网友您好, 请在下方输入框内输入要搜索的题目:
题目内容
(请给出正确答案)
单选题
Refrigerant enters the condenser as a ().
A
high pressure liquid
B
low pressure vapor
C
high pressure vapor
D
low pressure liquid
参考答案
参考解析
解析:
暂无解析
更多 “单选题Refrigerant enters the condenser as a ().A high pressure liquidB low pressure vaporC high pressure vaporD low pressure liquid” 相关考题
考题
()throttlestheliquidrefrigerantandmaintainsthepressuredifferencebetweenthecondenserandtheevaporator。
A、TheexpansionvalveB、CompressorC、EvaporatorD、Condenser
考题
Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?( )A.Shortage of refrigerant oilB.Slight shortage of refrigerantC.Excessive condenser cooling water flowD.Faulty expansion valve
考题
If the superheat value of a thermostatic expansion valve is set too low, the _.A.the suction line will be abnormally cold and liquid may slug back to the compressorB.the suction line will be hot due to a reduced amount of refrigerant returning to the compressorC.the temperature of the refrigerant within the condenser will remain the sameD.the temperature of the refrigerant passing through the sub-cooler will decrease
考题
Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.
考题
In a chilled(冷的) water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ______.A.increasing refrigerant pressure in the coilB.increasing chilled water flow through the coolerC.sub-cooling the refrigerant in the condenserD.superheating the refrigerant in the compressor
考题
I undertake to bring to the notice of the Suez Canal Authorities,before my vessel ______ the Canal,any defects which may appear.A.enters intoB.entersC.enters inD.enters to
考题
Fearing damage from either or both of the above incidents,the Master now ______ me this note of protest,reserving to himself the right to extend same at time and place convenient.A.entersB.enters intoC.enters withD.enters to
考题
单选题Low compressor head pressure in a refrigeration system can be caused by().A
insufficient condenser cooling waterB
excessive condenser cooling waterC
air in the refrigeration systemD
excessive refrigerant in the system
考题
单选题Which of the conditions listed will cause a refrigeration compressor to run constantly without simultaneously decreasing the temperature in the refrigerated space?()A
Shortage of refrigerant oilB
Slight shortage of refrigerantC
Excessive condenser cooling water flowD
Faulty expansion valve
考题
单选题As the refrigerant passes through the valve orifice, its pressure is reduced and part of the refrigerant turns into ().A
liquidB
oily mixtureC
emulsionD
vapor
考题
单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().A
compressor;condenserB
condenser;evaporatorC
throttle valve;evaporatorD
evaporator;condenser
考题
单选题In the condenser, the hot, high pressure refrigerant gas is cooled by the sea water and becomes().A
fresh waterB
vaporC
mixtureD
liquid
考题
单选题The heat removed from the refrigerant in the condenser of a refrigeration plant is the ()A
latent heat of expansionB
sensible heat of condensationC
heat of compressionD
all of the above
考题
单选题Which of the following terms represents the form of heat removed from the refrigerant in the condenser of a refrigeration system?()A
Latent heat of vaporizationB
Heat of compressionC
SuperheatD
All of the above
考题
单选题Refrigerant is normally sub-cooled in a refrigeration or air conditioning system condenser to ().A
maintain adequate coil back pressureB
prohibit flashing in the liquid lineC
reduce refrigerant volume in the systemD
reduce compressor discharge line loading
考题
单选题If a liquid sight flow indicator in a refrigeration system shows gas bubbles in motion passing inside of the glass, there is ().A
too much refrigerant in the systemB
oil entrained in the refrigerantC
less than a full charge of refrigerant in the systemD
ice crystals forming in the refrigerant
考题
单选题If the high-pressure switch on the compressor opens and stops the compressor a possible cause could be:()A
too much cooling water going through the condenserB
not enough refrigerant in the systemC
a leak in the evaporator coilsD
no enough cooling water going through the condenser
考题
单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().A
a shortage of compressor oilB
warm food in the refrigeratorC
excessive condenser cooling waterD
a shortage of refrigerant
考题
单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().A
passing it through the expansion valveB
condensing refrigerant in the system condenserC
passing the gaseous refrigerant through the heat interchanger on the suction side of the compressorD
maintaining a high pressure on the systems receiver
考题
单选题The purpose of the purge valve at the top of the condenser in a refrigerating system is to()A
remove any air that may accumulate in the systemB
take out unpleasant fumes from the refrigerantC
vent off excess refrigerant in an emergencyD
permit opening the refrigerating system for cleaning and inspecting
考题
单选题In a chilled water air conditioning unit using a reciprocating compressor, the refrigerating effect of the primary refrigerant can be increased by ().A
increasing refrigerant pressure in the coilB
increasing chilled water flow through the coolerC
sub-cooling the refrigerant in the condenserD
superheating the refrigerant in the compressor
考题
单选题Excessively warm water leaving condenser may be caused by()A
fouled tubes in shell and tube condenserB
too little or too warm condenser waterC
air or non-condensable gas in systemD
overcharge of refrigerant
考题
单选题Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().A
liquidB
dry saturated gasC
wet saturated gasD
superheated vapor
考题
单选题The thermostatic valve has a throttling action, that is to say the valve can()A
stop the refrigerant from flowingB
force the refrigerant to flowC
cause the refrigerant pressure to riseD
cause the refrigerant pressure to fall
考题
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().A
change the expansion valve adjustmentB
readjust the water regulating valve to increase the flow of waterC
purge air from the condenserD
clean the waterside of the condenser
考题
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().A
increase the amount of cooling water to the condenserB
decrease the amount of cooling water to the condenserC
add more refrigerant to the systemD
remove some refrigerant from the system
热门标签
最新试卷