In a closed cooling system for a turbocharged, four-stroke/cycle diesel engine, fluctuating water pressure can be caused by ()
A
improper venting of the cooling system
B
carrying the expansion tank water level too high
C
a totally clogged impeller in the cooling water pump
D
an incorrectly set cooling system temperature control
参考答案
参考解析
解析:
暂无解析
更多 “单选题In a closed cooling system for a turbocharged, four-stroke/cycle diesel engine, fluctuating water pressure can be caused by ()A improper venting of the cooling systemB carrying the expansion tank water level too highC a totally clogged impeller in the cooling water pumpD an incorrectly set cooling system temperature control” 相关考题
考题
What is head tank in the closed cooling water system used for?A.for the release of air from the cooling waterB.providing expansion room for heated cooling waterC.a place for implementing water and water treatment agentD.all of the above
考题
In a diesel engine closed freshwater cooling system, the amount of coolant flowing through the heat exchanger is controlled by the __.A.suction pressure regulatorB.thermostatic bypass valveC.sea water temperatureD.water level in the expansion tank
考题
Prolonged operation of a diesel engine with a closed cooling water system, at lower than normal designed operating temperatures can ______.A.increase power outputB.decrease lube oil viscosityC.eliminate fuel knockD.cause sulfuric acid formation
考题
Which of the following accurately describes the meaning of redundant cooling?()A、The source of cooling to a RAID systemB、The cooling system in a redundant power supplyC、A cooling system that can be installed in case of failureD、A second cooling system in case of a failure
考题
单选题If the coolant temperature of a closed cooling water system for a diesel engine gradually increases, the trouble usually is ()A
a broken shaft on the freshwater pumpB
an excessive accumulation of scale exchangerC
an incorrect thermostatic element operating rangeD
lube oil in the cooling water
考题
单选题The pH value of water in a diesel engine closed cooling water system should be maintained between ().A
60 to75B
80 to 95C
100 to 115D
120 to 135
考题
单选题What is head tank in the closed cooling water system used for?()A
for the release of air from the cooling waterB
providing expansion room for heated cooling waterC
a place for implementing water and water treatment agentD
all of the above
考题
单选题In the closed cooling system, the water ().A
is made to circulate out of the systemB
is made to circulate within the systemC
is made circulate within the systemD
is made circulate out of the system
考题
单选题The device allowing for the change in volume of the cooling water in a propulsion diesel engine closed cooling system is the ().A
fresh water expansion tankB
sea water expansion tankC
thermostatic expansion valveD
jacket water cooler accumulator
考题
单选题Typical marine propulsion plants include() directly coupled to the vessel’s single large-diameter, fixed-pitch propeller.A
a single, long-stroke, slow-speed, turbocharged, two-stroke diesel engineB
a single, long-stroke, medium-speed, turbocharged, four-stroke diesel engineC
two medium-speed, turbocharged, four-stroke diesel enginesD
a variable-speed AC generator
考题
单选题Performance of a turbocharged engine can be improved by()A
decreasing the amount of valve overlapB
preheating the air intakeC
after-cooling the intake airD
preheating light fuel
考题
单选题In a closed cooling system for a turbocharged, four-stroke/cycle diesel engine, fluctuating water pressure can be caused by ()A
improper venting of the cooling systemB
carrying the expansion tank water level too highC
a totally clogged impeller in the cooling water pumpD
an incorrectly set cooling system temperature control
考题
单选题The expansion tank for a diesel engine closed cooling system is designed to maintain a constant head on the system and ().A
reduce water temperatureB
reduce water turbulenceC
provide an air cushionD
allow for an increase in water volume as the engine warms up
考题
单选题The expansion tank in a diesel engine closed freshwater cooling system is located at ()A
the highest point in the systemB
the lowest point in the systemC
near the floorD
plate level or near the tank top level
考题
单选题The outlet from an expansion tank of a closed freshwater cooling system should be piped to the ().A
cylinder head water outlet headerB
cylinder jacket inlet mainC
heat exchanger inlet connectionD
jacket water pump suction line
考题
单选题The highest pressure in any closed diesel engine freshwater cooling system is at the ().A
jacket water outletB
expansion tank inletC
heat exchanger inletD
cooling water pump outlet
考题
单选题Which of the following accurately describes the meaning of redundant cooling?()A
The source of cooling to a RAID systemB
The cooling system in a redundant power supplyC
A cooling system that can be installed in case of failureD
A second cooling system in case of a failure
考题
单选题Clearance volume scavenging in a turbocharged, four-stroke/cycle diesel engine is accomplished ().A
during the valve overlap periodB
with only the exhaust valve openC
at a pressure below atmosphericD
without cooling the cylinders or pistons
考题
单选题As an alternative to the conventional seawater cooling system, is based on principles about cooler locations, ()flow control and preheating, but with a central cooler and one additional set of pumps().A
the central cooling system, differentB
the central cooling system, the sameC
the open cooling system, differentD
the open cooling system, the same
考题
单选题If the water level dropped rapidly in the expansion tank of a closed diesel engine cooling water system, you should suspect a ().A
loss of suction in the circulating pumpB
leak in the primary cooling systemC
broken raw water pump shaftD
burned or cracked piston in one cylinder
考题
单选题Which of the following problems can cause fluctuating pressures in the closed cooling system of a main propulsion diesel engine?()A
Defective temperature controls in the systemB
Cavitation in the cooling water pumpC
Opened vent in the cooling systemD
Restricted water passages in the engine
考题
单选题In a closed diesel engine freshwater cooling system, the amount of coolant flowing through the heat exchanger is controlled by the ().A
suction pressure regulatorB
thermostatic bypass valveC
sea water temperatureD
water level in the expansion tank
考题
单选题Operating a diesel engine for prolonged periods, with a closed freshwater cooling system, at temperatures lower than the normal design temperature can cause ().A
the formation of sulfuric acidB
a decrease in lube oil viscosityC
a decrease in cooling water pHD
a thermostat failure
考题
单选题In any diesel engine closed freshwater cooling system, the lowest pressure exists at the ().A
jacket water outletB
cooling water pump outletC
heat exchanger outletD
expansion tank atmospheric vent
考题
单选题A turbocharged, four-stroke/cycle diesel engine has a larger valve overlap than a naturally aspirated four-stroke/cycle diesel engine, in order to in crease the ().A
temperature of the exhaust gasesB
energy supplied to the turbochargerC
air pressure to the intake manifoldD
purge of exhausted gases from the cylinders
考题
单选题Turbocharged four-stroke/cycle diesel engines utilize valve overlap for().A
improving cylinder scavengingB
preheating the combustion chamberC
reducing air charge densityD
preventing valve wear
考题
单选题Scavenging in a turbocharged, four-stroke/cycle diesel engine is accomplished()A
during the valve overlap periodB
with only the exhaust valve openC
at a pressure below atmosphericD
without cooling the cylinders or pistons
考题
单选题A four-stroke cycle, turbocharged, 1000 horsepower diesel engine has been operating under loadThe load suddenly increases, causing excessive black exhaust smoke, and a rapid rise in the lube oil temperatureIn response to this condition, you should:()A
reduce loadB
check your exhaustC
adjust cooling water temperatureD
increase lube oil flow