If the meter needle of the oxygen indicator cannot be set to zero,what should be done? ()
A
Replace the batteries
B
Check the sampling tube for blockage
C
Adjust the final reading by the amount the needle is displaced from zero
D
Replace the platinum filament
参考答案
参考解析
解析:
暂无解析
更多 “单选题If the meter needle of the oxygen indicator cannot be set to zero,what should be done? ()A Replace the batteriesB Check the sampling tube for blockageC Adjust the final reading by the amount the needle is displaced from zeroD Replace the platinum filament” 相关考题
考题
The “rudder adjustment” control on an autopilot steering stand is used to ______.A.align the rudder angle indicator with the true rudder angleB.set the number of degrees of rudder per degree of course errorC.set the departure from base course before actuating the rudderD.set the rate at which the rudder responds
考题
The( )in the injector will lift at a pre-set pressure which ensures that the fuelwill atomize once it enters the cylinder.A.needle valveB.nozzlesC.pistonD.spring
考题
Before entering a fuel tank that has been cleaned, it should be checked with an oxygen indicator and a/an ____.A.Orsat apparatusB.flame safety lampC.Halide torchD.combustible gas indicator
考题
When measuring the oxygen content of the cargo tanks prior to loading cargoes requiring vapor recovery,check it ______.A.one meter from the tank bottom and one meter below the tank topB.one half the ullage of the tank and one meter below the tank topC.one half the ullage of the tank and one meter above the tank bottomD.at three meter intervals from the tank top to the bottom
考题
While testing a cargo tank,your oxygen indicator reads 25% oxygen in the tank. You would then ______.A.enter the tank safelyB.suspect the accuracy of the readingC.ventilate the tankD.test for nitrogen
考题
If the meter needle of the oxygen indicator cannot be set to zero,what should be done ________.A.Replace the batteriesB.Check the sampling tube for blockageC.Adjust the final reading by the amount the needle is displaced from zeroD.Replace the platinum filament
考题
Which statement concerning carbon dioxide is FALSE ________.A.It displaces the oxygen in the airB.It cannot be seenC.It cannot be smelledD.It is safe to use near personnel in a confined space
考题
What could result in an incorrect oxygen concentration reading on the oxygen indicator ________.A.Exposure to carbon dioxide for no more than 1 minuteB.Exposure to carbon dioxide for more than 10 minutesC.Exposure to a very low concentration of sulfur dioxide for no more than 2 minutesD.None of the above
考题
After each reading of an oxygen indicator, the instrument should be purged with ______.A.CO2B.fresh airC.the tested compartment’s airD.Water
考题
An oxygen indicator can be used to determine if there is ______.A.sufficient oxygen in a compartment to support lifeB.combustible gases presentC.hyfrogen gases presentD.All of the above
考题
Deficient oxygen content inside a chain locker can be detected with ______.A.litmus paperB.a combustible gas indicatorC.an oxygen breathing apparatusD.an oxygen indicator
考题
Which of the following would you use to enable automatic media recovery for a database?()A、SET AUTORECOVERY ONB、SET RECOVERY ONC、SET AUTO OND、You cannot enable automatic media recovery.
考题
单选题When measuring the oxygen content of the cargo tanks prior to loading cargoes requiring vapor recovery,check it().A
one meter from the tank bottom and one meter below the tank topB
one half the ullage of the tank and one meter below the tank topC
one half the ullage of the tank and one meter above the tank bottomD
at three meter intervals from the tank top to the bottom
考题
单选题A combustible gas indicator meter is calibrated to read the percentage of().A
vapor to oxygenB
the flammable limit concentrationC
the autoignition concentrationD
the lower explosive limit concentretion
考题
单选题A combustible gas indicator is used to determine ().A
if there is sufficient oxygen to support lifeB
the toxicity of flammable gases or vaporsC
the amount ofCO2 present in flue gasD
the presence of flammable gases or vapors in the air
考题
单选题When checking the oxygen content of the cargo tanks prior to loading cargoes requiring vapor recovery,the atmosphere must be sampled().A
one meter from the tank bottom and one meter below the tank topB
one half the ullage of the tank and one meter below the tank topC
one half the ullage of the tank and one meter above the tank bottomD
at three meter intervals from the tank top
考题
单选题Before a tank is to be crude oil washed,the oxygen content in the tank must be measured at a position().A
immediately above the level of the oilB
at the top of the tankC
in the vent riserD
one meter from the deck
考题
单选题The needle valve in the injector () at a pre-set pressure which ensures that the fuel will atomize once it enters the cylinder.A
will liftB
will be liftedC
will closeD
will be closed
考题
单选题Deficient oxygen content inside a chain locker can be detected with().A
litmus paperB
a combustible gas indicatorC
an oxygen breathing apparatusD
an oxygen indicator
考题
单选题Before entering a fuel tank that has been cleaned, it should be checked with an oxygen indicator and a/an().A
Orsat apparatusB
flame safety lampC
Halide torchD
combustible gas indicator
考题
单选题A combination combustible gas and oxygen indicator is an instrument that measures the() of both combustible gas and oxygen; each is indicated on a separate meter.A
purifiesB
combinationsC
concentrationsD
filters
考题
单选题GM cannot be used as an indicator of stability at all angles of inclination because().A
M is not fixed at large anglesB
there is no M at large anglesC
G is not fixed at large anglesD
there is no G at large angles
考题
单选题What can be used to measure the percentage of oxygen inside a chain locker?()A
Flame safety lampB
Combustible gas indicatorC
Oxygen indicatorD
H2S meter
考题
单选题An oxygen indicator will detect ().A
the amount of oxygen in a spaceB
the presence of harmful amounts of carbon monoxideC
concentrations of explosive gasD
All of the above
考题
单选题After each reading of an oxygen indicator,the instrument should be purged with().A
CO2B
fresh airC
the tested compartment's airD
water
考题
单选题While testing a cargo tank,your oxygen indicator reads 25% oxygen in the tank. You would then ().A
enter the tank safelyB
suspect the accuracy of the readingC
ventilate the tankD
test for nitrogen
考题
单选题Deficient oxygen content inside a chain locker can be detected with().A
litmus paperB
combustible gas indicatorC
oxygen breathing apparatusD
oxygen indicator