网友您好, 请在下方输入框内输入要搜索的题目:

题目内容 (请给出正确答案)
单选题
When reentering an engine room that has been flooded with CO2, the investigating team should initially().
A

leave the access door partially open

B

enter from the lowest level

C

enter from the highest level

D

attempt to operate machinery


参考答案

参考解析
解析: 暂无解析
更多 “单选题When reentering an engine room that has been flooded with CO2, the investigating team should initially().A leave the access door partially openB enter from the lowest levelC enter from the highest levelD attempt to operate machinery” 相关考题
考题 When data() , it has to be analyzed to decide what it all means. A.had been collectedB.has collectedC.has been collected

考题 I’d like this room ________. A. is decoratedB. was decoratedC. has been decoratedD. to be decorated

考题 _____, water turns into ice.A、When freezingB、When frozenC、When it has been frozenD、When freezes to it

考题 When stand-by before sailing, the duty engineer and officer should check clock, engine telegraph and rudder, and then write it in the0 A.engine room logbookB.vovage logbookc engine room logbook or voyage loglookD.engine room logbook and voyage logbook

考题 What must be paid attention when watchkeeping in the engine room?

考题 when you do the watch keeping in the engine room ,what should you be careful about ?

考题 when do you have call the chief engineer to the engine room ?

考题 When oily ballast has been pumped overboard,an entry must be made in the ______.A.Oil Record BookB.Official LogbookC.deck rough logD.engine rough log

考题 A vessel is described as a two compartment vessel when it ______.A.has no more than two compartmentsB.has two compartments in addition to the engine roomC.will sink if any two compartments are floodedD.will float if any two adjacent compartments are flooded

考题 Before using a fixed CO2 system to fight an engine room fire, you must ______.A.secure the engine room ventilationB.secure the machinery in the engine roomC.evacuate all engine room personnelD.All of the above

考题 单选题Before using a fixed CO2 system to fight an engine room fire,you must().A secure the engine room ventilationB secure the machinery in the engine roomC evacuate all engine room personnelD All of the above

考题 单选题With UMS, when the engine room is unwatched () will control the main engine.A the bridge officer on watchB the chief engineerC the duty engineerD the duty motorman

考题 单选题The first the Second Mate knew of the fire was the sounding of the emergency alarm,which had been()from the engine room.A actedB activatedC actionedD enactioned

考题 单选题Leaking oil seals on a diesel engine turbocharger can cause()A the engine to run after the fuel has been securedB the engine to over-speedC a fireD all of the above

考题 单选题Hannah finished building her new all-purpose projects room last year, and she has been working in the room ever since.A and she has been working in the room ever sinceB and since that time she has worked thereC where always since she worksD she has been working in that room ever sinceE and since then is working there

考题 单选题Engine room fires have been started by neglected oil leaks dripping on to hot pipes or exhaust manifolds () insulation has not been replaced after maintenance.A whichB whenC whoseD what

考题 单选题The sludge tank installed in the diesel engine room is used to collect() Ⅰ.sludge from the fuel oil settling tanks ad centrifuge Ⅱ.water that has been collected in the settling tankA ⅠonlyB Ⅱ onlyC bothⅠand ⅡD neitherⅠor Ⅱ

考题 单选题When the general alarm is sounded continuously, the engine room personnel should ().A proceed to their man overboard stationsB start the fire pumpC put on lifejackets and go to their abandon ship stationsD secure the propulsion diesel engines and evacuate the engine room

考题 单选题Which of the following actions should be taken by the engine room watch when the general alarm is sounded continuously?()A The fire pump should be startedB The boiler rims should be securedC The fixed CO2 system should be initiated into actionD The engine room ventilation should be secured

考题 单选题In order to release CO2 to the machinery spaces from a fixed fire extinguishing system, you must().A actuate an alarm and open the engine room control valveB actuate an alarm and open the engine room CO2 releasing valveC open the engine room control valve and shut off engine room ventilation fansD open the engine room control valve and then the CO2 releasing valve

考题 单选题Under which of the listed conditions can the engine room retake the throttle control from the bridge().A Any time it is deemed necessaryB Only with the masters permissionC After a 10 minute delay to the input commandD Only after the throttle has been placed in stop

考题 单选题Lubricating oil should be changed on a heavy duty diesel engine when().A it gets dark in colorB a sample rubbed between fingers feels thinC it has been in use for a specified intervalD it no longer supports combustion

考题 单选题According to the ship emergency plan, when average accident happened and the captain made the decision to withdraw from the engine room before leaving the engine room, the wrong operation is that ()A the chief engineer leaves the engineer room with the engine room log book at firstB releasing compressed air in the air receiver and closing the watertight doorC stopping all the running machineries and electric devicesD closing the quick-closing valves of all the oil tanks, stopping the boiler and releasing gas

考题 单选题When stand-by before sailing, the duty engineer and officer should check clock, engine telegraph and rudder, and then write it in the ()A engine room logbookB voyage logbookC engine room logbook or voyage logbookD engine room logbook and voyage logbook

考题 单选题When accepting engine room spares, you should()A send a requisition list to the supplierB check that whether the items ordered have been already deliveredC make the chief engineer on sportD follow a preset procedure

考题 单选题When restarting a heavy fuel diesel engine that has been stopped for some time, the engine should()A increase the starting air pressureB use a higher than normal cranking speedC increase the fuel injection pressureD use a fuel having a lower ignition temperature

考题 单选题Your vessel is equipped with a fixed CO2 system and a fire main system. In the event of an electrical fire in the engine room what is the correct procedure for fighting the fire?()A Use the CO2 system and evacuate the engine roomB Use the fire main system and evacuate the engine roomC Evacuate the engine room and use the CO2 systemD Evacuate the engine room and use the fire main system