle valve;evaporatorD evaporator;condenser

考题 单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().A compressorB condenserC receiverD evaporator

考题 单选题The heat removed from the refrigerant in the condenser of a refrigeration plant is the ()A latent heat of expansionB sensible heat of condensationC heat of compressionD all of the above

考题 单选题In a compression refrigeration plant the refrigerant flows from the expansion valve and through the () where it absorbs heat from the space being cooled and becomes a gas or vapor.A compressorB condenserC throttle valveD evaporator

考题 单选题Which of the following terms represents the form of heat removed from the refrigerant in the condenser of a refrigeration system?()A Latent heat of vaporizationB Heat of compressionC SuperheatD All of the above

考题 单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A maintain adequate coil back pressureB prohibit flashing in the liquid lineC reduce refrigerant volume in the systemD reduce compressor discharge line loading

考题 单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().A a shortage of compressor oilB warm food in the refrigeratorC excessive condenser cooling waterD a shortage of refrigerant

考题 单选题Moisture is removed from a refrigeration system by().A bleeding refrigerant from the condenserB opening a drain petcock on the oil separatorC condensing the water in the heat exchangerD using a dehydrator cartridge

考题 单选题The heat gained per pound of refrigerant in the evaporator is known as the().A latent heat of vaporizationB sensible heatC refrigerating effectD specific heat of vaporization

考题 单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A passing it through the expansion valveB condensing refrigerant in the system condenserC passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD maintaining a high pressure on the systems receiver

考题 单选题The purpose of the purge valve at the top of the condenser in a refrigerating system is to()A remove any air that may accumulate in the systemB take out unpleasant fumes from the refrigerantC vent off excess refrigerant in an emergencyD permit opening the refrigerating system for cleaning and inspecting

考题 单选题A condenser is a vessel in which() is deprived of its latent heat of vaporization and so changed to its liquid state.A sea waterB fresh waterC vapourD gas

考题 单选题Excessively warm water leaving condenser may be caused by()A fouled tubes in shell and tube condenserB too little or too warm condenser waterC air or non-condensable gas in systemD overcharge of refrigerant

考题 单选题A refrigerant gives up heat when it goes through ().A condenserB regurgitateC evaporatorD boil coil

考题 单选题Early models of the flash-type evaporators used a separate shell-and-tube heat exchanger as the air ejector condenser.More recent models use a combined air ejector condenser with the()A distilling condenserB salt water feed heaterC distillate coolerD flash chamber

考题 单选题The component of a refrigerating system in which the refrigerant vaporizes and absorbs heat is known as the ().A condenserB vapor generatorC accumulatorD evaporator

考题 单选题The thermostatic valve has a throttling action, that is to say the valve can()A stop the refrigerant from flowingB force the refrigerant to flowC cause the refrigerant pressure to riseD cause the refrigerant pressure to fall

考题 单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A change the expansion valve adjustmentB readjust the water regulating valve to increase the flow of waterC purge air from the condenserD clean the waterside of the condenser