If the meter needle of the oxygen indicator cannot be set to zero,what should be done? ()
A

Replace the batteries

B

Check the sampling tube for blockage

C

Adjust the final reading by the amount the needle is displaced from zero

D

Replace the platinum filament


参考答案

参考解析
解析: 暂无解析
更多 “单选题If the meter needle of the oxygen indicator cannot be set to zero,what should be done? ()A Replace the batteriesB Check the sampling tube for blockageC Adjust the final reading by the amount the needle is displaced from zeroD Replace the platinum filament” 相关考题
考题 The “rudder adjustment” control on an autopilot steering stand is used to ______.A.align the rudder angle indicator with the true rudder angleB.set the number of degrees of rudder per degree of course errorC.set the departure from base course before actuating the rudderD.set the rate at which the rudder responds

考题 The( )in the injector will lift at a pre-set pressure which ensures that the fuelwill atomize once it enters the cylinder.A.needle valveB.nozzlesC.pistonD.spring

考题 Before entering a fuel tank that has been cleaned, it should be checked with an oxygen indicator and a/an ____.A.Orsat apparatusB.flame safety lampC.Halide torchD.combustible gas indicator

考题 When measuring the oxygen content of the cargo tanks prior to loading cargoes requiring vapor recovery,check it ______.A.one meter from the tank bottom and one meter below the tank topB.one half the ullage of the tank and one meter below the tank topC.one half the ullage of the tank and one meter above the tank bottomD.at three meter intervals from the tank top to the bottom

考题 While testing a cargo tank,your oxygen indicator reads 25% oxygen in the tank. You would then ______.A.enter the tank safelyB.suspect the accuracy of the readingC.ventilate the tankD.test for nitrogen

考题 If the meter needle of the oxygen indicator cannot be set to zero,what should be done ________.A.Replace the batteriesB.Check the sampling tube for blockageC.Adjust the final reading by the amount the needle is displaced from zeroD.Replace the platinum filament

考题 Which statement concerning carbon dioxide is FALSE ________.A.It displaces the oxygen in the airB.It cannot be seenC.It cannot be smelledD.It is safe to use near personnel in a confined space

考题 What could result in an incorrect oxygen concentration reading on the oxygen indicator ________.A.Exposure to carbon dioxide for no more than 1 minuteB.Exposure to carbon dioxide for more than 10 minutesC.Exposure to a very low concentration of sulfur dioxide for no more than 2 minutesD.None of the above

考题 After each reading of an oxygen indicator, the instrument should be purged with ______.A.CO2B.fresh airC.the tested compartment’s airD.Water

考题 An oxygen indicator can be used to determine if there is ______.A.sufficient oxygen in a compartment to support lifeB.combustible gases presentC.hyfrogen gases presentD.All of the above

考题 Deficient oxygen content inside a chain locker can be detected with ______.A.litmus paperB.a combustible gas indicatorC.an oxygen breathing apparatusD.an oxygen indicator

考题 Which of the following would you use to enable automatic media recovery for a database?()A、SET AUTORECOVERY ONB、SET RECOVERY ONC、SET AUTO OND、You cannot enable automatic media recovery.

考题 单选题When measuring the oxygen content of the cargo tanks prior to loading cargoes requiring vapor recovery,check it().A one meter from the tank bottom and one meter below the tank topB one half the ullage of the tank and one meter below the tank topC one half the ullage of the tank and one meter above the tank bottomD at three meter intervals from the tank top to the bottom

考题 单选题A combustible gas indicator meter is calibrated to read the percentage of().A vapor to oxygenB the flammable limit concentrationC the autoignition concentrationD the lower explosive limit concentretion

考题 单选题A combustible gas indicator is used to determine ().A if there is sufficient oxygen to support lifeB the toxicity of flammable gases or vaporsC the amount ofCO2 present in flue gasD the presence of flammable gases or vapors in the air

考题 单选题When checking the oxygen content of the cargo tanks prior to loading cargoes requiring vapor recovery,the atmosphere must be sampled().A one meter from the tank bottom and one meter below the tank topB one half the ullage of the tank and one meter below the tank topC one half the ullage of the tank and one meter above the tank bottomD at three meter intervals from the tank top

考题 单选题Before a tank is to be crude oil washed,the oxygen content in the tank must be measured at a position().A immediately above the level of the oilB at the top of the tankC in the vent riserD one meter from the deck

考题 单选题The needle valve in the injector () at a pre-set pressure which ensures that the fuel will atomize once it enters the cylinder.A will liftB will be liftedC will closeD will be closed

考题 单选题Deficient oxygen content inside a chain locker can be detected with().A litmus paperB a combustible gas indicatorC an oxygen breathing apparatusD an oxygen indicator

考题 单选题Before entering a fuel tank that has been cleaned, it should be checked with an oxygen indicator and a/an().A Orsat apparatusB flame safety lampC Halide torchD combustible gas indicator

考题 单选题A combination combustible gas and oxygen indicator is an instrument that measures the() of both combustible gas and oxygen; each is indicated on a separate meter.A purifiesB combinationsC concentrationsD filters

考题 单选题GM cannot be used as an indicator of stability at all angles of inclination because().A M is not fixed at large anglesB there is no M at large anglesC G is not fixed at large anglesD there is no G at large angles

考题 单选题What can be used to measure the percentage of oxygen inside a chain locker?()A Flame safety lampB Combustible gas indicatorC Oxygen indicatorD H2S meter

考题 单选题An oxygen indicator will detect ().A the amount of oxygen in a spaceB the presence of harmful amounts of carbon monoxideC concentrations of explosive gasD All of the above

考题 单选题After each reading of an oxygen indicator,the instrument should be purged with().A CO2B fresh airC the tested compartment's airD water

考题 单选题While testing a cargo tank,your oxygen indicator reads 25% oxygen in the tank. You would then ().A enter the tank safelyB suspect the accuracy of the readingC ventilate the tankD test for nitrogen

考题 单选题Deficient oxygen content inside a chain locker can be detected with().A litmus paperB combustible gas indicatorC oxygen breathing apparatusD oxygen indicator