单选题
A combustible gas indicator meter is calibrated to read the percentage of().
A
vapor to oxygen
B
the flammable limit concentration
C
the autoignition concentration
D
the lower explosive limit concentretion
参考答案
参考解析
解析:
暂无解析
更多 “单选题A combustible gas indicator meter is calibrated to read the percentage of().A vapor to oxygenB the flammable limit concentrationC the autoignition concentrationD the lower explosive limit concentretion” 相关考题
考题
Before entering a fuel tank that has been cleaned, it should be checked with an oxygen indicator and a/an ____.A.Orsat apparatusB.flame safety lampC.Halide torchD.combustible gas indicator
考题
An inert gas system on a tanker should be used to ______.A.prevent the generation of flammable or combustible gas in tanksB.blow out cargo lines to prevent the build up of gas concentrationsC.dilute tank atmospheres to keep gas concentrations below the lower explosive limitD.prevent fires in the pumproom by continually displacing flammable vapors
考题
I hereby ______ that my vessel is fitted with a rudder angle indicator and an engine revolution indicator on the bridge in such a position that the pilot may read both without having to move away from his station; and that the rudder angle indicator and engine revolution indicator are in good working condition.A.delayB.stateC.deleteD.contain
考题
What is the best instrument for establishing a safe working area before welding in a confined space?A.An oxygen indicatorB.A combustible gas indicatorC.A combination combustible gas and oxygen indicatorD.A flame safety lamp
考题
What is used to test a tank for oxygen content ________.A.Combustible gas indicatorB.Vapor indicatorC.Atmosphere analyzer kitD.None of the above
考题
You are testing a tank that contained gasoline by using a combustible gas indicator.Under testing,the tank sample caused the needle to move rapidly to 100 on the dial then fall to zero.What is the concentration of flammable gas ________.A.Less than the flammable rangeB.Within the flammable rangeC.Over the flammable rangeD.The explosimeter is defective and giving a false reading
考题
Which statement is TRUE concerning combustible gas indicators ________.A.One sample of air is adequate to test a tankB.They do not work properly where there is a lack of oxygenC.They will detect a lack of oxygenD.They are calibrated to read the percentage chance of explosion
考题
An oxygen indicator can be used to determine if there is ______.A.sufficient oxygen in a compartment to support lifeB.combustible gases presentC.hyfrogen gases presentD.All of the above
考题
Combustible gas indicators measure the presence of combustible gas as a percentage of the____.A.flash pointB.upper explosive limitC.lower explosive limitD.fire point
考题
Deficient oxygen content inside a chain locker can be detected with ______.A.litmus paperB.a combustible gas indicatorC.an oxygen breathing apparatusD.an oxygen indicator
考题
单选题What is NOT a responsibility of the tankerman in charge of loading an unmanned tank barge? ()A
Enforcement of smoking restrictionsB
Restricting vessels from coming alongside the bargeC
Insuring that a combustible gas indicator is aboardD
Protecting cargo hose with chafing gear
考题
单选题A firemans outfit carried onboard cargo vessels, must have a ().A
canister-type gas maskB
fresh-air breathing apparatusC
self-contained breathing apparatusD
combustible gas indicator
考题
单选题A combustible gas indicator is used to determine ().A
if there is sufficient oxygen to support lifeB
the toxicity of flammable gases or vaporsC
the amount ofCO2 present in flue gasD
the presence of flammable gases or vapors in the air
考题
单选题AC voltmeters are generally calibrated to read the ()A
instantaneous voltageB
average voltageC
RMS voltageD
peak voltage
考题
单选题If the meter needle of the oxygen indicator cannot be set to zero,what should be done? ()A
Replace the batteriesB
Check the sampling tube for blockageC
Adjust the final reading by the amount the needle is displaced from zeroD
Replace the platinum filament
考题
单选题A pumproom is suspected of accumulating gases after a ventilation machinery breakdown. Where should the combustible gas indicator case be placed when testing the pumproom atmosphere for combustible gases? ()A
In the lower level of the pumproomB
In the middle level of the pumproomC
In the upper level of the pumproomD
On the deck outside the pumproom
考题
单选题Deficient oxygen content inside a chain locker can be detected with().A
litmus paperB
a combustible gas indicatorC
an oxygen breathing apparatusD
an oxygen indicator
考题
单选题Before entering a fuel tank that has been cleaned, it should be checked with an oxygen indicator and a/an().A
Orsat apparatusB
flame safety lampC
Halide torchD
combustible gas indicator
考题
单选题A combination combustible gas and oxygen indicator is an instrument that measures the() of both combustible gas and oxygen; each is indicated on a separate meter.A
purifiesB
combinationsC
concentrationsD
filters
考题
单选题Combustible gas indicators measure the presence of combustible gas as a percentage of the().A
flash pointB
upper explosive limitC
lower explosive limitD
fire point
考题
单选题A diesel engine crankcase ventilation system ()A
prevents spark generationB
removes combustible gasesC
determines the level of combustible gasesD
provides inert gas generation in crankcase
考题
单选题What can be used to measure the percentage of oxygen inside a chain locker?()A
Flame safety lampB
Combustible gas indicatorC
Oxygen indicatorD
H2S meter
考题
单选题Hydrocarbon vapors are usually detected by the use of the ().A
flame safety lampB
combustible gas indicatorC
gasometerD
oxygen indicator
考题
单选题Before entering a tank,always check the vapor content()a combustible gas indicator.A
withB
byC
ofD
for
考题
单选题An oxygen indicator can be used to determine if there is().A
sufficient oxygen in a compartment to support lifeB
combustible gases presentC
hydrogen gas presentD
All of the above
考题
单选题An inert gas system on a tanker should be used to().A
prevent the generation of flammable or combustible gas in tanksB
blow out cargo lines to prevent the build up of gas concentrationsC
dilute tank atmospheres to keep gas concentrations below the lower explosive limitD
prevent fires in the pumproom by continually displacing flammable vapors
考题
单选题An inert gas system on a tanker should be used to().A
prevent the generation of flammable or combustible gas in tanksB
blow out cargo lines to prevent gas concentrationsC
dilute tank atmospheres to keep gas concentrations below the lower explosive limitD
prevent fires in the pumproom by continually displacing flammable vapors